Automated cortical projection of EEG sensors: anatomical correlation via the international 10–10 system L Koessler, L Maillard, A Benhadid, JP Vignal, J Felblinger, H Vespignani, ... Neuroimage 46 (1), 64-72, 2009 | 582 | 2009 |
The standardized EEG electrode array of the IFCN M Seeck, L Koessler, T Bast, F Leijten, C Michel, C Baumgartner, B He, ... Clinical neurophysiology 128 (10), 2070-2077, 2017 | 458 | 2017 |
Source localization of ictal epileptic activity investigated by high resolution EEG and validated by SEEG L Koessler, C Benar, L Maillard, JM Badier, JP Vignal, F Bartolomei, ... Neuroimage 51 (2), 642-653, 2010 | 141 | 2010 |
Focal electrical intracerebral stimulation of a face-sensitive area causes transient prosopagnosia J Jonas, M Descoins, L Koessler, S Colnat-Coulbois, M Sauvée, M Guye, ... Neuroscience 222, 281-288, 2012 | 130 | 2012 |
Catching the invisible: mesial temporal source contribution to simultaneous EEG and SEEG recordings L Koessler, T Cecchin, S Colnat-Coulbois, JP Vignal, J Jonas, ... Brain topography 28, 5-20, 2015 | 118 | 2015 |
Spatial localization of EEG electrodes L Koessler, L Maillard, A Benhadid, JP Vignal, M Braun, H Vespignani Neurophysiologie Clinique/Clinical Neurophysiology 37 (2), 97-102, 2007 | 109 | 2007 |
Correlation of invasive EEG and scalp EEG G Ramantani, L Maillard, L Koessler Seizure 41, 196-200, 2016 | 105 | 2016 |
In‐vivo measurements of human brain tissue conductivity using focal electrical current injection through intracerebral multicontact electrodes L Koessler, S Colnat‐Coulbois, T Cecchin, J Hofmanis, JP Dmochowski, ... Human brain mapping 38 (2), 974-986, 2017 | 98 | 2017 |
Seizure lateralization in scalp EEG using Hjorth parameters T Cecchin, R Ranta, L Koessler, O Caspary, H Vespignani, L Maillard Clinical neurophysiology 121 (3), 290-300, 2010 | 98 | 2010 |
Optimal use of EEG recordings to target active brain areas with transcranial electrical stimulation JP Dmochowski, L Koessler, AM Norcia, M Bikson, LC Parra Neuroimage 157, 69-80, 2017 | 79 | 2017 |
Electrical source imaging in cortical malformation–related epilepsy: A prospective EEG‐SEEG concordance study E Rikir, L Koessler, M Gavaret, F Bartolomei, S Colnat‐Coulbois, ... Epilepsia 55 (6), 918-932, 2014 | 79 | 2014 |
Simultaneous subdural and scalp EEG correlates of frontal lobe epileptic sources G Ramantani, M Dümpelmann, L Koessler, A Brandt, ... Epilepsia 55 (2), 278-288, 2014 | 75 | 2014 |
Intracerebral electrical stimulation of a face-selective area in the right inferior occipital cortex impairs individual face discrimination J Jonas, B Rossion, J Krieg, L Koessler, S Colnat-Coulbois, H Vespignani, ... NeuroImage 99, 487-497, 2014 | 73 | 2014 |
Intracranial evaluation of the epileptogenic zone in regional infrasylvian polymicrogyria G Ramantani, L Koessler, S Colnat‐Coulbois, JP Vignal, J Isnard, ... Epilepsia 54 (2), 296-304, 2013 | 60 | 2013 |
EEG–MRI Co-registration and sensor labeling using a 3D laser scanner L Koessler, T Cecchin, O Caspary, A Benhadid, H Vespignani, L Maillard Annals of Biomedical Engineering 39, 983-995, 2011 | 59 | 2011 |
The inferior occipital gyrus is a major cortical source of the face‐evoked N170: Evidence from simultaneous scalp and intracerebral human recordings C Jacques, J Jonas, L Maillard, S Colnat‐Coulbois, L Koessler, B Rossion Human brain mapping 40 (5), 1403-1418, 2019 | 57 | 2019 |
Right hemispheric dominance of visual phenomena evoked by intracerebral stimulation of the human visual cortex J Jonas, S Frismand, JP Vignal, S Colnat‐Coulbois, L Koessler, ... Human brain mapping 35 (7), 3360-3371, 2014 | 52 | 2014 |
Giant cystic widening of Virchow-Robin spaces: an anatomofunctional study J Mathias, L Koessler, H Brissart, S Foscolo, E Schmitt, S Bracard, ... American journal of neuroradiology 28 (8), 1523-1525, 2007 | 52 | 2007 |
Combined SEEG and source localisation study of temporal lobe schizencephaly and polymicrogyria L Maillard, L Koessler, S Colnat-Coulbois, JP Vignal, V Louis-Dorr, ... Clinical Neurophysiology 120 (9), 1628-1636, 2009 | 51 | 2009 |
Evaluating dipolar source localization feasibility from intracerebral SEEG recordings V Caune, R Ranta, S Le Cam, J Hofmanis, L Maillard, L Koessler, ... NeuroImage 98, 118-133, 2014 | 50 | 2014 |