关注
WENTAI LIU
WENTAI LIU
在 g.ucla.edu 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Retinal prosthesis
JD Weiland, W Liu, MS Humayun
Annu. Rev. Biomed. Eng. 7 (1), 361-401, 2005
5982005
Retinal prosthesis for the blind
E Margalit, M Maia, JD Weiland, RJ Greenberg, GY Fujii, G Torres, ...
Survey of ophthalmology 47 (4), 335-356, 2002
5902002
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
W Liu, K Vichienchom, M Clements, SC DeMarco, C Hughes, ...
IEEE Journal of Solid-State Circuits 35 (10), 1487-1497, 2000
5782000
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
G Wang, W Liu, M Sivaprakasam, GA Kendir
IEEE Transactions on Circuits and Systems I: Regular Papers 52 (10), 2109-2117, 2005
5612005
A 128-channel 6 mW wireless neural recording IC with spike feature extraction and UWB transmitter
MS Chae, Z Yang, MR Yuce, L Hoang, W Liu
IEEE transactions on neural systems and rehabilitation engineering 17 (4 …, 2009
4512009
Wave-pipelining: a tutorial and research survey
WP Burleson, M Ciesielski, F Klass, W Liu
IEEE Transactions on very large scale integration (vlsi) systems 6 (3), 464-474, 1998
3401998
An integrated 256-channel epiretinal prosthesis
K Chen, Z Yang, L Hoang, J Weiland, M Humayun, W Liu
IEEE Journal of Solid-State Circuits 45 (9), 1946-1956, 2010
3212010
An optimal design methodology for inductive power link with class-E amplifier
GA Kendir, W Liu, G Wang, M Sivaprakasam, R Bashirullah, MS Humayun, ...
IEEE Transactions on Circuits and Systems I: Regular Papers 52 (5), 857-866, 2005
2802005
A 128-channel 6mw wireless neural recording ic with on-the-fly spike sorting and uwb tansmitter
M Chae, W Liu, Z Yang, T Chen, J Kim, M Sivaprakasam, M Yuce
2008 IEEE International Solid-State Circuits Conference-Digest of Technical …, 2008
2582008
Wireless wearable big data brain machine interface
W Liu, MCF Chang, YC Kuan, YK Lo, Y Zhao
US Patent 10,027,362, 2018
2492018
Inductor modeling in wireless links for implantable electronics
Z Yang, W Liu, E Basham
IEEE Transactions on Magnetics 43 (10), 3851-3860, 2007
2412007
A variable range bi-phasic current stimulus driver circuitry for an implantable retinal prosthetic device
M Sivaprakasam, W Liu, MS Humayun, JD Weiland
IEEE Journal of Solid-State Circuits 40 (3), 763-771, 2005
2272005
Retinal prosthesis: an encouraging first decade with major challenges ahead
JF Rizzo, J Wyatt, M Humayun, E de Juan, W Liu, A Chow, R Eckmiller, ...
Ophthalmology 108 (1), 13-14, 2001
2172001
Stretchable, dynamic covalent polymers for soft, long-lived bioresorbable electronic stimulators designed to facilitate neuromuscular regeneration
YS Choi, YY Hsueh, J Koo, Q Yang, R Avila, B Hu, Z Xie, G Lee, Z Ning, ...
Nature communications 11 (1), 5990, 2020
1762020
Design optimization for integrated neural recording systems
MS Chae, W Liu, M Sivaprakasam
IEEE Journal of Solid-State Circuits 43 (9), 1931-1939, 2008
1472008
A dual band wireless power and data telemetry for retinal prosthesis
G Wang, W Liu, M Sivaprakasam, M Zhou, JD Weiland, MS Humayun
2006 International Conference of the IEEE Engineering in Medicine and …, 2006
1452006
Transparent arrays of bilayer-nanomesh microelectrodes for simultaneous electrophysiology and two-photon imaging in the brain
Y Qiang, P Artoni, KJ Seo, S Culaclii, V Hogan, X Zhao, Y Zhong, X Han, ...
Science advances 4 (9), eaat0626, 2018
1412018
Analysis of dual band power and data telemetry for biomedical implants
G Wang, P Wang, Y Tang, W Liu
IEEE Transactions on biomedical circuits and systems 6 (3), 208-215, 2011
1382011
Computed SAR and thermal elevation in a 0.25-mm 2-D model of the human eye and head in response to an implanted retinal stimulator-Part I: Models and methods
SC DeMarco, G Lazzi, W Liu, JD Weiland, MS Humayun
IEEE Transactions on Antennas and Propagation 51 (9), 2274-2285, 2003
1372003
Wireless body sensor network using medical implant band
MR Yuce, SWP Ng, NL Myo, JY Khan, W Liu
Journal of Medical Systems 31, 467-474, 2007
1262007
系统目前无法执行此操作,请稍后再试。
文章 1–20