Polyethylene/boron nitride composites for space radiation shielding C Harrison, S Weaver, C Bertelsen, E Burgett, N Hertel, E Grulke Journal of applied polymer science 109 (4), 2529-2538, 2008 | 260 | 2008 |
Conversion coefficients for radiological protection quantities for external radiation exposures N Petoussi-Henss, WE Bolch, KF Eckerman, A Endo, N Hertel, J Hunt, ... Annals of the ICRP 40 (2-5), 1-257, 2010 | 213 | 2010 |
Calculation of effective dose from measurements of secondary neutron spectra and scattered photon dose from dynamic MLC IMRT for, and beam energies RM Howell, NE Hertel, Z Wang, J Hutchinson, GD Fullerton Medical physics 33 (2), 360-368, 2006 | 190 | 2006 |
Secondary neutron spectra from modern Varian, Siemens, and Elekta linacs with multileaf collimators RM Howell, SF Kry, E Burgett, NE Hertel, DS Followill Medical physics 36 (9Part1), 4027-4038, 2009 | 149 | 2009 |
Investigation of secondary neutron dose for dynamic MLC IMRT delivery RM Howell, MS Ferenci, NE Hertel, GD Fullerton Medical physics 32 (3), 786-793, 2005 | 128 | 2005 |
The response of Bonner spheres to neutrons from thermal energies to 17.3 MeV NE Hertel, JW Davidson Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 1985 | 108 | 1985 |
A time projection chamber for high accuracy and precision fission cross-section measurements M Heffner, DM Asner, RG Baker, J Baker, S Barrett, C Brune, J Bundgaard, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2014 | 81 | 2014 |
Polyethylene/boron composites for radiation shielding applications C Harrison, E Burgett, N Hertel, E Grulke AIP Conference Proceedings 969 (1), 484-491, 2008 | 72 | 2008 |
Gadolinium neutron capture therapy GA Miller Jr, NE Hertel, BW Wehring, JL Horton Nuclear technology 103 (3), 320-331, 1993 | 60 | 1993 |
Response Matrix for a Multisphere Spectrometer using a 6LiF Thermoluminescence Dosemeter HR Vega Carrillo, BW Wehring, KG Veinot, NE Hertel Radiation Protection Dosimetry 81 (2), 133-139, 1999 | 59 | 1999 |
Measurements of secondary neutron dose from 15 MV and 18 MV IMRT RM Howell, MS Ferenci, NE Hertel, GD Fullerton, T Fox, LW Davis Radiation protection dosimetry 115 (1-4), 508-512, 2005 | 57 | 2005 |
BUMS—Bonner sphere Unfolding Made Simple: an HTML based multisphere neutron spectrometer unfolding package J Sweezy, N Hertel, K Veinot Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2002 | 47 | 2002 |
Measurement of the normalized cross section ratio from threshold to 30 MeV with the NIFFTE fission Time Projection Chamber RJ Casperson, DM Asner, J Baker, RG Baker, JS Barrett, NS Bowden, ... Physical Review C 97 (3), 034618, 2018 | 39 | 2018 |
Effective quality factors for neutrons based on the revised ICRP/ICRU recommendations KG Veinot, NE Hertel Radiation protection dosimetry 115 (1-4), 536-541, 2005 | 39 | 2005 |
Effective dose equivalents and effective doses for neutrons from 30 to 180 MeV BK Nabelssi, NE Hertel Radiation protection dosimetry 48 (3), 227-243, 1993 | 39 | 1993 |
Calibration of a Bonner sphere extension (BSE) for high-energy neutron spectrometry RM Howell, EA Burgett, B Wiegel, NE Hertel Radiation measurements 45 (10), 1233-1237, 2010 | 37 | 2010 |
Neutron measurements in the vicinity of a self-shielded PET cyclotron NE Hertel, MP Shannon, ZL Wang, MP Valenzano, W Mengesha, ... Radiation protection dosimetry 108 (3), 255-261, 2004 | 35 | 2004 |
The ICRU proposal for new operational quantities for external radiation T Otto, NE Hertel, DT Bartlett, R Behrens, JM Bordy, G Dietze, A Endo, ... Radiation protection dosimetry 180 (1-4), 10-16, 2018 | 33 | 2018 |
Performance of multisphere spectrometry systems JE Sweezy, NE Hertel, KG Veinot, RA Karam Radiation Protection Dosimetry 78 (4), 263-272, 1998 | 32 | 1998 |
Personal dose equivalent conversion coefficients for photons to 1 GeV KG Veinot, NE Hertel Radiation protection dosimetry 145 (1), 28-35, 2011 | 30 | 2011 |