Damage to inner ear structure during cochlear implantation: Correlation between insertion force and radio-histological findings in temporal bone specimens D De Seta, R Torres, FY Russo, E Ferrary, G Kazmitcheff, D Heymann, ... Hearing research 344, 90-97, 2017 | 81 | 2017 |
JavaProtein Dossier: a novel web-based data visualization tool for comprehensive analysis of protein structure G Neshich, W Rocchia, AL Mancini, MEB Yamagishi, PR Kuser, R Fileto, ... Nucleic Acids Research 32 (suppl_2), W595-W601, 2004 | 55 | 2004 |
Robot-based assistance in middle ear surgery and cochlear implantation: first clinical report S Vittoria, G Lahlou, R Torres, H Daoudi, I Mosnier, S Mazalaigue, ... European Archives of Oto-Rhino-Laryngology 278, 77-85, 2021 | 52 | 2021 |
Multivariate analysis of factors influencing facial nerve outcome following microsurgical resection of vestibular schwannoma R Torres, Y Nguyen, A Vanier, M Smail, E Ferrary, O Sterkers, ... Otolaryngology–Head and Neck Surgery 156 (3), 525-533, 2017 | 48 | 2017 |
Robot-assisted cochlear implant electrode array insertion in adults: a comparative study with manual insertion H Daoudi, G Lahlou, R Torres, O Sterkers, V Lefeuvre, E Ferrary, ... Otology & Neurotology 42 (4), e438-e444, 2021 | 43 | 2021 |
Cochlear implant insertion axis into the basal turn: a critical factor in electrode array translocation R Torres, M Drouillard, D De Seta, JL Bensimon, E Ferrary, O Sterkers, ... Otology & Neurotology 39 (2), 168-176, 2018 | 41 | 2018 |
Variability of the mental representation of the cochlear anatomy during cochlear implantation R Torres, G Kazmitcheff, D Bernardeschi, D De Seta, JL Bensimon, ... European Archives of Oto-Rhino-Laryngology 273, 2009-2018, 2016 | 36 | 2016 |
3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study D De Seta, P Mancini, FY Russo, R Torres, I Mosnier, JL Bensimon, ... Acta Otorhinolaryngologica Italica 36 (6), 499, 2016 | 35 | 2016 |
Intraoperative conebeam CT for assessment of intracochlear positioning of electrode arrays in adult recipients of cochlear implants H Jia, R Torres, Y Nguyen, D De Seta, E Ferrary, H Wu, O Sterkers, ... American Journal of Neuroradiology 39 (4), 768-774, 2018 | 34 | 2018 |
Improvement of the insertion axis for cochlear implantation with a robot-based system R Torres, G Kazmitcheff, D De Seta, E Ferrary, O Sterkers, Y Nguyen European Archives of Oto-Rhino-Laryngology 274 (2), 715-721, 2017 | 34 | 2017 |
An optimized robot-based technique for cochlear implantation to reduce array insertion trauma R Torres, H Jia, M Drouillard, JL Bensimon, O Sterkers, E Ferrary, ... Otolaryngology–Head and Neck Surgery 159 (5), 900-907, 2018 | 32 | 2018 |
Robotics, automation, active electrode arrays, and new devices for cochlear implantation: A contemporary review D De Seta, H Daoudi, R Torres, E Ferrary, O Sterkers, Y Nguyen Hearing Research 414, 108425, 2022 | 30 | 2022 |
Modifications to a 3D-printed temporal bone model for augmented stapes fixation surgery teaching Y Nguyen, E Mamelle, D De Seta, O Sterkers, D Bernardeschi, R Torres European Archives of Oto-Rhino-Laryngology 274 (7), 2733-2739, 2017 | 30 | 2017 |
Influence of electrode array stiffness and diameter on hearing in cochlear implanted guinea pig M Drouillard, R Torres, E Mamelle, D De Seta, O Sterkers, E Ferrary, ... PLoS One 12 (8), e0183674, 2017 | 28 | 2017 |
Atraumatic insertion of a cochlear implant pre-curved electrode array by a robot-automated alignment with the coiling direction of the scala tympani R Torres, B Hochet, H Daoudi, F Carré, I Mosnier, O Sterkers, E Ferrary, ... Audiology and Neurotology 27 (2), 148-155, 2022 | 15 | 2022 |
Restoration of high frequency auditory perception after robot-assisted or manual cochlear implantation in profoundly deaf adults improves speech recognition R Torres, H Daoudi, G Lahlou, O Sterkers, E Ferrary, I Mosnier, Y Nguyen Frontiers in Surgery 8, 729736, 2021 | 12 | 2021 |
Numerical simulation of cochlear-implant surgery: towards patient-specific planning O Goury, Y Nguyen, R Torres, J Dequidt, C Duriez Medical Image Computing and Computer-Assisted Intervention–MICCAI 2016: 19th …, 2016 | 9 | 2016 |
Pig as a large animal model for posterior fossa surgery in oto-neurosurgery: A cadaveric study M Elsayed, R Torres, O Sterkers, D Bernardeschi, Y Nguyen PloS one 14 (2), e0212855, 2019 | 8 | 2019 |
Best fit 3D basilar membrane reconstruction to routinely assess the scalar position of the electrode array after cochlear implantation R Torres, JY Tinevez, H Daoudi, G Lahlou, N Grislain, E Breil, O Sterkers, ... Journal of Clinical Medicine 11 (8), 2075, 2022 | 6 | 2022 |
Intraoperative facial nerve electromyography parameters to optimize postoperative facial nerve outcome in patients with large unilateral vestibular schwannoma M Elsayed, H Jia, B Hochet, O Sterkers, R Torres, Y Nguyen, I Bernat, ... Acta Neurochirurgica 163, 2209-2217, 2021 | 5 | 2021 |