1st EFORT European Consensus “Medical & Scientific Research Requirements for the Clinical Introduction of Artificial Joint Arthroplasty Devices”: Background, Delphi Methodology …
TM Grupp, S Rusch, P Massin, A Blom, E Garcia-Rey, L Cristofolini, ...
EFORT Open Reviews 8 (7), 499-508, 2023
22023
1st EFORT European Consensus: Medical & Scientific Research Requirements for the Clinical Introduction of Artificial Joint Arthroplasty Devices
M Grupp Thomas, S Overgaard, KP Günther, A Blom, L Cristofolini, ...
EFORT, 2023
2023
A biomechanical analysis of a PEEK-Optima® femoral component on implant fixation, Construct integrity and bone remodeling opportunities in total knee arthroplasty
L De Ruiter, D Janssen, A Briscoe, NJJ Verdonschot
Poster presented at the Annual congress of the Orthopaedic Research Society, 2014
12014
A biomechanical comparison of four hip arthroplasty designs in a canine model
NR Ordway, KJ Ash, MA Miller, KA Mann, K Hayashi
Veterinary and Comparative Orthopaedics and Traumatology 32 (05), 369-375, 2019
112019
A combined experimental and finite element approach to analyse the fretting mechanism of the head–stem taper junction in total hip replacement
T Bitter, I Khan, T Marriott, E Lovelady, N Verdonschot, D Janssen
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2017
252017
A comparison between dynamic implicit and explicit finite element simulations of the native knee joint
HN Beidokhti, D Janssen, M Khoshgoftar, A Sprengers, ES Perdahcioglu, ...
Medical engineering & physics 38 (10), 1123-1130, 2016
562016
A FE study on the effect of interference fit and coefficient of friction on the micromotions and interface gaps of a cementless PEEK femoral component
CE Post, T Bitter, A Briscoe, N Verdonschot, D Janssen
Journal of Biomechanics 137, 111057, 2022
132022
A FINITE ELEMENT STUDY ON OVERLOADING OF THE RECONSTRUCTED TIBIA DURING ACTIVITIES OF DAILY LIVING
P Srinivasan, M Miller, N Verdonschot, K Mann, D Janssen
Orthopaedic Proceedings 100 (SUPP_5), 78-78, 2018
2018
A modelling approach demonstrating micromechanical changes in the tibial cemented interface due to in vivo service
P Srinivasan, MA Miller, N Verdonschot, KA Mann, D Janssen
Journal of biomechanics 56, 19-25, 2017
52017
A new approach to quantify trabecular resorption adjacent to cemented knee arthroplasty
KA Mann, MA Miller, CL Pray, N Verdonschot, D Janssen
Journal of biomechanics 45 (4), 711-715, 2012
292012
A noninvasive MRI based approach to estimate the mechanical properties of human knee ligaments
H Naghibi, V Mazzoli, K Gijsbertse, G Hannink, A Sprengers, D Janssen, ...
Journal of the mechanical behavior of biomedical materials 93, 43-51, 2019
152019
A novel approach for optimal graft positioning and tensioning in anterior cruciate ligament reconstructive surgery based on the finite element modeling technique
H Naghibi, D Janssen, T Van Tienen, S Van de Groes, ...
The knee 27 (2), 384-396, 2020
242020
A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait
L De Ruiter, D Janssen, A Briscoe, N Verdonschot
Journal of experimental orthopaedics 4, 1-8, 2017
442017
A693. FINITE ELEMENT ANALYSIS OF CEMENT-BONE INTERFACE MICROMECHANICS: THE EFFECT OF CEMENT PENETRATION DEPTH
D Janssen, D Waanders, KA Mann, N Verdonschot
Orthopaedic Proceedings 93 (SUPP_IV), 425-426, 2011
2011
Acetabular load-transfer and mechanical stability: a finite element analysis comparing different cementless sockets
DFM Pakvis, D Janssen, BW Schreurs, N Verdonschot
Journal of Mechanics in Medicine and Biology 14 (05), 1450063, 2014
32014
Acetabular stress shielding. A finite element analysis of a cemented rigid and a cementless elastic socket.
DFM Pakvis, D Janssen, NJJ Verdonschot
Annual Congress of the Dutch Orthopaedic Foundation (NOV), 2010
2010
ACETABULAR STRESS SHIELDING. A FINITE ELEMENT ANALYSIS OF A CEMENTED, A CEMENTLESS RIGID AND A CEMENTLESS ELASTIC SOCKET: O224
D Pakvis, D Janssen, N Verdonschot
Hip International 20 (3), 2010
2010
ADAPTIVE COMPUTATIONAL MODELLING OF FRETTING AT THE TAPER INTERFACE
T Bitter, D Janssen, BW Schreurs, T Marriott, E Lovelady, I Khan, ...
Orthopaedic Proceedings 99 (SUPP_3), 46-46, 2017
2017
Alignment deviations between the longitudinal axis of the CT scanner and femur lead to substantial changes in TT-TG distance
H Dunning, H Chen, SAW van de Groes, N Verdonschot, D Janssen
THE KNEE IN MOTION, 39, 0
AN EXPERIMENTAL PRE-CLINICAL ASSESSMENT OF THE PRIMARY STABILITY OF A NOVEL CEMENTLESS FEMORAL KNEE COMPONENT RELATIVE TO A CLINICALLY SUCCESSFUL DESIGN
S Berahmani, D Janssen, D Wolfson, M Hendriks, A Wright, MDW Malefijt, ...
Orthopaedic Proceedings 98 (SUPP_7), 37-37, 2016
2016