Rapid analysis of melamine in infant formula by sweeping-micellar electrokinetic chromatography IL Tsai, SW Sun, HW Liao, SC Lin, CH Kuo Journal of Chromatography A 1216 (47), 8296-8303, 2009 | 88 | 2009 |
A pilot study of bevacizumab combined with etoposide and cisplatin in breast cancer patients with leptomeningeal carcinomatosis PF Wu, CH Lin, CH Kuo, WW Chen, DC Yeh, HW Liao, SM Huang, ... BMC cancer 15, 1-7, 2015 | 67 | 2015 |
Development of a general method for quantifying IgG-based therapeutic monoclonal antibodies in human plasma using protein G purification coupled with a two internal standard … HH Chiu, HW Liao, YY Shao, YS Lu, CH Lin, IL Tsai, CH Kuo Analytica chimica acta 1019, 93-102, 2018 | 58 | 2018 |
Sensitive screening of abused drugs in dried blood samples using ultra-high-performance liquid chromatography-ion booster-quadrupole time-of-flight mass spectrometry D Chepyala, IL Tsai, HW Liao, GY Chen, HC Chao, CH Kuo Journal of Chromatography a 1491, 57-66, 2017 | 47 | 2017 |
Enhanced single-cell metabolomics by capillary electrophoresis electrospray ionization-mass spectrometry with field amplified sample injection HW Liao, SS Rubakhin, MC Philip, JV Sweedler Analytica chimica acta 1118, 36-43, 2020 | 45 | 2020 |
Analysis of peptide stereochemistry in single cells by capillary electrophoresis–trapped ion mobility spectrometry mass spectrometry DH Mast, HW Liao, EV Romanova, JV Sweedler Analytical chemistry 93 (15), 6205-6213, 2021 | 40 | 2021 |
Rapid and sensitive determination of posaconazole in patient plasma by capillary electrophoresis with field-amplified sample stacking HW Liao, SW Lin, UI Wu, CH Kuo Journal of Chromatography A 1226, 48-54, 2012 | 36 | 2012 |
Metabolomic analysis of complex Chinese remedies: examples of induced nephrotoxicity in the mouse from a series of remedies containing aristolochic acid DM Tsai, JJ Kang, SS Lee, SY Wang, IL Tsai, GY Chen, HW Liao, ... Evidence‐Based Complementary and Alternative Medicine 2013 (1), 263757, 2013 | 28 | 2013 |
Using a postcolumn-infused internal standard for correcting the matrix effects of urine specimens in liquid chromatography–electrospray ionization mass spectrometry HW Liao, GY Chen, IL Tsai, CH Kuo Journal of Chromatography A 1327, 97-104, 2014 | 27 | 2014 |
Using precursor ion scan of 184 with liquid chromatography-electrospray ionization-tandem mass spectrometry for concentration normalization in cellular lipidomic studies HC Chao, GY Chen, LC Hsu, HW Liao, SY Yang, SY Wang, YL Li, ... Analytica chimica acta 971, 68-77, 2017 | 26 | 2017 |
Estimation and correction of the blood volume variations of dried blood spots using a postcolumn infused-internal standard strategy with LC-electrospray ionization-MS HW Liao, SW Lin, GY Chen, CH Kuo Analytical chemistry 88 (12), 6457-6464, 2016 | 25 | 2016 |
Using water plug-assisted analyte focusing by micelle collapse in combination with microemulsion electrokinetic chromatography for analyzing phthalate esters HC Chao, HW Liao, CH Kuo Journal of Chromatography A 1445, 149-157, 2016 | 21 | 2016 |
Improved dried blood spot-based metabolomics analysis by a postcolumn infused-internal standard assisted liquid chromatography-electrospray ionization mass spectrometry method D Chepyala, HC Kuo, KY Su, HW Liao, SY Wang, SR Chepyala, ... Analytical chemistry 91 (16), 10702-10712, 2019 | 18 | 2019 |
Identification of potential sphingomyelin markers for the estimation of hematocrit in dried blood spots via a lipidomic strategy HW Liao, SW Lin, YT Lin, CH Lee, CH Kuo Analytica Chimica Acta 1003, 34-41, 2018 | 18 | 2018 |
Development of a postcolumn infused-internal standard liquid chromatography mass spectrometry method for quantitative metabolomics studies HW Liao, GY Chen, MS Wu, WC Liao, CH Lin, CH Kuo Journal of Proteome Research 16 (2), 1097-1104, 2017 | 18 | 2017 |
Bioequivalence and in vitro antimicrobial activity between generic and brand-name levofloxacin HY Sun, HW Liao, MH Sheng, HM Tai, CH Kuo, WH Sheng Diagnostic Microbiology and Infectious Disease 85 (3), 347-351, 2016 | 18 | 2016 |
A matrix-induced ion suppression method to normalize concentration in urinary metabolomics studies using flow injection analysis electrospray ionization mass spectrometry G Chen, H Liao, YJ Tseng, I Tsai, C Kuo Analytica chimica acta 864, 21-29, 2015 | 17 | 2015 |
Quantification of endogenous metabolites by the postcolumn infused-internal standard method combined with matrix normalization factor in liquid chromatography–electrospray … HW Liao, GY Chen, MS Wu, WC Liao, IL Tsai, CH Kuo Journal of Chromatography A 1375, 62-68, 2015 | 15 | 2015 |
Quantification of target analytes in various biofluids using a postcolumn infused-internal standard method combined with matrix normalization factors in liquid chromatography … HW Liao, IL Tsai, GY Chen, YS Lu, CH Lin, CH Kuo Journal of Chromatography A 1358, 85-92, 2014 | 14 | 2014 |
Using the PCI-IS method to simultaneously estimate blood volume and quantify nonvitamin K antagonist oral anticoagulant concentrations in dried blood spots RS Jhang, SY Lin, YF Peng, HC Chao, IL Tsai, YT Lin, HW Liao, SC Tang, ... Analytical chemistry 92 (3), 2511-2518, 2020 | 13 | 2020 |