关注
Irene Taurino
Irene Taurino
Professor KU Leuven
没有经过验证的电子邮件地址 - 首页
标题
引用次数
引用次数
年份
Fully integrated biochip platforms for advanced healthcare
S Carrara, S Ghoreishizadeh, J Olivo, I Taurino, C Baj-Rossi, A Cavallini, ...
Sensors 12 (8), 11013-11060, 2012
942012
Highly-stable Li+ ion-selective electrodes based on noble metal nanostructured layers as solid-contacts
F Criscuolo, I Taurino, F Stradolini, S Carrara, G De Micheli
Analytica chimica acta 1027, 22-32, 2018
832018
Fast synthesis of platinum nanopetals and nanospheres for highly-sensitive non-enzymatic detection of glucose and selective sensing of ions
I Taurino, G Sanzó, F Mazzei, G Favero, G De Micheli, S Carrara
Scientific reports 5 (1), 1-10, 2015
762015
Comparison of two different carbon nanotube-based surfaces with respect to potassium ferricyanide electrochemistry
I Taurino, S Carrara, M Giorcelli, A Tagliaferro, G De Micheli
Surface Science 606 (3-4), 156-160, 2012
752012
A differential electrochemical readout ASIC with heterogeneous integration of bio-nano sensors for amperometric sensing
SS Ghoreishizadeh, I Taurino, G De Micheli, S Carrara, P Georgiou
IEEE transactions on biomedical circuits and systems 11 (5), 1148-1159, 2017
722017
Bubble electrodeposition of gold porous nanocorals for the enzymatic and non-enzymatic detection of glucose
G Sanzó, I Taurino, R Antiochia, L Gorton, G Favero, F Mazzei, ...
Bioelectrochemistry 112, 125-131, 2016
722016
Wearable multifunctional sweat-sensing system for efficient healthcare monitoring
F Criscuolo, IN Hanitra, S Aiassa, I Taurino, N Oliva, S Carrara, ...
Sensors and Actuators B: Chemical 328, 129017, 2021
712021
Recent advances in third generation biosensors based on Au and Pt nanostructured electrodes
I Taurino, G Sanzò, R Antiochia, C Tortolini, F Mazzei, G Favero, ...
TrAC Trends in Analytical Chemistry 79, 151-159, 2016
602016
Google glass-directed monitoring and control of microfluidic biosensors and actuators
YS Zhang, F Busignani, J Ribas, J Aleman, TN Rodrigues, SAM Shaegh, ...
Scientific reports 6 (1), 22237, 2016
472016
Comparative study of three lactate oxidases from Aerococcus viridans for biosensing applications
I Taurino, R Reiss, M Richter, M Fairhead, L Thöny-Meyer, G De Micheli, ...
Electrochimica Acta 93, 72-79, 2013
472013
Tracing the composition of single e-cigarette aerosol droplets in situ by laser-trapping and Raman scattering
G David, EA Parmentier, I Taurino, R Signorell
Scientific reports 10 (1), 1-8, 2020
442020
Biodegradable molybdenum (mo) and tungsten (w) devices: One step closer towards fully-transient biomedical implants
C Fernandes, I Taurino
Sensors 22 (8), 3062, 2022
362022
Superior sensing performance of multi-walled carbon nanotube-based electrodes to detect unconjugated bilirubin
I Taurino, V Van Hoof, G De Micheli, S Carrara
Thin Solid Films 548, 546-550, 2013
362013
Cleaning strategy for carbon-based electrodes: Long-term propofol monitoring in human serum
F Stradolini, T Kilic, I Taurino, G De Micheli, S Carrara
Sensors and Actuators B: Chemical 269, 304-313, 2018
342018
Nickel-based catalysts for non-enzymatic electrochemical sensing of glucose: A review
F Franceschini, I Taurino
Physics in Medicine 14, 100054, 2022
322022
All-solid-state ion-selective electrodes: A tutorial for correct practice
F Criscuolo, MIN Hanitra, I Taurino, S Carrara, G De Micheli
IEEE Sensors Journal 21 (20), 22143-22154, 2021
282021
High-performance multipanel biosensors based on a selective integration of nanographite petals
I Taurino, A Magrez, F Matteini, A Cavallini, L Forró, G De Micheli, ...
Nano letters 14 (6), 3180-3184, 2014
262014
Study on the bio-functionalization of memristive nanowires for optimum memristive biosensors
I Tzouvadaki, N Madaboosi, I Taurino, V Chu, JP Conde, G De Micheli, ...
Journal of Materials Chemistry B 4 (12), 2153-2162, 2016
242016
Efficient voltammetric discrimination of free bilirubin from uric acid and ascorbic acid by a CVD nanographite-based microelectrode
I Taurino, V Van Hoof, A Magrez, L Forró, G De Micheli, S Carrara
Talanta 130, 423-426, 2014
222014
Comparing sensitivities of differently oriented multi-walled carbon nanotubes integrated on silicon wafer for electrochemical biosensors
I Taurino, S Carrara, M Giorcelli, A Tagliaferro, G De Micheli
Sensors and Actuators B: Chemical 160 (1), 327-333, 2011
222011
系统目前无法执行此操作,请稍后再试。
文章 1–20