关注
Sebastian Käppler
Sebastian Käppler
Siemens Healthineers
在 fau.de 的电子邮件经过验证
标题
引用次数
引用次数
年份
Improved reconstruction of phase-stepping data for Talbot–Lau x-ray imaging
S Kaeppler, J Rieger, G Pelzer, F Horn, T Michel, A Maier, G Anton, ...
Journal of Medical Imaging 4 (3), 034005-034005, 2017
332017
Implementation of a Talbot-Lau interferometer in a clinical-like c-arm setup: A feasibility study
F Horn, M Leghissa, S Kaeppler, G Pelzer, J Rieger, M Seifert, J Wandner, ...
Scientific reports 8 (1), 2325, 2018
322018
Optimisation of image reconstruction for phase-contrast x-ray Talbot–Lau imaging with regard to mechanical robustness
M Seifert, S Kaeppler, C Hauke, F Horn, G Pelzer, J Rieger, T Michel, ...
Physics in Medicine & Biology 61 (17), 6441, 2016
312016
High-energy x-ray Talbot–Lau radiography of a human knee
F Horn, K Gelse, S Jabari, C Hauke, S Kaeppler, V Ludwig, P Meyer, ...
Physics in Medicine & Biology 62 (16), 6729, 2017
202017
Talbot-Lau x-ray phase-contrast setup for fast scanning of large samples
M Seifert, V Ludwig, S Kaeppler, F Horn, P Meyer, G Pelzer, J Rieger, ...
Scientific reports 9 (1), 4199, 2019
172019
Signal decomposition for x-ray dark-field imaging
S Kaeppler, F Bayer, T Weber, A Maier, G Anton, J Hornegger, ...
Medical Image Computing and Computer-Assisted Intervention–MICCAI 2014: 17th …, 2014
172014
Motion estimation model for cardiac and respiratory motion compensation
S Kaeppler, A Brost, M Koch, W Wu, F Bourier, T Chen, K Kurzidim, ...
Information Processing in Computer-Assisted Interventions: Third …, 2012
82012
Truncation correction for x-ray phase-contrast region-of-interest tomography
L Felsner, S Kaeppler, A Maier, C Riess
IEEE Transactions on Computational Imaging 6, 625-639, 2020
52020
Shading correction for grating-based differential phase contrast x-ray imaging
S Kaeppler, J Wandner, T Weber, A Maier, G Anton, J Hornegger, C Riess
2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2014
42014
Talbot‐Lau X‐ray phase contrast for tiling‐based acquisitions without reference scanning
S Kaeppler, M Seifert, F Horn, G Pelzer, J Rieger, T Michel, A Maier, ...
Medical Physics 44 (5), 1886-1898, 2017
32017
Method and system for motion estimation model for cardiac and respiratory motion compensation
AB Brost, S Kaeppler, M Ostermeier, N Strobel, W Wu, T Chen
US Patent 10,390,754, 2019
12019
Phase-sensitive region-of-interest computed tomography
L Felsner, M Berger, S Kaeppler, J Bopp, V Ludwig, T Weber, G Pelzer, ...
Medical Image Computing and Computer Assisted Intervention–MICCAI 2018: 21st …, 2018
12018
Polychromatic Maximum Likelihood Reconstruction for Talbot-Lau X-ray Tomography
F Schiffers, S Kaeppler, G Pelzer, A Wolf, A Maier, G Anton, C Riess
Fully3D 2017 Proceedings, 221-227, 2017
12017
Semi-automatic catheter model generation using biplane x-ray images
S Kaeppler, W Wu, T Chen, M Koch, AP Kiraly, N Strobel, J Hornegger
2013 IEEE 10th International Symposium on Biomedical Imaging, 1416-1419, 2013
12013
X-ray Phase Contrast: Research on a Future Imaging Modality
J Bopp, L Felsner, S Hu, S Kaeppler, C Riess
Medical Imaging Systems: An Introductory Guide, 191-205, 2018
2018
Non-destructive material testing using lattice-based phase-contrast X-ray imaging
V Ludwig, M Gallersdoerfer, S Kaeppler, G Pelzer, J Rieger, C Riess, ...
Differential Tomography: Influence of Sensitivity Direction and Noise-suppressing Windows
S Kaeppler, A Maier, C Riess
系统目前无法执行此操作,请稍后再试。
文章 1–17