关注
Emil Ljungberg
Emil Ljungberg
Medical Radiation Physics, Lund University
在 med.lu.se 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Spinal cord grey matter segmentation challenge
F Prados, J Ashburner, C Blaiotta, T Brosch, J Carballido-Gamio, ...
Neuroimage 152, 312-329, 2017
1472017
Quantitative neuroimaging measures of myelin in the healthy brain and in multiple sclerosis
J O'Muircheartaigh, I Vavasour, E Ljungberg, DKB Li, A Rauscher, ...
Human Brain Mapping 40 (7), 2104-2116, 2019
572019
Assessing structure and function of myelin in cervical spondylotic myelopathy: Evidence of demyelination
H Liu, EL MacMillian, CR Jutzeler, E Ljungberg, AL MacKay, SH Kolind, ...
Neurology 89 (6), 602-610, 2017
532017
Rapid myelin water imaging in human cervical spinal cord
E Ljungberg, I Vavasour, R Tam, Y Yoo, A Rauscher, DKB Li, ...
Magnetic resonance in medicine 78 (4), 1482-1487, 2017
412017
Myelin water atlas: a template for myelin distribution in the brain
H Liu, C Rubino, AV Dvorak, M Jarrett, E Ljungberg, IM Vavasour, LE Lee, ...
Journal of Neuroimaging 29 (6), 699-706, 2019
382019
Inter-vendor reproducibility of myelin water imaging using a 3D gradient and spin echo sequence
LE Lee, E Ljungberg, D Shin, CR Figley, IM Vavasour, A Rauscher, ...
Frontiers in neuroscience 12, 854, 2018
362018
Silent zero TE MR neuroimaging: current state-of-the-art and future directions
E Ljungberg, NL Damestani, TC Wood, DJ Lythgoe, F Zelaya, ...
Progress in Nuclear Magnetic Resonance Spectroscopy 123, 73-93, 2021
342021
Rapid myelin water imaging for the assessment of cervical spinal cord myelin damage
AV Dvorak, E Ljungberg, IM Vavasour, H Liu, P Johnson, A Rauscher, ...
NeuroImage: Clinical 23, 101896, 2019
252019
Myelin Water Fraction and Intra/Extracellular Water Geometric Mean T2 Normative Atlases for the Cervical Spinal Cord from 3T MRI
H Liu, E Ljungberg, AV Dvorak, LE Lee, JT Yik, EL MacMillan, L Barlow, ...
Journal of Neuroimaging 30 (1), 50-57, 2020
202020
Simultaneous high‐resolution T2‐weighted imaging and quantitative T2 mapping at low magnetic field strengths using a multiple TE and multi‐orientation …
SCL Deoni, J O'Muircheartaigh, E Ljungberg, M Huentelman, ...
Magnetic Resonance in Medicine 88 (3), 1273-1281, 2022
182022
Silent myelin-weighted magnetic resonance imaging
TC Wood, NL Damestani, AJ Lawrence, E Ljungberg, GJ Barker, ...
Wellcome Open Research 5, 2020
122020
Silent T1 mapping using the variable flip angle method with B1 correction
E Ljungberg, T Wood, AB Solana, S Kolind, SCR Williams, F Wiesinger, ...
Magnetic Resonance in Medicine, 2020
112020
Comparison of multi echo T2 relaxation and steady state approaches for myelin imaging in the central nervous system
AV Dvorak, E Ljungberg, IM Vavasour, LE Lee, S Abel, DKB Li, ...
Scientific reports 11 (1), 1-12, 2021
102021
The evaluation of optic nerves using 7 Tesla “silent” zero echo time imaging in patients with Leber’s hereditary optic neuropathy with or without Idebenone treatment
C Grochowski, M Symms, K Jonak, P Krukow, TC Wood, E Ljungberg, ...
Journal of Clinical Medicine 9 (4), 1112, 2020
102020
Grey matter segmentation in spinal cord MRIs via 3D convolutional encoder networks with shortcut connections
A Porisky, T Brosch, E Ljungberg, LYW Tang, Y Yoo, B De Leener, ...
Deep Learning in Medical Image Analysis and Multimodal Learning for Clinical …, 2017
102017
Motion corrected silent ZTE neuroimaging
E Ljungberg, TC Wood, AB Solana, SCR Williams, GJ Barker, F Wiesinger
Magnetic Resonance in Medicine 88 (1), 195-210, 2022
92022
Multivariate template creation of a myelin water brain atlas with GRASE and mcDESPOT
A Dvorak, H Liu, E Ljungberg, I Vavasour, L Lee, A MacKay, R Tam, D Li, ...
International Society for Magnetic Resonance in Medicine, 2019
62019
Silent T1-Mapping Using the Variable Flip Angle Method with Zero Echo Time
E Ljungberg, AB Solana, T Wood, S Kolind, F Wiesinger, G Barker
Proc. Intl. Soc. Mag. Reson. Med 26, 2018
62018
Radial interstices enable speedy low-volume imaging
TC Wood, E Ljungberg, F Wiesinger
Journal of Open Source Software 6 (66), 3500, 2021
52021
Silent, 3D MR parameter mapping using magnetization prepared zero TE
F Wiesinger, MA Janich, E Ljungberg, GJ Barker, AB Solana
Proc. Intl. Soc. Mag. Reson. Med 26, 0061, 2018
52018
系统目前无法执行此操作,请稍后再试。
文章 1–20