Daylight coefficients PR Tregenza, IM Waters Lighting Research & Technology 15 (2), 65-71, 1983 | 435 | 1983 |
Subdivision of the sky hemisphere for luminance measurements PR Tregenza Lighting Research & Technology 19 (1), 13-14, 1987 | 326 | 1987 |
Quality of life and building design in residential and nursing homes for older people C Parker, S Barnes, K McKee, K Morgan, J Torrington, P Tregenza Ageing & Society 24 (6), 941-962, 2004 | 296 | 2004 |
Daylighting: architecture and lighting design P Tregenza, M Wilson Routledge, 2013 | 282 | 2013 |
View and discomfort glare from windows N Tuaycharoen, PR Tregenza Lighting Research & Technology 39 (2), 185-200, 2007 | 257 | 2007 |
The design of lighting P Tregenza, D Loe Routledge, 2013 | 228 | 2013 |
The design of interior circulation: People and buildings P Tregenza (No Title), 1976 | 151 | 1976 |
Discomfort glare from interesting images N Tuaycharoen, PR Tregenza Lighting Research & Technology 37 (4), 329-338, 2005 | 144 | 2005 |
Analysing sky luminance scans to obtain frequency distributions of CIE Standard General Skies PR Tregenza Lighting Research & Technology 36 (4), 271-279, 2004 | 135 | 2004 |
Standard skies for maritime climates PR Tregenza International Journal of Lighting Research and Technology 31 (3), 97-106, 1999 | 126 | 1999 |
Lighting for people with dementia JM Torrington, PR Tregenza Lighting Research & Technology 39 (1), 81-97, 2007 | 122 | 2007 |
Mean daylight illuminance in rooms facing sunlit streets PR Tregenza Building and environment 30 (1), 83-89, 1995 | 120 | 1995 |
The daylight factor and actual illuminance ratios PR Tregenza Lighting Research & Technology 12 (2), 64-68, 1980 | 112 | 1980 |
The Monte Carlo method in lighting calculations PR Tregenza Lighting Research & Technology 15 (4), 163-170, 1983 | 93 | 1983 |
Modification of the split-flux formulae for mean daylight factor and internal reflected component with large external obstructions PR Tregenza Lighting Research & Technology 21 (3), 125-128, 1989 | 85 | 1989 |
Daylighting buildings: Standards and the needs of the designer P Tregenza, J Mardaljevic Lighting Research & Technology 50 (1), 63-79, 2018 | 78 | 2018 |
Temporal effects on glare response from daylight MG Kent, S Altomonte, R Wilson, PR Tregenza Building and Environment 113, 49-64, 2017 | 69 | 2017 |
Daylighting algorithms P Tregenza | 64 | 1993 |
Guide to recommended practice of daylight measurement International Commission on Illumination Commission Internationale De L'Eclairage, 1994 | 61 | 1994 |
Visual task difficulty and temporal influences in glare response S Altomonte, MG Kent, PR Tregenza, R Wilson Building and Environment 95, 209-226, 2016 | 53 | 2016 |