A novel procedure for determining the optimal MLC configuration parameters in treatment planning systems based on measurements with a Farmer chamber J Saez, V Hernandez, J Goossens, G De Kerf, D Verellen Physics in Medicine & Biology 65 (15), 155006, 2020 | 22 | 2020 |
Two-dimensional real-time quality assurance dosimetry system using μ-Al2O3: C, Mg radioluminescence films LF Nascimento, D Verellen, J Goossens, L Struelens, F Vanhavere, ... Physics and imaging in radiation oncology 16, 26-32, 2020 | 18 | 2020 |
Real-time two dimensional dosimetry using Al2O3: C and Al2O3: C, Mg films LF Nascimento, J Goossens, P Leblans, P Sterckx, F Vanhavere, ... Sensors and Actuators A: Physical 318, 112491, 2021 | 10 | 2021 |
Experimental determination of the energy response of alanine pellets in the high dose rate 192Ir spectrum B Schaeken, R Cuypers, J Goossens, D Van den Weyngaert, D Verellen Physics in Medicine & Biology 56 (20), 6625, 2011 | 8 | 2011 |
Characterisation and Quenching Correction for an Al2O3:C Optical Fibre Real Time System in Therapeutic Proton, Helium, and Carbon-Charged Beams L de Freitas Nascimento, P Leblans, B van der Heyden, M Akselrod, ... Sensors 22 (23), 9178, 2022 | 7 | 2022 |
Characterization and quenching correction for a 2D real time radioluminescent system in therapeutic proton and carbon charged beams LF Nascimento, P Leblans, B van der Heyden, M Akselrod, J Goossens, ... Sensors and Actuators A: Physical 345, 113781, 2022 | 6 | 2022 |
Universal evaluation of MLC models in treatment planning systems based on a common set of dynamic tests J Saez, R Bar-Deroma, E Bogaert, R Cayez, T Chow, CH Clark, ... Radiotherapy and Oncology 186, 109775, 2023 | 5 | 2023 |
Investigation of 2D radiophotoluminescence films in radiotherapy: Multileaf collimator Quality Assurance and small field dosimetry L de Freitas Nascimento, F Castellano, J Goossens, A van Dijk, P Leblans, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2022 | 5 | 2022 |
Two-dimensional real-time dosimetry system using micro-and nano-(C44H38P2) MnCl4 radioluminescence coatings L de Freitas Nascimento, M De Saint-Hubert, W Crijns, M Caprioli, ... Radiation Measurements 176, 107212, 2024 | 2 | 2024 |
Two-dimensional real-time dosimetry system using micro-and nano-(C₄₄H₃₈P₂) MnCl₄ radioluminescence coatings LF de Nascimento, D Saint-Hubert, W Crijns, M Caprioli, L Delombaerde, ... Radiation measurements.-Oxford, 1994, currens 176, 1-11, 2024 | | 2024 |
OC-0120 MLC modelling assessment with a set of standardized tests: Results from a multicentric study J Saez, R Bar-Deroma, E Bogaert, R Cayez, T Chow, M Esposito, ... Radiotherapy and Oncology 170, S94-S96, 2022 | | 2022 |
Characterisation and quenching correction for an Al₂O₃: C optical fibre real time system in therapeutic proton, helium, and carbon-charged beams LF de Nascimento, P Leblans, B van der Heyden, M Akselrod, ... Sensors.-- 22 (23), 1-25, 2022 | | 2022 |
Promises of film dosimetry based on radiophotoluminescence imaging in radiotherapy including charged particle beams M De Saint-Hubert, F Castellano, W Crijns, S Kodaira, J Swakoń, ... Physica Medica 92, S11-S12, 2021 | | 2021 |
OC-0635: ImageDosis: 2D real-time dosimetry system LDF Nascimento, D Verellen, J Goossens, F Vanhavere, M Akselrod Radiotherapy and Oncology 152, S354, 2020 | | 2020 |
LATE TOXICITY AFTER INTENSITY-MODULATED RADIOTHERAPY (IMRT) FOR PROSTATE CANCER F Vandaele, D Van Gestel, J Goossens, A Coelmont, C Goor, P Meijnders, ... RADIOTHERAPY AND ONCOLOGY 96, S408-S409, 2010 | | 2010 |
DEVIATION CORRECTION METHOD FOR POSITIONING PATIENTS WITH PROSTATE ADENOCARCINOMA AND A HIP IMPLANT, BY MEANS OF IMPLANT MARKERS K De Vos, R Swiggers, J Goossens, I Jacobs, C Goor, ... RADIOTHERAPY AND ONCOLOGY 88, S319-S319, 2008 | | 2008 |
ACCURACY OF DOSE CALCULATIONS FOR SINUS ETHMOIDALIS PATIENTS TREATED WITH HELICAL TOMOTHERAPY. B De Ost, B Schaeken, D Van Gestel, J Goossens, D Van den Weyngaert RADIOTHERAPY AND ONCOLOGY 88, S380-S381, 2008 | | 2008 |