Characteristics of cooking-generated PM10 and PM2. 5 in residential buildings with different cooking and ventilation types K Kang, H Kim, DD Kim, YG Lee, T Kim Science of the total environment 668, 56-66, 2019 | 114 | 2019 |
Measurement of particulate matter (PM2. 5) and health risk assessment of cooking-generated particles in the kitchen and living rooms of apartment houses H Kim, K Kang, T Kim Sustainability 10 (3), 843, 2018 | 67 | 2018 |
Review of vision-based occupant information sensing systems for occupant-centric control H Choi, CY Um, K Kang, H Kim, T Kim Building and Environment 203, 108064, 2021 | 48 | 2021 |
Cooling energy performance and thermal characteristics of a naturally ventilated slim double-skin window H Choi, Y An, K Kang, S Yoon, T Kim Applied Thermal Engineering 160, 114113, 2019 | 39 | 2019 |
Application of vision-based occupancy counting method using deep learning and performance analysis H Choi, CY Um, K Kang, H Kim, T Kim Energy and Buildings 252, 111389, 2021 | 35 | 2021 |
Effect of indoor and outdoor sources on indoor particle concentrations in South Korean residential buildings K Kang, T Kim, H Kim Journal of Hazardous Materials 416, 125852, 2021 | 27 | 2021 |
Occupant behavior and indoor particulate concentrations in daycare centers CY Um, N Zhang, K Kang, HS Na, H Choi, T Kim Science of the Total Environment 824, 153206, 2022 | 21 | 2022 |
Filtration efficiency and ventilation performance of window screen filters K Kang, T Kim, CW Shin, K Kim, J Kim, YG Lee Building and Environment 178, 106878, 2020 | 20 | 2020 |
Deep-vision-based metabolic rate and clothing insulation estimation for occupant-centric control H Choi, B Jeong, J Lee, H Na, K Kang, T Kim Building and Environment 221, 109345, 2022 | 16 | 2022 |
Deep vision-based occupancy counting: Experimental performance evaluation and implementation of ventilation control H Choi, J Lee, Y Yi, H Na, K Kang, T Kim Building and Environment 223, 109496, 2022 | 12 | 2022 |
Effect of occupant activity on indoor particle concentrations in Korean residential buildings H Kim, K Kang, T Kim Sustainability 12 (21), 9201, 2020 | 12 | 2020 |
A survey on Improvements of Range Hood in Apartment K Kang, T Kim, Y Lee KIEAE journal 17 (5), 43-50, 2017 | 9 | 2017 |
CFD simulation analysis on make-up air supply by distance from cookstove for cooking-generated particle H Kim, K Kang, T Kim International journal of environmental research and public health 17 (21), 7799, 2020 | 8 | 2020 |
An investigation of concentration and health impacts of aldehydes associated with cooking in 29 residential buildings K Kang, T Kim, DD Kim Indoor Air 2023 (1), 2463386, 2023 | 7 | 2023 |
Empirical analysis of the effects of window remodeling using the slim double-skin window on the thermal performance of old buildings Y An, H Choi, E Kim, K Kang, S Kim, T Kim Energy and Buildings 277, 112581, 2022 | 7 | 2022 |
Black carbon and PM2. 5 impact analysis in an urban school D Park, T Kim, K Kang E3S Web of Conferences 396, 01056, 2023 | 5 | 2023 |
Assessment of PM2. 5 penetration based on airflow paths in Korean classrooms S Kim, K Kang, D Park, T Kim Building and Environment 248, 111103, 2024 | 3 | 2024 |
Range hood and make-up air supply system to prevent dispersion of cooking-generated particulate matter H Kim, K Kang, T Kim Aerosol and Air Quality Research 21 (5), 200421, 2021 | 3 | 2021 |
Analysis of heat transfer in a slim double skin façade using CFD simulation H Choi, K Kang, Y An, E Kim, Y Lee, T Kim Proceedings of the 16th International IBPSA Conference (Building Simulation …, 2019 | 3 | 2019 |
BEAT 프로그램을 이용한 건물에너지 retrofit 요소들 간의 에너지 절감 관계분석 김현수, 최기원, 장지훈, 강경모, 이승복 대한건축학회 논문집-구조계 33 (2), 97-105, 2017 | 3 | 2017 |