Association of competitive and recreational sport participation with cardiac events in patients with arrhythmogenic right ventricular cardiomyopathy: results from the North … AC Ruwald, F Marcus, NAM Estes III, M Link, S McNitt, B Polonsky, ... European heart journal 36 (27), 1735-1743, 2015 | 324 | 2015 |
Left ventricular ejection fraction normalization in cardiac resynchronization therapy and risk of ventricular arrhythmias and clinical outcomes: results from the Multicenter … MH Ruwald, SD Solomon, E Foster, V Kutyifa, AC Ruwald, S Sherazi, ... Circulation 130 (25), 2278-2286, 2014 | 180 | 2014 |
Mortality reduction in relation to implantable cardioverter defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy … AC Ruwald, C Schuger, AJ Moss, V Kutyifa, B Olshansky, H Greenberg, ... Circulation: Arrhythmia and Electrophysiology 7 (5), 785-792, 2014 | 129 | 2014 |
Association between myocardial substrate, implantable cardioverter defibrillator shocks and mortality in MADIT-CRT N Sood, ACH Ruwald, S Solomon, JP Daubert, S McNitt, B Polonsky, ... European heart journal 35 (2), 106-115, 2014 | 76 | 2014 |
The association between biventricular pacing and cardiac resynchronization therapy-defibrillator efficacy when compared with implantable cardioverter defibrillator on outcomes … AC Ruwald, V Kutyifa, MH Ruwald, S Solomon, JP Daubert, C Jons, ... European heart journal 36 (7), 440-448, 2015 | 70 | 2015 |
Effect of metoprolol versus carvedilol on outcomes in MADIT-CRT (multicenter automatic defibrillator implantation trial with cardiac resynchronization therapy) MH Ruwald, ACH Ruwald, C Jons, J Alexis, S McNitt, W Zareba, AJ Moss Journal of the American College of Cardiology 61 (14), 1518-1526, 2013 | 61 | 2013 |
Syncope in high-risk cardiomyopathy patients with implantable defibrillators: frequency, risk factors, mechanisms, and association with mortality: results from the Multicenter … MH Ruwald, K Okumura, T Kimura, K Aonuma, M Shoda, V Kutyifa, ... Circulation 129 (5), 545-552, 2014 | 57 | 2014 |
Association between frequency of atrial and ventricular ectopic beats and biventricular pacing percentage and outcomes in patients with cardiac resynchronization therapy MH Ruwald, S Mittal, AC Ruwald, MK Aktas, JP Daubert, S McNitt, ... Journal of the American College of Cardiology 64 (10), 971-981, 2014 | 55 | 2014 |
Impact of carvedilol and metoprolol on inappropriate implantable cardioverter-defibrillator therapy: the MADIT-CRT trial (Multicenter Automatic Defibrillator Implantation With … MH Ruwald, A Abu-Zeitone, C Jons, AC Ruwald, S McNitt, V Kutyifa, ... Journal of the American College of Cardiology 62 (15), 1343-1350, 2013 | 55 | 2013 |
The impact of co‐morbidity burden on appropriate implantable cardioverter defibrillator therapy and all‐cause mortality: insight from Danish nationwide clinical registers AC Ruwald, M Vinther, GH Gislason, JB Johansen, JC Nielsen, ... European journal of heart failure 19 (3), 377-386, 2017 | 51 | 2017 |
Clinical impact, safety, and efficacy of single‐versus dual‐coil ICD leads in MADIT‐CRT V Kutyifa, AC HUTH RUWALD, MK Aktas, C Jons, S McNITT, B Polonsky, ... Journal of cardiovascular electrophysiology 24 (11), 1246-1252, 2013 | 44 | 2013 |
New-onset atrial fibrillation predicts malignant arrhythmias in post–myocardial infarction patients—a Cardiac Arrhythmias and RIsk Stratification after acute Myocardial … ACH Ruwald, PEB Thomsen, U Gang, RM Jørgensen, HV Huikuri, C Jons American Heart Journal 166 (5), 855-863. e3, 2013 | 43 | 2013 |
The effect of ICD programming on inappropriate and appropriate ICD Therapies in ischemic and nonischemic cardiomyopathy: the MADIT‐RIT trial K Sedláček, AC RUWALD, V Kutyifa, S Mcnitt, PEB Thomsen, H Klein, ... Journal of cardiovascular electrophysiology 26 (4), 424-433, 2015 | 42 | 2015 |
Digoxin therapy and associated clinical outcomes in the MADIT-CRT trial AY Lee, V Kutyifa, MH Ruwald, S McNitt, B Polonsky, W Zareba, AJ Moss, ... Heart Rhythm 12 (9), 2010-2017, 2015 | 41 | 2015 |
Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator … MH Ruwald, W Zareba, C Jons, C Zhang, ACH Ruwald, B Olshansky, ... Circulation 128 (7), 694-701, 2013 | 35 | 2013 |
Frequency of inappropriate therapy in patients implanted with dual‐versus single‐chamber ICD devices in the ICD arm of MADIT‐CRT ACH RUWALD, N Sood, MH Ruwald, C Jons, CA Clyne, S McNitt, ... Journal of Cardiovascular Electrophysiology 24 (6), 672-679, 2013 | 35 | 2013 |
Evaluation of the CHADS2 Risk Score on Short‐ and Long‐Term All‐Cause and Cardiovascular Mortality After Syncope MH Ruwald, AC Ruwald, C Jons, M Lamberts, ML Hansen, M Vinther, ... Clinical Cardiology 36 (5), 262-268, 2013 | 34 | 2013 |
The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter … AC Ruwald, G Pietrasik, I Goldenberg, V Kutyifa, JP Daubert, MH Ruwald, ... Journal of the American College of Cardiology 63 (12), 1190-1197, 2014 | 32 | 2014 |
Predictors of spontaneous reverse remodeling in mild heart failure patients with left ventricular dysfunction A Brenyo, A Barsheshet, V Kutyifa, AC Ruwald, M Rao, W Zareba, ... Circulation: Heart Failure 7 (4), 565-572, 2014 | 31 | 2014 |
Relation of QRS duration to clinical benefit of cardiac resynchronization therapy in mild heart failure patients without left bundle branch block: the multicenter automatic … Y Biton, V Kutyifa, I Cygankiewicz, I Goldenberg, H Klein, S McNitt, ... Circulation: Heart Failure 9 (2), e002667, 2016 | 29 | 2016 |