关注
Lane C Sander
标题
引用次数
引用次数
年份
Analysis of polycyclic aromatic hydrocarbons (PAHs) in environmental samples: a critical review of gas chromatographic (GC) methods
DL Poster, MM Schantz, LC Sander, SA Wise
Analytical and bioanalytical chemistry 386, 859-881, 2006
4912006
Development of engineered stationary phases for the separation of carotenoid isomers
LC Sander, KE Sharpless, NE Craft, SA Wise
Analytical Chemistry 66 (10), 1667-1674, 1994
4711994
Synthesis and characterization of polymeric C18 stationary phases for liquid chromatography
LC Sander, SA Wise
Analytical Chemistry 56 (3), 504-510, 1984
4561984
Selection of column and gradient elution system for the separation of catechins in green tea using high-performance liquid chromatography
JJ Dalluge, BC Nelson, JB Thomas, LC Sander
Journal of chromatography A 793 (2), 265-274, 1998
2791998
Recent advances in bonded phases for liquid chromatography
LC Sander, SA Wise, CH Lochmüller
Taylor & Francis Group 18 (4), 299-417, 1987
2741987
Factors affecting the reversed‐phase liquid chromatographic separation of polycyclic aromatic hydrocarbon isomers
SA Wise, LC Sander
Journal of High Resolution Chromatography 8 (5), 248-255, 1985
2671985
Fourier transform infrared spectrometric determination of alkyl chain conformation on chemically bonded reversed-phase liquid chromatography packings
LC Sander, JB Callis, LR Field
Analytical Chemistry 55 (7), 1068-1075, 1983
2661983
Capability of a polymeric C30 stationary phase to resolve cis-trans carotenoid isomers in reversed-phase liquid chromatography
C Emenhiser, LC Sander, SJ Schwartz
Journal of Chromatography A 707 (2), 205-216, 1995
2651995
Determination of polycyclic aromatic hydrocarbons by liquid chromatography
SA Wise, LC Sander, WE May
Journal of Chromatography A 642 (1-2), 329-349, 1993
2601993
Effect of phase length on column selectivity for the separation of polycyclic aromatic hydrocarbons by reversed-phase liquid chromatography
LC Sander, SA Wise
Analytical chemistry 59 (18), 2309-2313, 1987
2581987
C30 stationary phases for the analysis of food by liquid chromatography
LC Sander, KE Sharpless, M Pursch
Journal of Chromatography A 880 (1-2), 189-202, 2000
2112000
Shape selectivity in reversed-phase liquid chromatography for the separation of planar and non-planar solutes
LC Sander, SA Wise
Journal of Chromatography A 656 (1-2), 335-351, 1993
2111993
Influence of stationary phase chemistry on shape recognition in liquid chromatography
LC Sander, SA Wise
Analytical Chemistry 67 (18), 3284-3292, 1995
2001995
Subambient temperature modification of selectivity in reversed-phase liquid chromatography
LC Sander, SA Wise
Analytical Chemistry 61 (15), 1749-1754, 1989
1951989
Shape selectivity for constrained solutes in reversed-phase liquid chromatography
LC Sander, M Pursch, SA Wise
Analytical chemistry 71 (21), 4821-4830, 1999
1941999
Combined use of temperature and solvent strength in reversed-phase gradient elution I. Predicting separation as a function of temperature and gradient conditions
PL Zhu, LR Snyder, JW Dolan, NM Djordjevic, DW Hill, LC Sander, ...
Journal of chromatography A 756 (1-2), 21-39, 1996
1941996
Separation of Geometrical Carotenoid Isomers in Biological Extracts Using a Polymeric C30 Column in Reversed-Phase Liquid Chromatography
C Emenhiser, N Simunovic, LC Sander, SJ Schwartz
Journal of Agricultural and Food Chemistry 44 (12), 3887-3893, 1996
1891996
Development and certification of a standard reference material for vitamin D metabolites in human serum
KW Phinney, M Bedner, SSC Tai, VV Vamathevan, LC Sander, ...
Analytical chemistry 84 (2), 956-962, 2012
1742012
Column selectivity in reversed-phase liquid chromatography: III. The physico-chemical basis of selectivity
NS Wilson, JW Dolan, LR Snyder, PW Carr, LC Sander
Journal of Chromatography A 961 (2), 217-236, 2002
1742002
Influence of substrate parameters on column selectivity with alkyl bonded-phase sorbents
LC Sander, SA Wise
Journal of Chromatography A 316, 163-181, 1984
1621984
系统目前无法执行此操作,请稍后再试。
文章 1–20