Evaluating x-ray detectors for radiographic applications: A comparison of ZnSCdS: Ag with and screens I Kandarakis, D Cavouras, GS Panayiotakis, CD Nomicos Physics in Medicine & Biology 42 (7), 1351, 1997 | 139 | 1997 |
Modeling granular phosphor screens by Monte Carlo methods PF Liaparinos, IS Kandarakis, DA Cavouras, HB Delis, GS Panayiotakis Medical physics 33 (12), 4502-4514, 2006 | 105 | 2006 |
Validation of a GATE model for the simulation of the Siemens biograph™ 6 PET scanner P Gonias, N Bertsekas, N Karakatsanis, G Saatsakis, A Gaitanis, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2007 | 87 | 2007 |
An evaluation of the Y2O3:Eu3+ scintillator for application in medical x‐ray detectors and image receptors D Cavouras, I Kandarakis, GS Panayiotakis, EK Evangelou, CD Nomicos Medical Physics 23 (12), 1965-1975, 1996 | 79 | 1996 |
Experimental and theoretical evaluation of a high resolution CMOS based detector under X-ray imaging conditions CM Michail, VA Spyropoulou, GP Fountos, NI Kalyvas, IG Valais, ... IEEE Transactions on Nuclear Science 58 (1), 314-322, 2010 | 77 | 2010 |
Light emission efficiency and imaging performance of powder scintillator under x‐ray radiography conditions CM Michail, GP Fountos, PF Liaparinos, NE Kalyvas, I Valais, ... Medical physics 37 (7Part1), 3694-3703, 2010 | 72 | 2010 |
A study of X-ray luminescence and spectral compatibility of europium-activated yttrium-vanadate (YVO4: Eu) screens for medical imaging applications G Panayiotakis, D Cavouras, I Kandarakis, C Nomicos Applied Physics A 62, 483-486, 1996 | 66 | 1996 |
Evaluating Zn2SiO4: Mn phosphor for use in medical imaging radiation detectors I Kandarakis, D Cavouras, P Prassopoulos, E Kanellopoulos, ... Applied Physics A 67, 521-525, 1998 | 65 | 1998 |
A comparative study of the luminescence properties of LYSO: Ce, LSO: Ce, GSO: Ce and BGO single crystal scintillators for use in medical X-ray imaging I Valais, C Michail, S David, CD Nomicos, GS Panayiotakis, I Kandarakis Physica Medica 24 (2), 122-125, 2008 | 64 | 2008 |
Luminescence efficiency of Gd/sub 2/SiO/sub 5: Ce scintillator under X-ray excitation IG Valais, IS Kandarakis, DN Nikolopoulos, IA Sianoudis, N Dimitropoulos, ... IEEE transactions on nuclear science 52 (5), 1830-1835, 2005 | 56 | 2005 |
X-ray induced luminescence and spatial resolution of phosphor screens I Kandarakis, D Cavouras, G Panayiotakis, T Agelis, C Nomicos, ... Physics in Medicine & Biology 41 (2), 297, 1996 | 55 | 1996 |
Determination of the detective quantum efficiency (DQE) of CMOS/CsI imaging detectors following the novel IEC 62220-1-1: 2015 International Standard C Michail, I Valais, N Martini, V Koukou, N Kalyvas, A Bakas, I Kandarakis, ... Radiation Measurements 94, 8-17, 2016 | 53 | 2016 |
X-ray luminescence of ZnSCdS: Au, Cu phosphor using X-ray beams for medical applications I Kandarakis, D Cavouras, CD Nomicos, GS Panayiotakis Nuclear Instruments and Methods in Physics Research Section B: Beam …, 2001 | 52 | 2001 |
On the response of Y3Al5O12: Ce (YAG: Ce) powder scintillating screens to medical imaging X-rays I Kandarakis, D Cavouras, I Sianoudis, D Nikolopoulos, A Episkopakis, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2005 | 49 | 2005 |
Light emission efficiency and imaging performance of Lu2O3: Eu nanophosphor under X-ray radiography conditions: Comparison with Gd2O2S: Eu I Seferis, C Michail, I Valais, J Zeler, P Liaparinos, G Fountos, N Kalyvas, ... Journal of Luminescence 151, 229-234, 2014 | 48 | 2014 |
Experimental measurement of a high resolution CMOS detector coupled to CsI scintillators under X-ray radiation C Michail, I Valais, I Seferis, N Kalyvas, G Fountos, I Kandarakis Radiation Measurements 74, 39-46, 2015 | 47 | 2015 |
Measurement of the luminescence properties of Gd2O2S: Pr, Ce, F powder scintillators under X-ray radiation C Michail, I Valais, I Seferis, N Kalyvas, S David, G Fountos, I Kandarakis Radiation measurements 70, 59-64, 2014 | 47 | 2014 |
Experimental determination of detector gain, zero frequency detective quantum efficiency, and spectral compatibility of phosphor screens: comparison of CsI: Na and Gd2O2S: Tb … I Kandarakis, D Cavouras, E Kanellopoulos, CD Nomicos, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 1998 | 46 | 1998 |
Luminescence efficiency of calcium tungstate (CaWO4) under X-ray radiation: Comparison with Gd2O2S: Tb C Michail, I Valais, G Fountos, A Bakas, C Fountzoula, N Kalyvas, ... Measurement 120, 213-220, 2018 | 45 | 2018 |
Evaluation of ZnS: Cu phosphor as X-ray to light converter under mammographic conditions I Kandarakis, D Cavouras, D Nikolopoulos, A Anastasiou, ... Radiation measurements 39 (3), 263-275, 2005 | 45 | 2005 |