Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: current status and recommendations for clinical implementation L Beaulieu, Å Carlsson Tedgren, JF Carrier, SD Davis, F Mourtada, ... Medical physics 39 (10), 6208-6236, 2012 | 551 | 2012 |
Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization ÅK Carlsson, P Andreo, A Brahme Physics in Medicine & Biology 42 (6), 1033, 1997 | 109 | 1997 |
The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy ÅK Carlsson, A Ahnesjö Medical physics 27 (10), 2320-2332, 2000 | 88 | 2000 |
Lineal energy and radiation quality in radiation therapy: model calculations and comparison with experiment L Lindborg, M Hultqvist, ÅC Tedgren, H Nikjoo Physics in medicine & Biology 58 (10), 3089, 2013 | 85 | 2013 |
A generic high‐dose rate 192Ir brachytherapy source for evaluation of model‐based dose calculations beyond the TG‐43 formalism F Ballester, Å Carlsson Tedgren, D Granero, A Haworth, F Mourtada, ... Medical physics 42 (6Part1), 3048-3062, 2015 | 83 | 2015 |
On the Monte Carlo simulation of small-field micro-diamond detectors for megavoltage photon dosimetry P Andreo, H Palmans, M Marteinsdóttir, H Benmakhlouf, ... Physics in Medicine & Biology 61 (1), L1, 2015 | 66 | 2015 |
Point kernels and superposition methods for scatter dose calculations in brachytherapy ÅK Carlsson, A Ahnesjö Physics in Medicine & Biology 45 (2), 357, 2000 | 63 | 2000 |
Accounting for high Z shields in brachytherapy using collapsed cone superposition for scatter dose calculation ÅK Carlsson Tedgren, A Ahnesjö Medical Physics 30 (8), 2206-2217, 2003 | 59 | 2003 |
Brachytherapy source characterization for improved dose calculations using primary and scatter dose separation KR Russell, ÅK Carlsson Tedgren, A Ahnesjö Medical physics 32 (9), 2739-2752, 2005 | 56 | 2005 |
Response of LiF: Mg, Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (< 1 MeV) ÅC Tedgren, A Hedman, JE Grindborg, GA Carlsson Medical physics 38 (10), 5539-5550, 2011 | 54 | 2011 |
Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy Å Carlsson Tedgren, A Ahnesjö Medical physics 35 (4), 1611-1618, 2008 | 49 | 2008 |
A generic TG‐186 shielded applicator for commissioning model‐based dose calculation algorithms for high‐dose‐rate 192Ir brachytherapy Y Ma, J Vijande, F Ballester, ÅC Tedgren, D Granero, A Haworth, ... Medical physics 44 (11), 5961-5976, 2017 | 48 | 2017 |
On the biological basis for competing macroscopic dose descriptors for kilovoltage dosimetry: cellular dosimetry for brachytherapy and diagnostic radiology RM Thomson, ÅC Tedgren, JF Williamson Physics in Medicine & Biology 58 (4), 1123, 2013 | 47 | 2013 |
Segmentation of bones in medical dual-energy computed tomography volumes using the 3D U-Net JCG Sánchez, M Magnusson, M Sandborg, ÅC Tedgren, A Malusek Physica medica 69, 241-247, 2020 | 43 | 2020 |
Evaluation of a lithium formate EPR dosimetry system for dose measurements around brachytherapy sources L Antonovic, H Gustafsson, G Alm Carlsson, Å Carlsson Tedgren Medical physics 36 (6Part1), 2236-2247, 2009 | 42 | 2009 |
Influence of phantom material and dimensions on experimental dosimetry ÅC Tedgren, GA Carlsson Medical physics 36 (6Part1), 2228-2235, 2009 | 37 | 2009 |
Collapsed cone dose calculations for heterogeneous tissues in brachytherapy using primary and scatter separation source data A Ahnesjö, B van Veelen, ÅC Tedgren Computer methods and programs in biomedicine 139, 17-29, 2017 | 36 | 2017 |
Impact of using linear optimization models in dose planning for HDR brachytherapy Å Holm, T Larsson, Å Carlsson Tedgren Medical physics 39 (2), 1021-1028, 2012 | 36 | 2012 |
Specification of absorbed dose to water using model-based dose calculation algorithms for treatment planning in brachytherapy ÅC Tedgren, GA Carlsson Physics in Medicine & Biology 58 (8), 2561, 2013 | 35 | 2013 |
Radiation dose measurements with alanine/agarose gel and thin alanine films around a 192Ir brachytherapy source, using ESR spectroscopy S Olsson, ES Bergstrand, ÅK Carlsson, EO Hole, E Lund Physics in Medicine & Biology 47 (8), 1333, 2002 | 35 | 2002 |