A prototype of aerial radiation monitoring system using an unmanned helicopter mounting a GAGG scintillator Compton camera J Jiang, K Shimazoe, Y Nakamura, H Takahashi, Y Shikaze, Y Nishizawa, ... Journal of Nuclear Science and Technology 53 (7), 1067-1075, 2016 | 112 | 2016 |
Field test around Fukushima Daiichi nuclear power plant site using improved Ce:Gd3(Al,Ga)5O12 scintillator Compton camera mounted on an unmanned helicopter Y Shikaze, Y Nishizawa, Y Sanada, T Torii, J Jiang, K Shimazoe, ... Journal of Nuclear Science and Technology 53 (12), 1907-1918, 2016 | 50 | 2016 |
A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner J Jiang, K Li, Q Wang, K Puterbaugh, JW Young, SB Siegel, JA O'Sullivan, ... Medical physics 46 (9), 4165-4176, 2019 | 19 | 2019 |
Augmented whole-body scanning via magnifying PET J Jiang, S Samanta, K Li, SB Siegel, RA Mintzer, S Cho, M Conti, ... IEEE transactions on medical imaging 39 (11), 3268-3277, 2019 | 14 | 2019 |
Feasibility study of a point‐of‐care positron emission tomography system with interactive imaging capability J Jiang, K Li, S Komarov, JA O'Sullivan, YC Tai Medical physics 46 (4), 1798-1813, 2019 | 11 | 2019 |
Performance comparison of a dedicated total breast PET system with a clinical whole-body PET system: a simulation study S Samanta, J Jiang, M Hamdi, AZ Register, S Majewski, MB Williams, ... Physics in Medicine & Biology 66 (11), 115004, 2021 | 9 | 2021 |
Synthesis and Preclinical Evaluation of Novel 99mTc-Labeled FAPI-46 Derivatives with Significant Tumor Uptake and Improved Tumor-to-Nontarget Ratios Q Ruan, D Ding, L Diao, J Feng, G Yin, Y Jiang, Q Wang, P Han, J Jiang, ... Journal of Medicinal Chemistry 67 (4), 3190-3202, 2024 | 8 | 2024 |
High sensitivity dedicated dual-breast PET/MR imaging: concept and preliminary simulations MP Tornai, S Samanta, S Majewski, MB Williams, TG Turkington, ... 15th International Workshop on Breast Imaging (IWBI2020) 11513, 323-328, 2020 | 4 | 2020 |
Synthesis and Evaluation of 99mTc-Labelled 2-Nitroimidazole Derivatives with Different Linkers for Tumour Hypoxia Imaging Q Ruan, Y Liu, L Liao, J Hao, Y Jiang, J Jiang, J Zhang Pharmaceuticals 16 (9), 1276, 2023 | 3 | 2023 |
A novel Compton camera with an annular absorber for enhancing the imaging efficiency in regions directly ahead: A simulation study Z Yuan, D Xue, H Yang, H Liu, J Hua, H Wang, J Jiang Journal of Nuclear Science and Technology 60 (10), 1208-1218, 2023 | 2 | 2023 |
A virtual-pinhole PET device for improving contrast recovery and enhancing lesion detectability of a one-meter-long PET scanner: a simulation study J Jiang, J Hua, H Wang, Z Yuan, Y Meng, H Lu, S Liu, Y Chen, YC Tai Physics in Medicine & Biology 68 (14), 145011, 2023 | 1 | 2023 |
Point-of-Care PET/Ultrasound Imaging for Detection of Atherosclerotic Vulnerable Plaque: A Feasibility Study S Samanta, J Jiang, D Ye, M Hutchinson, Y Zeng, S Li, X Zhang, Y Liu, ... Journal of Nuclear Medicine 61 (supplement 1), 310-310, 2020 | 1 | 2020 |
Development of a simultaneous PET/Ultrasound imaging system with near real-time reconstruction capability for point-of-care applications J Jiang, K Li, B Qi, S Komarov, JA O’Sullivan, Y Zeng, R Wahidi, Q Zhu, ... 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2017 | 1 | 2017 |
Initial results from a prototype flat-panel virtual-pinhole PET insert system for improving lesion detectability J Jiang, K Li, Q Wang, D Tomov, S Komarov, J O'Sullivan, YC Tai Journal of Nuclear Medicine 58 (supplement 1), 429-429, 2017 | 1 | 2017 |
Development of energy recognizable type gamma camera mounted on an unmanned helicopter H Sato, S Ito, Y Usuki, Y Shikaze, T Torii, Y Nishizawa, Y Sanada, ... Hihakai Kensa 65 (5), 192-201, 2016 | 1 | 2016 |
Performance evaluation of a GAGG-SiPM based compton camera for gamma-ray astronomy J Hua, H Wang, C Li, Y Dong, Z Yuan, H Yang, Y Liu, J Jiang Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2024 | | 2024 |
Cycle-Constrained Adversarial Denoising Convolutional Network for PET Image Denoising: Multi-Dimensional Validation on Large Datasets with Reader Study and Real Low-Dose Data Y Hou, F Zhan, X Cheng, C Li, Z Yuan, R Liao, H Wang, J Hua, J Wu, ... arXiv preprint arXiv:2410.23628, 2024 | | 2024 |
Deep learning-based PET image correction and optimization from CT-less PET data H Qiao, F Zhan, J Hua, Z Yuan, C Li, Y Hou, H Wang, J Jiang 2024 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC …, 2024 | | 2024 |
Feasibility study of a LYSO-SiPM based prototype for hybrid Compton and PET imaging H Wang, Y Hou, J Hua, Z Yuan, C Li, R Liao, J Jiang 2024 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC …, 2024 | | 2024 |
Initial Result of Low-dose PET Image Recovery using Cycle Denoising Adversarial Convolutional Network Y Hou, F Zhan, H Wang, J Hua, Z Yuan, C Li, R Liao, J Jiang 2024 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC …, 2024 | | 2024 |