Moisture in cellulose insulation of power transformers-statistics J Gielniak, A Graczkowski, H Moranda, P Przybylek, K Walczak, ... IEEE Transactions on Dielectrics and Electrical Insulation 20 (3), 982-987, 2013 | 66 | 2013 |
Location of partial discharge sources in power transformers based on advanced auscultatory technique W Sikorski, K Siodla, H Moranda, W Ziomek IEEE Transactions on Dielectrics and Electrical Insulation 19 (6), 1948-1956, 2012 | 65 | 2012 |
Can the bubble effect occur in an oil impregnated paper bushing? P Przybylek, H Moranda, K Walczak, H Moscicka-Grzesiak IEEE Transactions on Dielectrics and Electrical Insulation 19 (6), 1879-1883, 2012 | 26 | 2012 |
Dielectric frequency response of cellulose samples with various degree of moisture content and aging K Walczak, A Graczkowski, J Gielniak, H Morańda, H Mościcka-Grzesiak, ... Przegląd Elektrotechniczny 1, 264-267, 2006 | 20 | 2006 |
Application of synthetic ester for drying distribution transformer insulation - The influence of cellulose thickness on drying efficiency P Przybylek, H Moranda, H Moscicka-Grzesiak, D Szczesniak Energies 12 (20), 3874-1 - 3874-16, 2019 | 16 | 2019 |
Oil resistance at different phases of bridge mechanism development at direct voltage M Ossowski, J Gielniak, H Moranda, H Grzesiak-Moscicka XIII International Symposium on High Voltage Engineering Netherlands - XIII …, 2003 | 15 | 2003 |
Oil resistance at different phases of bridge mechanism development at direct voltage M Ossowski, J Gielniak, H Moranda, H Moscicka-Grzesiak 11 International Workshop on High Voltage Engineering - HVE 2002 Workshop …, 2002 | 15 | 2002 |
Influence of thermal ageing on dielectric response of oil-paper insulation J Gielniak, A Graczkowski, S Gubanski, H Moranda, H Moscicka-Grzesiak, ... Materials Science-Poland 27 (4/2), 1199-1205, 2009 | 14 | 2009 |
Comparative Tests of Partial Discharges in Nomex® 910 Paper and Cellulose Paper H Moranda, H Moscicka-Grzesiak, P Przybylek, K Walczak, R Szewczyk Energies 13 (3), 647-1 - 647-8, 2020 | 12 | 2020 |
Dynamics of bridge creating in contaminated oil at AC voltage and analysis of accompanying partial discharges H Moranda, K Walczak, H Moscicka-Grzesiak XIII International Symposium on High Voltage Engineering Netherlands - XIII …, 2003 | 12 | 2003 |
The bubble effect in bushings–investigations on models P Przybylek, H Moranda, K Walczak, H Moscicka-Grzesiak IEEE Transactions on Dielectrics and Electrical Insulation 22 (6), 3405-3412, 2015 | 11 | 2015 |
Program do analizy odpowiedzi częstotliwościowej (FDS) dielektryków H Morańda, M Koch Przegląd Elektrotechniczny–Konferencje, 156-162, 2006 | 11 | 2006 |
System monitoringu wyladowan niezupelnych metoda emisji akustycznej – doswiadczenia eksploatacyjne W Sikorski, K Walczak, H Moranda, W Gil, M Andrzejewski Przegląd Elektrotechniczny 88 (11b'2012), 117-121, 2012 | 10* | 2012 |
Enlargement of fingerprint in procedure of defects recognition in oil-paper insulation using time parameters of PD H Moranda, M Sztolcman, K Walczak, H Moscicka-Grzesiak 14 International Symposium on High Voltage Engineering, ISH 2005, Beijing …, 2005 | 10 | 2005 |
Laboratory model studies on the drying efficiency of transformer cellulose insulation using synthetic ester P Przybylek, H Moranda, H Moscicka-Grzesiak, M Cybulski Energies 13 (13), 3467-1 - 3467-11, 2020 | 9 | 2020 |
Detekcja, identyfikacja i lokalizacja źródeł wyładowań niezupełnych w transformatorze energetycznym W Sikorski, H Morańda, B Bródka, R Neumann Przegląd Elektrotechniczny 86 (11b), 142-145, 2010 | 8* | 2010 |
Analiza FDS w ocenie zawilgocenia izolacji transformatorów K Walczak, J Gielniak, A Graczkowski, H Morańda Pomiary Automatyka Kontrola 54 (10), 727-729, 2008 | 8 | 2008 |
Warunki wystąpienia „bubble effect” w transformatorze o izolacji papierowo-olejowej J Gielniak, H Moranda, S Neumann, M Ossowski, P Przybylek, K Walczak, ... Energetyka - Zeszyt tematyczny nr VI, 2005 | 8 | 2005 |
Wykrywanie zwarc zwojowych w transformatorze energetycznym przy uzyciu metody SFRA K Lewandowski, H Moranda Przeglad Elektrotechniczny 94 (10'2018), 118-121, 2018 | 7* | 2018 |
Experimental Validation of a Method of Drying Cellulose Insulation in Distribution Transformers Using Circulating Synthetic Ester P Przybylek, Walczak, S Krzysztof, Wojciech, H Moscicka-Grzesiak, ... IEEE Access 9, 150322-150329, 2021 | 6 | 2021 |