关注
Martín Resano
标题
引用次数
引用次数
年份
Inductively coupled plasma–Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra) trace elements–A tutorial review
L Balcaen, E Bolea-Fernandez, M Resano, F Vanhaecke
Analytica chimica acta 894, 7-19, 2015
3752015
Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry—a critical review with focus on solid sampling and …
M Resano, F Vanhaecke, MTC de Loos-Vollebregt
Journal of Analytical Atomic Spectrometry 23 (11), 1450-1475, 2008
1952008
Direct solid sampling with electrothermal vaporization/atomization: what for and how?
MA Belarra, M Resano, F Vanhaecke, L Moens
TrAC Trends in Analytical Chemistry 21 (12), 828-839, 2002
1892002
Overcoming spectral overlap via inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS). A tutorial review
E Bolea-Fernandez, L Balcaen, M Resano, F Vanhaecke
Journal of Analytical Atomic Spectrometry 32 (9), 1660-1679, 2017
1742017
Laser ablation‐inductively coupled plasma mass spectrometry in archaeometric research
M Resano, E García‐Ruiz, F Vanhaecke
Mass Spectrometry Reviews 29 (1), 55-78, 2010
1292010
High-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of solid samples and complex materials: a tutorial review
M Resano, M Aramendía, MA Belarra
Journal of Analytical Atomic Spectrometry 29, 2229-2250, 2014
1282014
Electrothermal vaporization–inductively coupled plasma-mass spectrometry: A versatile tool for tackling challenging samples: A critical review
M Aramendía, M Resano, F Vanhaecke
Analytica chimica acta 648 (1), 23-44, 2009
1212009
Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS
L Balcaen, E Bolea-Fernandez, M Resano, F Vanhaecke
Analytica Chimica Acta 809, 1-8, 2014
1202014
Accurate determination of S in organic matrices using isotope dilution ICP-MS/MS
L Balcaen, G Woods, M Resano, F Vanhaecke
Journal of Analytical Atomic Spectrometry 28 (1), 33-39, 2013
1182013
High-resolution continuum source atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple lines. A critical review of current possibilities
M Resano, MR Flórez, E García-Ruiz
Spectrochimica Acta Part B: Atomic Spectroscopy 88, 85-97, 2013
1102013
Direct determination of methylmercury and inorganic mercury in biological materials by solid sampling-electrothermal vaporization-inductively coupled plasma-isotope dilution …
I Gelaude, R Dams, M Resano, F Vanhaecke, L Moens
Analytical chemistry 74 (15), 3833-3842, 2002
962002
Isotopic analysis of Cu in serum samples for diagnosis of Wilson's disease: a pilot study
M Aramendía, L Rello, M Resano, F Vanhaecke
Journal of Analytical Atomic Spectrometry 28 (5), 675-681, 2013
952013
On the possibilities of high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple atomic lines
M Resano, L Rello, M Flórez, MA Belarra
Spectrochimica Acta Part B: Atomic Spectroscopy 66 (5), 321-328, 2011
922011
Progress in the determination of metalloids and non-metals by means of high-resolution continuum source atomic or molecular absorption spectrometry. A critical review
M Resano, MR Flórez, E García-Ruiz
Analytical and bioanalytical chemistry 406, 2239-2259, 2014
862014
High-resolution continuum source graphite furnace atomic absorption spectrometry: Is it as good as it sounds? A critical review
M Resano, E García-Ruiz
Analytical and bioanalytical chemistry 399, 323-330, 2011
852011
Interference-free determination of ultra-trace concentrations of arsenic and selenium using methyl fluoride as a reaction gas in ICP–MS/MS
E Bolea-Fernandez, L Balcaen, M Resano, F Vanhaecke
Analytical and bioanalytical chemistry 407 (3), 919-929, 2015
822015
Electrothermal vaporisation ICP-mass spectrometry (ETV-ICP-MS) for the determination and speciation of trace elements in solid samples–A review of real-life applications from …
F Vanhaecke, M Resano, L Moens
Analytical and bioanalytical chemistry 374, 188-195, 2002
822002
Direct determination of Hg in polymers by solid sampling-graphite furnace atomic absorption spectrometry: a comparison of the performance of line source and continuum source …
M Resano, J Briceño, MA Belarra
Spectrochimica Acta Part B: Atomic Spectroscopy 64 (6), 520-529, 2009
802009
On the effect of using collision/reaction cell (CRC) technology in single-particle ICP-mass spectrometry (SP-ICP-MS)
E Bolea-Fernandez, D Leite, A Rua-Ibarz, T Liu, G Woods, M Aramendia, ...
Analytica Chimica Acta 1077, 95-106, 2019
792019
Characterization of cobalt pigments found in traditional Valencian ceramics by means of laser ablation-inductively coupled plasma mass spectrometry and portable X-ray …
J Pérez-Arantegui, M Resano, E García-Ruiz, F Vanhaecke, C Roldán, ...
Talanta 74 (5), 1271-1280, 2008
792008
系统目前无法执行此操作,请稍后再试。
文章 1–20