Structure and function of cholera toxin and the related Escherichia coli heat-labile enterotoxin BD Spangler Microbiological reviews 56 (4), 622-647, 1992 | 1204 | 1992 |
The three-dimensional crystal structure of cholera toxin RG Zhang, DL Scott, ML Westbrook, S Nance, BD Spangler, GG Shipley, ... Journal of molecular biology 251 (4), 563-573, 1995 | 486 | 1995 |
Comparison of the Spreeta® surface plasmon resonance sensor and a quartz crystal microbalance for detection of Escherichia coli heat-labile enterotoxin BD Spangler, EA Wilkinson, JT Murphy, BJ Tyler Analytica Chimica Acta 444 (1), 149-161, 2001 | 131 | 2001 |
Binding to native proteins by antipeptide monoclonal antibodies. BD Spangler Journal of immunology (Baltimore, Md.: 1950) 146 (5), 1591-1595, 1991 | 91 | 1991 |
Capture agents for a quartz crystal microbalance-continuous flow biosensor: functionalized self-assembled monolayers on gold BD Spangler, BJ Tyler Analytica Chimica Acta 399 (1-2), 51-62, 1999 | 76 | 1999 |
Quantitative prediction of two-photon absorption cross section based on linear spectroscopic properties A Rebane, NS Makarov, M Drobizhev, B Spangler, ES Tarter, BD Reeves, ... The Journal of Physical Chemistry C 112 (21), 7997-8004, 2008 | 57 | 2008 |
Kinetics of thermal electrocyclic ring closure. Alkyl-1, 3, 5-hexatrienes CW Spangler, TP Jondahl, B Spangler The Journal of Organic Chemistry 38 (14), 2478-2484, 1973 | 55 | 1973 |
Comparison of antibody− antigen interactions on collagen measured by conventional immunological techniques and atomic force microscopy R Avci, M Schweitzer, RD Boyd, J Wittmeyer, A Steele, J Toporski, I Beech, ... Langmuir 20 (25), 11053-11063, 2004 | 52 | 2004 |
Biosensors utilizing dendrimer-immobilized ligands and there use thereof BD Spangler, CW Spangler US Patent 7,138,121, 2006 | 48 | 2006 |
Crystallization of isoelectrically homogeneous cholera toxin BD Spangler, EM Westbrook Biochemistry 28 (3), 1333-1340, 1989 | 33 | 1989 |
Dendritic structures of poly (ethylene glycol) on silicon nitride and gold surfaces Z Suo, FT Arce, R Avci, K Thieltges, B Spangler Langmuir 22 (8), 3844-3850, 2006 | 17 | 2006 |
Cation absorption by baker's yeast as a passive process JE Leggett, RA Olsen, BD Spangler Proceedings of the National Academy of Sciences 48 (11), 1949-1956, 1962 | 12 | 1962 |
Hydrophobic binding of pertussis toxin is enhanced by oligosaccharide receptors BD Spangler, LD Heerze, CG Clark, GD Armstrong Archives of biochemistry and biophysics 305 (1), 153-158, 1993 | 11 | 1993 |
Evaluation of small-scale quartz-crystal microbalance and surface-plasmon-resonance biosensors for detection of bacterial pathogens. BD Spangler, EA Wilkinson ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY 219, U115-U115, 2000 | 10 | 2000 |
Design and synthesis of dendritic tethers for the immobilization of antibodies for the detection of class a bioterror pathogens. CW Spangler, BD Spangler, ES Tarter, ZY Suo ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY 227, U464-U464, 2004 | 9 | 2004 |
Methods in molecular biology and protein chemistry: cloning and characterization of an enterotoxin subunit BD Spangler (No Title), 2002 | 9* | 2002 |
Construction, DNA binding, two-dimensional nuclear magnetic resonance spectrum, and structure of a mutant lac repressor headpiece C Karslake, P Wisniowski, BD Spangler, AC Moulin, PL Wang, ... Journal of the American Chemical Society 113 (10), 4003-4005, 1991 | 7 | 1991 |
Isolation of isoelectrically pure cholera toxin for crystallization BD Spangler, EM Westbrook Journal of crystal growth 110 (1-2), 220-227, 1991 | 4 | 1991 |
High affinity polyvalent nanoether SAMs on gold: Why more is better [J] BD Spangler, ES Tarter, BD Reeves, Z Suo Material Matters 1 (2), 15-20, 2006 | 3 | 2006 |
A portable, rapid biosensor for pathogenic agents. BD Spangler, DS Ballantine ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY 213, 33-BTEC, 1997 | 2 | 1997 |