关注
SHUFALI ASHRAF WANI
SHUFALI ASHRAF WANI
Institute Post Doctoral Fellow at Department of Electrcial Engineering, IIT Madras
在 st.jmi.ac.in 的电子邮件经过验证
标题
引用次数
引用次数
年份
Advances in DGA based condition monitoring of transformers: A review
SA Wani, AS Rana, S Sohail, O Rahman, S Parveen, SA Khan
Renewable and Sustainable Energy Reviews 149, 111347, 2021
912021
Multiple incipient fault classification approach for enhancing the accuracy of dissolved gas analysis (DGA)
SA Wani, D Gupta, MU Farooque, SA Khan
IET Science, Measurement & Technology 13 (7), 959-967, 2019
512019
An MIP-based novel capacitive sensor to detect 2-FAL concentration in transformer oil
MDM Nezami, SA Wani, SA Khan, N Khera, S Sohail
IEEE Sensors Journal 18 (19), 7924-7931, 2018
362018
Fault severity determination in transformers using dissolved gas analysis (DGA)
SA Wani, MU Farooque, SA Khan, D Gupta, MA Khan
2015 Annual IEEE India Conference (INDICON), 1-6, 2015
252015
Smart diagnosis of incipient faults using dissolved gas analysis-based fault interpretation matrix (FIM)
SA Wani, SA Khan, G Prashal, D Gupta
Arabian Journal for Science and Engineering 44, 6977-6985, 2019
242019
Artificial neural network (ANN) based implementation of Duval pentagon
MU Farooque, SA Wani, SA Khan
2015 International Conference on Condition Assessment Techniques in …, 2015
232015
Diagnosis of incipient dominant and boundary faults using composite DGA method
SA Wani, SA Khan, D Gupta, MM Nezami
International Transactions on Electrical Energy Systems 27 (11), e2421, 2017
212017
A comb-type capacitive 2-FAL sensor for transformer oil with improved sensitivity
MM Nezami, SA Wani, SA Khan, N Khera, S Sohail
IEEE Transactions on Instrumentation and Measurement 69 (7), 4524-4532, 2019
202019
Fuzzy approach for residual life assessment of paper insulation
MM Nezami, SA Wani, SA Khan, N Khera, MA Khan
2017 3rd International Conference on Condition Assessment Techniques in …, 2017
152017
A capacitive sensor for detecting insulation degradation by sensing 2-FAL in transformer oil
SA Wani, MM Nezami, SA Khan, S Sohail
IEEE Transactions on Dielectrics and Electrical Insulation 27 (6), 2179-2187, 2020
122020
Performance enhancement and extension of DGA-based transformer fault diagnosis methods using soft-computing techniques
SA Khan, MA Khan, SA Wani, MD Equbal
Soft Computing in Condition Monitoring and Diagnostics of Electrical and …, 2020
62020
Measurement of Moisture in Transformer Insulation Using the Intelligent High-Frequency Sensor System
SA Wani, A Murugan, R Sarathi, V Subramanian
IEEE Transactions on Instrumentation and Measurement 72, 1-10, 2023
22023
Fuzzy based condition monitoring tool for real-time analysis of synthetic ester fluid as transformer insulant
SA Wani, AJ Amalanathan, R Sarathi
IEEE Access 10, 18055-18064, 2022
22022
Understanding the Surface Discharge activity with Nano oil-pressboard Insulation under AC and Lightning impulse voltages
BST Reddy, SA Wani, SK Amizhtan, C Naresh, R Sarathi
IEEE Transactions on Dielectrics and Electrical Insulation, 2023
12023
An improved dissolved gas analysis technique for incipient fault detection
SA Wani, SA Khan, Y Vikram, C Bhasker, S Perneen, D Gupta
2017 3rd International Conference on Condition Assessment Techniques in …, 2017
12017
Design and Implementation of Low-Cost PMU for Off-Nominal Frequency and DDC in Compliance with IEEE C37. 118 Standard
AS Rana, K Jnaneswar, MK Gadhiraju, N Kumar, SA Wani, MS Thomas
Distributed Generation & Alternative Energy Journal, 519-546, 2023
2023
Estimation of Fault Location Using Cyber Physical System in WAMCP
AS Rana, SA Wani, N Parveen, MS Thomas
Internet of Energy Handbook, 139-157, 2021
2021
Design and Analysis of a Cost-Effective Standalone Solar: Diesel Hybrid Power System
F Iqbal, AS Rana, SA Wani
Handbook of Research on Power and Energy System Optimization, 552-570, 2018
2018
Transformer fault diagnosis Based on Dissolved Gas Analysis DGA
SA Wani
Delhi, 0
系统目前无法执行此操作,请稍后再试。
文章 1–19