Comparisons of computed mobile phone induced SAR in the SAM phantom to that in anatomically correct models of the human head BB Beard, W Kainz, T Onishi, T Iyama, S Watanabe, O Fujiwara, J Wang, ... IEEE transactions on electromagnetic compatibility 48 (2), 397-407, 2006 | 247 | 2006 |
Dosimetric comparison of the specific anthropomorphic mannequin (SAM) to 14 anatomical head models using a novel definition for the mobile phone positioning W Kainz, A Christ, T Kellom, S Seidman, N Nikoloski, B Beard, N Kuster Physics in Medicine & Biology 50 (14), 3423, 2005 | 93 | 2005 |
On the mechanisms of interference between mobile phones and pacemakers: parasitic demodulation of GSM signal by the sensing amplifier V Barbaro, P Bartolini, G Calcagnini, F Censi, B Beard, P Ruggera, ... Physics in Medicine & Biology 48 (11), 1661, 2003 | 46 | 2003 |
Review and standardization of cell phone exposure calculations using the SAM phantom and anatomically correct head models BB Beard, W Kainz BioMedical Engineering OnLine 3, 1-10, 2004 | 43 | 2004 |
Static magnetic field measurements of smart phones and watches and applicability to triggering magnet modes in implantable pacemakers and implantable cardioverter-defibrillators SJ Seidman, J Guag, B Beard, Z Arp Heart Rhythm 18 (10), 1741-1744, 2021 | 24 | 2021 |
Precision test apparatus for evaluating the heating pattern of radiofrequency ablation devices I Chang, B Beard Medical engineering & physics 24 (9), 633-640, 2002 | 17 | 2002 |
International intercomparison of specific absorption rates in a flat absorbing phantom in the near-field of dipole antennas CC Davis, BB Beard, A Tillman, J Rzasa, E Merideth, Q Balzano IEEE transactions on electromagnetic compatibility 48 (3), 579-588, 2006 | 13 | 2006 |
The specific anthropomorphic mannequin (SAM) compared to 14 anatomical head models using a novel definition for the mobile phone positioning W Kainz, A Christ, T Kellom, S Seidman, N Nikoloski, B Beard, N Kuster Phys. Med. Biol, 2005 | 8 | 2005 |
Precise dielectric property measurements and E-field probe calibration for specific absorption rate measurements using a rectangular waveguide BM Hakim, BB Beard, CC Davis Measurement Science and Technology 20 (4), 045702, 2009 | 6 | 2009 |
Radio frequency immunity testing of hearing aids SD Julstrom, LK Kozma-Spytek, BB Beard IEEE Electromagnetic Compatibility Magazine 2 (2), 69-87, 2013 | 5 | 2013 |
RF Interference in Hearing Aids from Cellphones Part 1: Near-field cellphone emissions measurements and the effects of hands BB Beard, SD Julstrom, LK Kozma-Spytek IEEE electromagnetic compatibility magazine 4 (3), 59-66, 2015 | 4 | 2015 |
A Multi-Frequency 3D Printed Hand Phantom for Electromagnetic Measurements BB Beard, MI Iacono, JW Guag, Y Liu IEEE electromagnetic compatibility magazine 11 (3), 49-54, 2022 | 1 | 2022 |
An alternative method for determination of low-frequency specific absorption rate patterns in homogeneous phantoms BB Beard, IA Chang Physics in Medicine & Biology 48 (13), 2013, 2003 | 1 | 2003 |
High spatial resolution measurements of specific absorption rate around ICD leads BB Beard, MS Mirotznik, IA Chang Medical engineering & physics 22 (8), 587-592, 2000 | 1 | 2000 |
Comparison of gating methods for the real-time analysis of left ventricular function in nonimaging blood pool studies BB Beard, JR Stewart, RG Shiavi, CH Lorenz Journal of Nuclear Cardiology 2 (5), 405-412, 1995 | 1 | 1995 |
Real time measurement of left ventricular pressure-volume relationships using nonimaging radionuclide techniques BB Beard Vanderbilt University, 1993 | 1 | 1993 |
RF Interference in Hearing Aids from Cellphones Part 2: Comparing in-use RF coupling to predictions SD Julstrom, LK Kozma-Spytek, BB Beard IEEE electromagnetic compatibility magazine 4 (4), 66-77, 2015 | | 2015 |
A system for postoperative visualization and analysis of left ventricular pressure–volume loops BB Beard, JR Stewart, TA Fischell Computers in biology and medicine 28 (1), 1-12, 1998 | | 1998 |
Real-time measurement of postoperative left ventricular function using nonimaging radionuclide techniques BB Beard Vanderbilt University, 1995 | | 1995 |