Experimental study on natural ventilation of a room with a windward window and different windexchangers MV Cruz-Salas, JA Castillo, G Huelsz Energy and Buildings 84, 458-465, 2014 | 45 | 2014 |
A methodology to evaluate the indoor natural ventilation in hot climates: Heat Balance Index JA Castillo, G Huelsz Building and Environment 114, 366-373, 2017 | 32 | 2017 |
Natural ventilation of an isolated generic building with a windward window and different windexchangers: CFD validation, sensitivity study and performance analysis JA Castillo, G Huelsz, T van Hooff, B Blocken Building Simulation 12, 475-488, 2019 | 29 | 2019 |
Effect of windexchanger duct cross-section area and geometry on the room airflow distribution MV Cruz-Salas, JA Castillo, G Huelsz Journal of Wind Engineering and Industrial Aerodynamics 179, 514-523, 2018 | 28 | 2018 |
Flow generated by a thermal plume in a cooled-ceiling system LP Thomas, BM Marino, R Tovar, JA Castillo Energy and Buildings 43 (10), 2727-2736, 2011 | 19 | 2011 |
Transient cooling of a room with a chilled ceiling JA Castillo, R Tovar Solar Energy 86 (4), 1029-1036, 2012 | 16 | 2012 |
Energía y confort en edificaciones J Rojas, G Huelsz, R Tovar, G Barrios, A Lira-Oliver, A Castillo Revista Digital Universitaria 11 (10), 5, 2010 | 10 | 2010 |
Uso de sistemas pasivos de climatización en la zona de Temixco Morelos con clima cálido semi-húmedo JA Castillo, A Lira-Oliver, JJ Muñoz, CÁ Ramírez, SN Juárez, J Rojas, ... Memorias del XXXV SNES, 183-8, 2011 | 9 | 2011 |
Natural ventilation by windexchangers in a building with a window in prevailing winds: design guidelines JA Castillo, MV Cruz-Salas, G Huelsz International Journal of Ventilation 16 (1), 1-14, 2017 | 8 | 2017 |
Heat transfer by natural convection and radiation in three dimensional differentially heated tall cavities P Hernández-Castillo, JA Castillo, G Huelsz Case Studies in Thermal Engineering 40, 102529, 2022 | 7 | 2022 |
Evaluation of different window heights and facade porosities in naturally cross-ventilated buildings: CFD validation SF Díaz-Calderón, JA Castillo, G Huelsz Journal of Wind Engineering and Industrial Aerodynamics 232, 105263, 2023 | 6 | 2023 |
Convection generated by a small heat source in a box with a cooled upper contour at constant temperature LP Thomas, BM Marino, R Tovar, JA Castillo Journal of Physics: Conference Series 296 (1), 012022, 2011 | 6 | 2011 |
Indoor air quality evaluation in naturally cross-ventilated buildings for education using age of air SF Díaz-Calderón, JA Castillo, G Huelsz Journal of Physics: Conference Series 2069 (1), 012182, 2021 | 5 | 2021 |
Natural ventilation in a room with a horizontal cylindrical heat source, a window and bottom or top vents JA Castillo, R Tovar, G Huelsz Building and Environment 191, 107583, 2021 | 5 | 2021 |
Visualización de plumas y medición de gradientes térmicos por medio de schlieren sintético LP Thomas, BM Marino, R Tovar Olvera, JA Castillo, JA Rojas Menéndez Avances en Energías Renovables y Medio Ambiente 13, 2009 | 4 | 2009 |
Enfriamiento pasivo por techos fríos en habitaciones R Tovar, JA Castillo Memorias de la 33, 2009 | 3 | 2009 |
Flujos generados por una fuente de calor en un recinto con cielorraso a temperatura constante y aberturas LP Thomas, BM Marino, R Tovar Olvera, JA Castillo Avances en Energías Renovables y Medio Ambiente 15, 2011 | 2 | 2011 |
Indoor comfort evaluation by natural ventilation in hot climates: Heat Balance Index JA Castillo, G Huelsz Proceedings of 33rd PLEA International Conference: Design to Thrive, PLEA …, 2006 | 2 | 2006 |
Natural ventilation by windcatchers: CFD simulations and experiments JA Castillo, G Huelsz, MV Cruz Hamburg, Germany. CWE, 2014 | 1 | 2014 |
Modelado analítico de la ventilación en una habitación con cielorraso enfriado y fuente de calor, conectada al exterior LP Thomas, BM Marino, R Tovar, JA Castillo Avances en Energías Renovables y Medio Ambiente-AVERMA 16, 57-64, 2012 | 1 | 2012 |