Fully integrated biochip platforms for advanced healthcare S Carrara, S Ghoreishizadeh, J Olivo, I Taurino, C Baj-Rossi, A Cavallini, ... Sensors 12 (8), 11013-11060, 2012 | 94 | 2012 |
Highly-stable Li+ ion-selective electrodes based on noble metal nanostructured layers as solid-contacts F Criscuolo, I Taurino, F Stradolini, S Carrara, G De Micheli Analytica chimica acta 1027, 22-32, 2018 | 83 | 2018 |
Fast synthesis of platinum nanopetals and nanospheres for highly-sensitive non-enzymatic detection of glucose and selective sensing of ions I Taurino, G Sanzó, F Mazzei, G Favero, G De Micheli, S Carrara Scientific reports 5 (1), 1-10, 2015 | 76 | 2015 |
Comparison of two different carbon nanotube-based surfaces with respect to potassium ferricyanide electrochemistry I Taurino, S Carrara, M Giorcelli, A Tagliaferro, G De Micheli Surface Science 606 (3-4), 156-160, 2012 | 75 | 2012 |
A differential electrochemical readout ASIC with heterogeneous integration of bio-nano sensors for amperometric sensing SS Ghoreishizadeh, I Taurino, G De Micheli, S Carrara, P Georgiou IEEE transactions on biomedical circuits and systems 11 (5), 1148-1159, 2017 | 72 | 2017 |
Bubble electrodeposition of gold porous nanocorals for the enzymatic and non-enzymatic detection of glucose G Sanzó, I Taurino, R Antiochia, L Gorton, G Favero, F Mazzei, ... Bioelectrochemistry 112, 125-131, 2016 | 72 | 2016 |
Wearable multifunctional sweat-sensing system for efficient healthcare monitoring F Criscuolo, IN Hanitra, S Aiassa, I Taurino, N Oliva, S Carrara, ... Sensors and Actuators B: Chemical 328, 129017, 2021 | 71 | 2021 |
Recent advances in third generation biosensors based on Au and Pt nanostructured electrodes I Taurino, G Sanzò, R Antiochia, C Tortolini, F Mazzei, G Favero, ... TrAC Trends in Analytical Chemistry 79, 151-159, 2016 | 60 | 2016 |
Google glass-directed monitoring and control of microfluidic biosensors and actuators YS Zhang, F Busignani, J Ribas, J Aleman, TN Rodrigues, SAM Shaegh, ... Scientific reports 6 (1), 22237, 2016 | 47 | 2016 |
Comparative study of three lactate oxidases from Aerococcus viridans for biosensing applications I Taurino, R Reiss, M Richter, M Fairhead, L Thöny-Meyer, G De Micheli, ... Electrochimica Acta 93, 72-79, 2013 | 47 | 2013 |
Tracing the composition of single e-cigarette aerosol droplets in situ by laser-trapping and Raman scattering G David, EA Parmentier, I Taurino, R Signorell Scientific reports 10 (1), 1-8, 2020 | 44 | 2020 |
Biodegradable molybdenum (mo) and tungsten (w) devices: One step closer towards fully-transient biomedical implants C Fernandes, I Taurino Sensors 22 (8), 3062, 2022 | 36 | 2022 |
Superior sensing performance of multi-walled carbon nanotube-based electrodes to detect unconjugated bilirubin I Taurino, V Van Hoof, G De Micheli, S Carrara Thin Solid Films 548, 546-550, 2013 | 36 | 2013 |
Cleaning strategy for carbon-based electrodes: Long-term propofol monitoring in human serum F Stradolini, T Kilic, I Taurino, G De Micheli, S Carrara Sensors and Actuators B: Chemical 269, 304-313, 2018 | 34 | 2018 |
Nickel-based catalysts for non-enzymatic electrochemical sensing of glucose: A review F Franceschini, I Taurino Physics in Medicine 14, 100054, 2022 | 32 | 2022 |
All-solid-state ion-selective electrodes: A tutorial for correct practice F Criscuolo, MIN Hanitra, I Taurino, S Carrara, G De Micheli IEEE Sensors Journal 21 (20), 22143-22154, 2021 | 28 | 2021 |
High-performance multipanel biosensors based on a selective integration of nanographite petals I Taurino, A Magrez, F Matteini, A Cavallini, L Forró, G De Micheli, ... Nano letters 14 (6), 3180-3184, 2014 | 26 | 2014 |
Study on the bio-functionalization of memristive nanowires for optimum memristive biosensors I Tzouvadaki, N Madaboosi, I Taurino, V Chu, JP Conde, G De Micheli, ... Journal of Materials Chemistry B 4 (12), 2153-2162, 2016 | 24 | 2016 |
Efficient voltammetric discrimination of free bilirubin from uric acid and ascorbic acid by a CVD nanographite-based microelectrode I Taurino, V Van Hoof, A Magrez, L Forró, G De Micheli, S Carrara Talanta 130, 423-426, 2014 | 22 | 2014 |
Comparing sensitivities of differently oriented multi-walled carbon nanotubes integrated on silicon wafer for electrochemical biosensors I Taurino, S Carrara, M Giorcelli, A Tagliaferro, G De Micheli Sensors and Actuators B: Chemical 160 (1), 327-333, 2011 | 22 | 2011 |