Equations for calculation of chromatographic figures of merit for ideal and skewed peaks JP Foley, JG Dorsey Analytical Chemistry 55 (4), 730-737, 1983 | 808 | 1983 |
Effect of sampling rate on resolution in comprehensive two-dimensional liquid chromatography RE Murphy, MR Schure, JP Foley Analytical Chemistry 70 (8), 1585-1594, 1998 | 610 | 1998 |
A review of the exponentially modified gaussian (EMG) function: evaluation and subsequent calculation of universal data JP Foley, JG Dorsey Journal of chromatographic science 22 (1), 40-46, 1984 | 245 | 1984 |
Clarification of the limit of detection in chromatography JP Foley, JG Dorsey Chromatographia 18, 503-511, 1984 | 196 | 1984 |
Optimization of micellar electrokinetic chromatography JP Foley Analytical Chemistry 62 (13), 1302-1308, 1990 | 189 | 1990 |
Review of the exponentially modified Gaussian (EMG) function since 1983 MS Jeansonne, JP Foley Journal of chromatographic science 29 (6), 258-266, 1991 | 164 | 1991 |
Reduction in matrix-related signal suppression effects in electrospray ionization mass spectrometry using on-line two-dimensional liquid chromatography R Pascoe, JP Foley, AI Gusev Analytical chemistry 73 (24), 6014-6023, 2001 | 162 | 2001 |
One-and two-dimensional chromatographic analysis of alcohol ethoxylates RE Murphy, MR Schure, JP Foley Analytical Chemistry 70 (20), 4353-4360, 1998 | 147 | 1998 |
Equations for chromatographic peak modeling and calculation of peak area JP Foley Analytical chemistry 59 (15), 1984-1987, 1987 | 136 | 1987 |
Critical compilation of solute-micelle binding constants and related parameters from micellar liquid chromatographic measurements JP Foley Analytica Chimica Acta 231, 237-247, 1990 | 131 | 1990 |
Liquid chromatography: theory and methodology JG Dorsey, WT Cooper, JF Wheeler, HG Barth, JP Foley Analytical chemistry 66 (12), 500-546, 1994 | 123* | 1994 |
Determination of octanol–water partition coefficients of pesticides by microemulsion electrokinetic chromatography WL Klotz, MR Schure, JP Foley Journal of Chromatography A 930 (1-2), 145-154, 2001 | 119 | 2001 |
Electrokinetic chromatography using thermodynamically stable vesicles and mixed micelles formed from oppositely charged surfactants M Hong, BS Weekley, SJ Grieb, JP Foley Analytical chemistry 70 (7), 1394-1403, 1998 | 92 | 1998 |
Micellar electrokinetic capillary chromatography theory based on electrochemical parameters: optimization for three modes of operation K Ghowsi, JP Foley, RJ Gale Analytical chemistry 62 (24), 2714-2721, 1990 | 92 | 1990 |
Factors influencing the separation of oligonucleotides using reversed-phase/ion-exchange mixed-mode high performance liquid chromatography columns M Biba, E Jiang, B Mao, D Zewge, JP Foley, CJ Welch Journal of Chromatography A 1304, 69-77, 2013 | 85 | 2013 |
Infinite elution range in micellar electrokinetic capillary chromatography using a nonionic/anionic mixed micellar system ES Ahuja, KR Nielsen, JP Foley, EL Little Analytical Chemistry 67 (1), 26-33, 1995 | 78 | 1995 |
Optimization of secondary chemical equilibria in liquid chromatography: theory and verification JP Foley, WE May Analytical Chemistry 59 (1), 102-109, 1987 | 74 | 1987 |
Enantiomeric separations of basic pharmaceutical drugs by micellar electrokinetic chromatography using a chiral surfactant, N-dodecoxycarbonylvaline AG Peterson, ES Ahuja, JP Foley Journal of Chromatography B: Biomedical Sciences and Applications 683 (1), 15-28, 1996 | 71 | 1996 |
Influence of dodecyl sulfate counterion on efficiency, selectivity, retention, elution range, and resolution in micellar electrokinetic chromatography ES Ahuja, JP Foley Analytical Chemistry 67 (14), 2315-2324, 1995 | 65 | 1995 |
Optimization of the resolution of PTH‐amino acids through control of surfactant concentration in micellar electrokinetic capillary chromatography: SDS vs. brij 35 … EL Little, JP Foley Journal of Microcolumn Separations 4 (2), 145-154, 1992 | 65 | 1992 |