3D Slicer as an image computing platform for the Quantitative Imaging Network A Fedorov, R Beichel, J Kalpathy-Cramer, J Finet, JC Fillion-Robin, ... Magnetic resonance imaging 30 (9), 1323-1341, 2012 | 5770 | 2012 |
Engineering and algorithm design for an image processing API: a technical report on ITK-the insight toolkit TS Yoo, MJ Ackerman, WE Lorensen, W Schroeder, V Chalana, ... Medicine Meets Virtual Reality 02/10, 586-592, 2002 | 821 | 2002 |
Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction SR Aylward, E Bullitt IEEE transactions on medical imaging 21 (2), 61-75, 2002 | 806 | 2002 |
Measuring tortuosity of the intracerebral vasculature from MRA images E Bullitt, G Gerig, SM Pizer, W Lin, SR Aylward IEEE transactions on medical imaging 22 (9), 1163-1171, 2003 | 449 | 2003 |
Systems and methods for tubular object processing SR Aylward, E Bullitt, SM Pizer, D Fritsch US Patent 6,690,816, 2004 | 298 | 2004 |
Vessel tortuosity and brain tumor malignancy: a blinded study1 E Bullitt, D Zeng, G Gerig, S Aylward, S Joshi, JK Smith, W Lin, MG Ewend Academic radiology 12 (10), 1232-1240, 2005 | 293 | 2005 |
Image processing algorithms for digital mammography: a pictorial essay ED Pisano, EB Cole, BM Hemminger, MJ Yaffe, SR Aylward, ... Radiographics 20 (5), 1479-1491, 2000 | 235 | 2000 |
Systems, methods, and computer program products for analysis of vessel attributes for diagnosis, disease staging, and surgical planning E Bullitt, S Aylward US Patent 8,090,164, 2012 | 227 | 2012 |
Intensity ridge and widths for tubular object segmentation and description S Aylward, E Bullitt, S Pizer, D Eberly Proceedings of the Workshop on Mathematical Methods in Biomedical Image …, 1996 | 227 | 1996 |
Methods, systems, and computer program products for hierarchical registration between a blood vessel and tissue surface model for a subject and a blood vessel and tissue … S Aylward, E Bullitt, J Jomier US Patent 8,233,681, 2012 | 194 | 2012 |
Registration and analysis of vascular images SR Aylward, J Jomier, S Weeks, E Bullitt International journal of computer vision 55, 123-138, 2003 | 151 | 2003 |
Neuroimaging of structural pathology and connectomics in traumatic brain injury: Toward personalized outcome prediction A Irimia, B Wang, SR Aylward, MW Prastawa, DF Pace, G Gerig, ... NeuroImage: Clinical 1 (1), 1-17, 2012 | 142 | 2012 |
The effects of healthy aging on intracerebral blood vessels visualized by magnetic resonance angiography E Bullitt, D Zeng, B Mortamet, A Ghosh, SR Aylward, W Lin, BL Marks, ... Neurobiology of aging 31 (2), 290-300, 2010 | 134 | 2010 |
Mapping microvasculature with acoustic angiography yields quantifiable differences between healthy and tumor-bearing tissue volumes in a rodent model RC Gessner, SR Aylward, PA Dayton Radiology 264 (3), 733-740, 2012 | 124 | 2012 |
Quantification of microvascular tortuosity during tumor evolution using acoustic angiography SE Shelton, YZ Lee, M Lee, E Cherin, FS Foster, SR Aylward, PA Dayton Ultrasound in medicine & biology 41 (7), 1896-1904, 2015 | 115 | 2015 |
Radiologists’ preferences for digital mammographic display ED Pisano, EB Cole, S Major, S Zong, BM Hemminger, KE Muller, ... Radiology 216 (3), 820-830, 2000 | 110 | 2000 |
The image-guided surgery toolkit IGSTK: an open source C++ software toolkit A Enquobahrie, P Cheng, K Gary, L Ibanez, D Gobbi, F Lindseth, Z Yaniv, ... Journal of digital imaging 20, 21-33, 2007 | 109 | 2007 |
Neuroimaging in human immunodeficiency virus infection KA Tucker, KR Robertson, W Lin, JK Smith, H An, Y Chen, SR Aylward, ... Journal of neuroimmunology 157 (1-2), 153-162, 2004 | 108 | 2004 |
Analyzing attributes of vessel populations E Bullitt, KE Muller, I Jung, W Lin, S Aylward Medical image analysis 9 (1), 39-49, 2005 | 104 | 2005 |
Symbolic description of intracerebral vessels segmented from magnetic resonance angiograms and evaluation by comparison with X-ray angiograms E Bullitt, S Aylward, K Smith, S Mukherji, M Jiroutek, K Muller Medical Image Analysis 5 (2), 157-169, 2001 | 99 | 2001 |