Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy A Mirandola, S Molinelli, G Vilches Freixas, A Mairani, E Gallio, D Panizza, ... Medical physics 42 (9), 5287-5300, 2015 | 155 | 2015 |
Dosimetric accuracy assessment of a treatment plan verification system for scanned proton beam radiotherapy: one-year experimental results and Monte Carlo analysis of the … S Molinelli, A Mairani, A Mirandola, GV Freixas, T Tessonnier, ... Physics in Medicine & Biology 58 (11), 3837, 2013 | 84 | 2013 |
Quality assurance multicenter comparison of different MR scanners for quantitative diffusion‐weighted imaging G Belli, S Busoni, A Ciccarone, A Coniglio, M Esposito, M Giannelli, ... Journal of Magnetic Resonance Imaging 43 (1), 213-219, 2016 | 79 | 2016 |
Beam commissioning of the first compact proton therapy system with spot scanning and dynamic field collimation G Vilches-Freixas, M Unipan, I Rinaldi, J Martens, E Roijen, IP Almeida, ... The British journal of radiology 93 (1107), 20190598, 2020 | 44 | 2020 |
Decomposing a prior-CT-based cone-beam CT projection correction algorithm into scatter and beam hardening components C Zöllner, S Rit, C Kurz, G Vilches-Freixas, F Kamp, G Dedes, C Belka, ... Physics and Imaging in Radiation Oncology 3, 49-52, 2017 | 40 | 2017 |
Comparison of projection- and image-based methods for proton stopping power estimation using dual energy CT G Vilches-Freixas, VT Taasti, LP Muren, JBB Petersen, JM Létang, ... Physics and Imaging in Radiation Oncology 3 (July), 28-36, 2017 | 32 | 2017 |
Multiple 3D inversion recovery imaging for volume T1 mapping of the heart A Coniglio, P Di Renzi, G Vilches Freixas, G Della Longa, A Santarelli, ... Magnetic resonance in medicine 69 (1), 163-170, 2013 | 32 | 2013 |
Proton beam radiotherapy: report of the first ten patients treated at the “Centro Nazionale di Adroterapia Oncologica (CNAO)” for skull base and spine tumours R Orecchia, V Vitolo, MR Fiore, P Fossati, A Iannalfi, B Vischioni, ... La radiologia medica 119, 277-282, 2014 | 30 | 2014 |
In vivo radiobiological assessment of the new clinical carbon ion beams at CNAO A Facoetti, B Vischioni, M Ciocca, M Ferrarini, Y Furusawa, A Mairani, ... Radiation protection dosimetry 166 (1-4), 379-382, 2015 | 19 | 2015 |
Development and application of tools for Monte Carlo based simulations in a particle beam radiotherapy facility T Tessonnier, A Mairani, F Cappucci, A Mirandola, GV Freixas, S Molinelli, ... Applied Radiation and Isotopes 83, 155-158, 2014 | 19 | 2014 |
A Monte Carlo based scatter removal method for non-isocentric cone-beam CT acquisitions using a deep convolutional autoencoder B Van Der Heyden, M Uray, GP Fonseca, P Huber, D Us, I Messner, ... Physics in Medicine & Biology 65 (14), 145002, 2020 | 17 | 2020 |
Visually guided inspiration breath-hold facilitated with nasal high flow therapy in locally advanced lung cancer STH Peeters, F Vaassen, C Hazelaar, A Vaniqui, E Rousch, D Tissen, ... Acta Oncologica 60 (5), 567-574, 2021 | 14 | 2021 |
Joint EURADOS WG9-WG11 rem-counter intercomparison in a Mevion S250i proton therapy facility with Hyperscan pulsed synchrocyclotron G Zorloni, G Bosmans, T Brall, M Caresana, M De Saint-Hubert, ... Physics in Medicine & Biology 67 (7), 075005, 2022 | 10 | 2022 |
Optimization of dual‐energy CT acquisitions for proton therapy using projection‐based decomposition G Vilches‐Freixas, JM Létang, N Ducros, S Rit Medical Physics 44 (9), 4548-4558, 2017 | 10 | 2017 |
Results of an independent dosimetry audit for scanned proton beam therapy facilities A Carlino, H Palmans, C Gouldstone, P Trnkova, O Noerrevang, ... Zeitschrift für Medizinische Physik 31 (2), 145-153, 2021 | 9 | 2021 |
Treatment planning comparison in the PROTECT-trial randomising proton versus photon beam therapy in oesophageal cancer: Results from eight European centres L Hoffmann, H Mortensen, M Shamshad, M Berbee, N Bizzocchi, R Bütof, ... Radiotherapy and Oncology 172, 32-41, 2022 | 7 | 2022 |
Procedure for the calibration and validation of kilo‐voltage cone‐beam CT models G Vilches‐Freixas, JM Létang, S Brousmiche, E Romero, M Vila Oliva, ... Medical Physics 43 (9), 5199-5204, 2016 | 7 | 2016 |
Implementation of a compact spot-scanning proton therapy system in a GPU Monte Carlo code to support clinical routine J Gajewski, A Schiavi, N Krah, G Vilches-Freixas, A Rucinski, V Patera, ... Frontiers in Physics 8, 578605, 2020 | 6* | 2020 |
A comparison study between single-and dual-energy CT density extraction methods for neurological proton monte carlo treatment planning B van der Heyden, IP Almeida, G Vilches-Freixas, C Van Beveren, ... Acta Oncologica 59 (2), 171-179, 2020 | 5 | 2020 |
Deriving the mean excitation energy map from dual-energy and proton computed tomography G Vilches-Freixas, CT Quiñones, JM Létang, S Rit Physics and imaging in radiation oncology 6, 20-24, 2018 | 5 | 2018 |