Consensus-based technical recommendations for clinical translation of renal ASL MRI F Nery, CE Buchanan, AA Harteveld, A Odudu, O Bane, EF Cox, K Derlin, ... Magnetic Resonance Materials in Physics, Biology and Medicine 33, 141-161, 2020 | 132 | 2020 |
Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE‐MRI: Results from a multicenter phantom study O Bane, SJ Hectors, M Wagner, LL Arlinghaus, MP Aryal, Y Cao, ... Magnetic resonance in medicine 79 (5), 2564-2575, 2018 | 98 | 2018 |
Quantification of hepatocellular carcinoma heterogeneity with multiparametric magnetic resonance imaging SJ Hectors, M Wagner, O Bane, C Besa, S Lewis, R Remark, N Chen, ... Scientific reports 7 (1), 2452, 2017 | 95 | 2017 |
Consensus-based technical recommendations for clinical translation of renal diffusion-weighted MRI A Ljimani, A Caroli, C Laustsen, S Francis, IA Mendichovszky, O Bane, ... Magnetic Resonance Materials in Physics, Biology and Medicine 33, 177-195, 2020 | 93 | 2020 |
Consensus-based technical recommendations for clinical translation of renal T1 and T2 mapping MRI IA Dekkers, A de Boer, K Sharma, EF Cox, HJ Lamb, DL Buckley, O Bane, ... Magnetic Resonance Materials in Physics, Biology and Medicine 33, 163-176, 2020 | 88 | 2020 |
MR Elastography of the liver: qualitative and quantitative comparison of gradient echo and spin echo echoplanar imaging sequences M Wagner, C Besa, JB Ayache, TK Yasar, O Bane, M Fung, RL Ehman, ... Investigative radiology 51 (9), 575, 2016 | 79* | 2016 |
Consensus-based technical recommendations for clinical translation of renal BOLD MRI O Bane, IA Mendichovszky, B Milani, IA Dekkers, JF Deux, P Eckerbom, ... Magnetic Resonance Materials in Physics, Biology and Medicine 33, 199-215, 2020 | 77 | 2020 |
Interplatform reproducibility of liver and spleen stiffness measured with MR elastography TK Yasar, M Wagner, O Bane, C Besa, JS Babb, S Kannengiesser, ... Journal of Magnetic Resonance Imaging 43 (5), 1064-1072, 2016 | 76 | 2016 |
Technical recommendations for clinical translation of renal MRI: a consensus project of the Cooperation in Science and Technology Action PARENCHIMA I Mendichovszky, P Pullens, I Dekkers, F Nery, O Bane, A Pohlmann, ... Magnetic Resonance Materials in Physics, Biology and Medicine 33, 131-140, 2020 | 71 | 2020 |
Prospective comparison of magnetic resonance imaging to transient elastography and serum markers for liver fibrosis detection HA Dyvorne, GH Jajamovich, O Bane, MI Fiel, H Chou, TD Schiano, ... Liver International 36 (5), 659-666, 2016 | 71 | 2016 |
Intravoxel incoherent motion diffusion‐weighted imaging of hepatocellular carcinoma: Is there a correlation with flow and perfusion metrics obtained with dynamic contrast … SJ Hectors, M Wagner, C Besa, O Bane, HA Dyvorne, MI Fiel, H Zhu, ... Journal of Magnetic Resonance Imaging 44 (4), 856-864, 2016 | 66 | 2016 |
Noninvasive prediction of portal pressure with MR elastography and DCE‐MRI of the liver and spleen: preliminary results M Wagner, S Hectors, O Bane, S Gordic, P Kennedy, C Besa, TD Schiano, ... Journal of magnetic resonance imaging 48 (4), 1091-1103, 2018 | 60 | 2018 |
3D T1 relaxometry pre and post gadoxetic acid injection for the assessment of liver cirrhosis and liver function C Besa, O Bane, G Jajamovich, J Marchione, B Taouli Magnetic Resonance Imaging 33 (9), 1075-1082, 2015 | 58 | 2015 |
Value of tumor stiffness measured with MR elastography for assessment of response of hepatocellular carcinoma to locoregional therapy S Gordic, JB Ayache, P Kennedy, C Besa, M Wagner, O Bane, RL Ehman, ... Abdominal Radiology 42, 1685-1694, 2017 | 54 | 2017 |
Assessment of renal function using intravoxel incoherent motion diffusion‐weighted imaging and dynamic contrast‐enhanced MRI O Bane, M Wagner, JL Zhang, HA Dyvorne, M Orton, H Rusinek, B Taouli Journal of Magnetic Resonance Imaging 44 (2), 317-326, 2016 | 52 | 2016 |
Multiparametric magnetic resonance imaging shows promising results to assess renal transplant dysfunction with fibrosis O Bane, SJ Hectors, S Gordic, P Kennedy, M Wagner, A Weiss, R Khaim, ... Kidney international 97 (2), 414-420, 2020 | 47 | 2020 |
Characterization of solid renal neoplasms using MRI-based quantitative radiomics features D Said, SJ Hectors, E Wilck, A Rosen, D Stocker, O Bane, AT Beksaç, ... Abdominal Radiology 45, 2840-2850, 2020 | 43 | 2020 |
Hemodynamic measurements with an abdominal 4D flow MRI sequence with spiral sampling and compressed sensing in patients with chronic liver disease O Bane, S Peti, M Wagner, S Hectors, H Dyvorne, M Markl, B Taouli Journal of Magnetic Resonance Imaging 49 (4), 994-1005, 2019 | 37 | 2019 |
Precision of MRI radiomics features in the liver and hepatocellular carcinoma G Carbonell, P Kennedy, O Bane, A Kirmani, M El Homsi, D Stocker, ... European Radiology, 1-11, 2022 | 34 | 2022 |
Diffusion and perfusion MRI quantification in ileal Crohn’s disease SJ Hectors, S Gordic, S Semaan, O Bane, R Hirten, X Jia, JF Colombel, ... European Radiology 29, 993-1002, 2019 | 33 | 2019 |