Cerebrovascular reactivity to carbon dioxide tension in newborns: data from combined time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy S Passera, A De Carli, M Fumagalli, D Contini, N Pesenti, C Amendola, ... Neurophotonics 10 (4), 045003-045003, 2023 | | 2023 |
Somatosensory prediction in the premature neonate brain V Dumont, M Giovannella, D Zuba, R Clouard, T Durduran, B Guillois, ... Developmental Cognitive Neuroscience 57, 101148, 2022 | 8 | 2022 |
Microvascular blood flow changes of the abductor pollicis brevis muscle during sustained static exercise M Giovannella, E Urtane, M Zanoletti, U Karadeniz, U Rubins, UM Weigel, ... Biomedical Optics Express 12 (7), 4235-4248, 2021 | 2 | 2021 |
Recipes for diffuse correlation spectroscopy instrument design using commonly utilized hardware based on targets for signal-to-noise ratio and precision L Cortese, G Lo Presti, M Pagliazzi, D Contini, A Dalla Mora, H Dehghani, ... Biomedical Optics Express 12 (6), 3265-3281, 2021 | 19 | 2021 |
Optimization of diffuse correlation spectroscopy instrumental and experimental parameters based on precision targets L Cortese, GL Presti, M Pagliazzi, JB Fischer, M Giovannella, M Zanoletti, ... Optical Tomography and Spectroscopy of Tissue XIV 11639, 116390X, 2021 | | 2021 |
Validation of diffuse correlation spectroscopy against 15O-water PET for regional cerebral blood flow measurement in neonatal piglets M Giovannella, B Andresen, JB Andersen, S El-Mahdaoui, D Contini, ... Journal of Cerebral Blood Flow & Metabolism 40 (10), 2055-2065, 2020 | 42 | 2020 |
Effects of Different Hardware and Measurement Parameters on Diffuse Correlation Spectroscopy L Cortese, GL Presti, M Giovannella, JB Fischer, M Pagliazzi, M Zanoletti, ... OSA Technical Digest, 1-2, 2020 | | 2020 |
Cerebral oxygenation and blood flow in term infants during postnatal transition: BabyLux project A De Carli, B Andresen, M Giovannella, T Durduran, D Contini, L Spinelli, ... Archives of Disease in Childhood-Fetal and Neonatal Edition 104 (6), F648-F653, 2019 | 14 | 2019 |
Cerebral oxygenation and blood flow in normal term infants at rest measured by a hybrid near-infrared device (BabyLux) B Andresen, A De Carli, M Fumagalli, M Giovannella, T Durduran, ... Pediatric Research 86 (4), 515-521, 2019 | 22 | 2019 |
Validation of diffuse correlation spectroscopy (babylux device) against O-15-water PET for regional cerebral blood flow measurement in neonatal piglets M Giovannella, B Andresen, JB Andersen, S El-Mahdaoui, D Contini, ... JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM 39, 185-186, 2019 | | 2019 |
Hybrid diffuse optical neuromonitoring of cerebral haemodynamics: from the smallest premature born infants to adults M Giovannella Universitat Politècnica de Catalunya, 2019 | | 2019 |
Accuracy and precision of tissue optical properties and hemodynamic parameters estimated by the BabyLux device: a hybrid time-resolved near-infrared and diffuse correlation … M Giovannella, L Spinelli, M Pagliazzi, D Contini, G Greisen, UM Weigel, ... Biomedical optics express 10 (5), 2556-2579, 2019 | 14 | 2019 |
BabyLux device: a diffuse optical system integrating diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy for the neuromonitoring of the premature … M Giovannella, D Contini, M Pagliazzi, A Pifferi, L Spinelli, R Erdmann, ... Neurophotonics 6 (2), 025007-025007, 2019 | 55 | 2019 |
The BabyLux device: Baseline hemodynamic and optical properties of the newborn brain and the reproducibility of the measurements M Giovannella, B Andresen, A De Carli, M Pagliazzi, M Fumagalli, ... Optical Tomography and Spectroscopy, OW4C. 2, 2018 | 4 | 2018 |
Cerebral vasoreactivity in response to a head-of-bed position change is altered in patients with moderate and severe obstructive sleep apnea C Gregori-Pla, G Cotta, I Blanco, P Zirak, M Giovannella, A Mola, ... PLoS One 13 (3), e0194204, 2018 | 12 | 2018 |
Concurrent measurement of cerebral hemodynamics and electroencephalography during transcranial direct current stimulation M Giovannella, D Ibañez, C Gregori-Pla, M Kacprzak, G Mitjà, G Ruffini, ... Neurophotonics 5 (1), 015001-015001, 2018 | 28 | 2018 |
Functional diffuse correlation spectroscopy to investigate the perception of missing stimuli in a regular tactile sequence by preterm neonates V Dumont, D Zuba, S Lebargy, M Giovannella, T Durduran, U Weigel, ... JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM 37, 365-366, 2017 | 1 | 2017 |
Baseline haemodynamic and optical properties of the newborn brain and the reproducibility of the measurements: a preliminary report from the BabyLux project M Giovannella, B Andresen, A Carli, V Chamizo, M Pagliazzi, ... | | 2017 |
Cerebral Blood Flow Response to Orthostatic Challenges in Healthy and Diseased Populations D Busch, C Gregori-Pla, I Blanco, M Giovannella, C Favilla, J Lynch, ... ANNALS OF NEUROLOGY 80, S347-S347, 2016 | | 2016 |
Measurement of haemodynamics of exercising and non-exercising vastus lateralis muscle with hybrid diffuse optics M Giovannella, E Urtane, V Chamizo, L Spinelli, R Re, UM Weigel, ... Optical Tomography and Spectroscopy, OTh2C. 4, 2016 | | 2016 |