Monte Carlo calculations of, the beam quality conversion factor BR Muir, DWO Rogers Medical physics 37 (11), 5939-5950, 2010 | 158 | 2010 |
Measured and Monte Carlo calculated kQ factors: Accuracy and comparison BR Muir, MR McEwen, DWO Rogers Medical physics 38 (8), 4600-4609, 2011 | 69 | 2011 |
Beam quality conversion factors for parallel‐plate ionization chambers in MV photon beams BR Muir, MR McEwen, DWO Rogers Medical Physics 39 (3), 1618-1631, 2012 | 53 | 2012 |
Determination of consensus kQ values for megavoltage photon beams for the update of IAEA TRS-398 P Andreo, DT Burns, RP Kapsch, M McEwen, S Vatnitsky, CE Andersen, ... Physics in Medicine & Biology 65 (9), 095011, 2020 | 51 | 2020 |
Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types BR Muir, DWO Rogers Medical Physics 41 (11), 111701, 2014 | 44 | 2014 |
The central electrode correction factor for high‐Z electrodes in small ionization chambers BR Muir, DWO Rogers Medical Physics 38 (2), 1081-1088, 2011 | 43 | 2011 |
Monte Carlo calculations for reference dosimetry of electron beams with the PTW Roos and NE2571 ion chambers BR Muir, DWO Rogers Medical Physics 40 (12), 121722, 2013 | 26 | 2013 |
Cherenkov emission‐based external radiotherapy dosimetry: I. Formalism and feasibility Y Zlateva, BR Muir, I El Naqa, JP Seuntjens Medical physics 46 (5), 2370-2382, 2019 | 24 | 2019 |
Cherenkov emission‐based external radiotherapy dosimetry: II. Electron beam quality specification and uncertainties Y Zlateva, BR Muir, JP Seuntjens, I El Naqa Medical physics 46 (5), 2383-2393, 2019 | 23 | 2019 |
Ion chamber absorbed dose calibration coefficients, ND,w, measured at ADCLs: Distribution analysis and stability BR Muir Medical Physics 42 (4), 1546-1554, 2015 | 20 | 2015 |
On the impact of ICRU report 90 recommendations on kQ factors for high‐energy photon beams E Mainegra‐Hing, BR Muir Medical Physics 45 (8), 3904-3908, 2018 | 15 | 2018 |
Electron beam water calorimetry measurements to obtain beam quality conversion factors BR Muir, CD Cojocaru, MR McEwen, CK Ross Medical Physics 44 (10), 5433-5444, 2017 | 15 | 2017 |
On the use of cylindrical ionization chambers for electron beam reference dosimetry BR Muir, MR McEwen Medical physics 44 (12), 6641-6646, 2017 | 14 | 2017 |
Determination of relative ion chamber calibration coefficients from depth-ionization measurements in clinical electron beams BR Muir, MR McEwen, DWO Rogers Physics in Medicine & Biology 59 (19), 5953, 2014 | 13 | 2014 |
Insight gained from responses to surveys on reference dosimetry practices B Muir, W Culberson, S Davis, GY Kim, Y Huang, SW Lee, J Lowenstein, ... Journal of applied clinical medical physics 18 (3), 182-190, 2017 | 12 | 2017 |
AAPM WGTG51 Report 374: guidance for TG‐51 reference dosimetry B Muir, W Culberson, S Davis, GGY Kim, SW Lee, J Lowenstein, ... Medical physics 49 (11), 6739-6764, 2022 | 10 | 2022 |
A modified formalism for electron beam reference dosimetry to improve the accuracy of linac output calibration BR Muir Medical Physics 47 (5), 2267-2276, 2020 | 9 | 2020 |
60Co phase-space files generated using BEAMnrc B Muir, G Xiong, TP Selvam, DWO Rogers Technical ReportCLRP, 09-01, 2009 | 8 | 2009 |
Assessing the accuracy of electronic portal imaging device (EPID)‐based dosimetry: I. Quantities influencing long‐term stability J Renaud, B Muir Medical Physics 49 (2), 1231-1237, 2022 | 6 | 2022 |
High spatial resolution dosimetry with uncertainty analysis using Raman micro‐spectroscopy readout of radiochromic films C Mcnairn, I Mansour, B Muir, RM Thomson, S Murugkar Medical Physics 48 (8), 4610-4620, 2021 | 6 | 2021 |