Electro-acoustic performance of the new bone vibrator Radioear B81: A comparison with the conventional Radioear B71 KJF Jansson, B Håkansson, L Johannsen, T Tengstrand International journal of audiology 54 (5), 334-340, 2015 | 60 | 2015 |
The bone conduction implant: Clinical results of the first six patients S Reinfeldt, B Håkansson, H Taghavi, KJ Fredén Jansson, ... International Journal of Audiology 54 (6), 408-416, 2015 | 54 | 2015 |
The bone conduction implant—first implantation, surgical and audiologic aspects M Eeg-Olofsson, B Håkansson, S Reinfeldt, H Taghavi, H Lund, ... Otology & Neurotology 35 (4), 679-685, 2014 | 49 | 2014 |
Touch and hearing mediate osseoperception F Clemente, B Håkansson, C Cipriani, J Wessberg, K Kulbacka-Ortiz, ... Scientific Reports 7 (1), 45363, 2017 | 38 | 2017 |
Technical design of a new bone conduction implant (BCI) system H Taghavi, B Håkansson, S Reinfeldt, M Eeg-Olofsson, KJF Jansson, ... International journal of audiology 54 (10), 736-744, 2015 | 33 | 2015 |
The bone conduction implant–a review and 1-year follow-up B Håkansson, S Reinfeldt, AC Persson, KJF Jansson, C Rigato, ... International Journal of Audiology 58 (12), 945-955, 2019 | 32 | 2019 |
MRI induced torque and demagnetization in retention magnets for a bone conduction implant KJF Jansson, B Håkansson, S Reinfeldt, H Taghavi, M Eeg-Olofsson IEEE transactions on biomedical engineering 61 (6), 1887-1893, 2014 | 26 | 2014 |
Audiometric comparison between the first patients with the transcutaneous bone conduction implant and matched percutaneous bone anchored hearing device users C Rigato, S Reinfeldt, B Håkansson, KJF Jansson, MKS Hol, ... Otology & Neurotology 37 (9), 1381-1387, 2016 | 25 | 2016 |
Magnetic resonance imaging investigation of the bone conduction implant–a pilot study at 1.5 Tesla KJF Jansson, B Håkansson, S Reinfeldt, C Rigato, M Eeg-Olofsson Medical Devices: Evidence and Research, 413-423, 2015 | 25 | 2015 |
Effect of transducer attachment on vibration transmission and transcranial attenuation for direct drive bone conduction stimulation C Rigato, S Reinfeldt, B Håkansson, KJF Jansson, E Renvall, ... Hearing Research 381, 107763, 2019 | 21 | 2019 |
VEMP using a new low-frequency bone conduction transducer B Håkansson, KJF Jansson, T Tengstrand, L Johannsen, M Eeg-Olofsson, ... Medical Devices: Evidence and Research, 301-312, 2018 | 21 | 2018 |
Vibrotactile thresholds on the mastoid and forehead position of deaf patients using Radioear B71 and B81 KJF Jansson, B Håkansson, S Reinfeldt, L Fröhlich, T Rahne Ear and Hearing 38 (6), 714-723, 2017 | 16 | 2017 |
Direct bone conduction stimulation: ipsilateral effect of different transducer attachments in active transcutaneous devices C Rigato, S Reinfeldt, B Håkansson, KJF Jansson, E Renvall, ... Hearing Research 361, 103-112, 2018 | 14 | 2018 |
A novel method for objective in-situ measurement of audibility in bone conduction hearing devices–a pilot study using a skin drive BCD AC Persson, B Håkansson, M Caveramma Mechanda, W Bill Hodgetts, ... International Journal of Audiology 62 (4), 357-361, 2023 | 10 | 2023 |
Nasal sound pressure as objective verification of implant in active transcutaneous bone conduction devices S Reinfeldt, C Rigato, B Håkansson, KJ Fredén Jansson, M Eeg-Olofsson Medical Devices: Evidence and Research, 193-202, 2019 | 10 | 2019 |
Bone conduction stimulated VEMP using the B250 transducer KJ Fredén Jansson, B Håkansson, S Reinfeldt, AC Persson, ... Medical Devices: Evidence and Research, 225-237, 2021 | 9 | 2021 |
Three-year follow-up with the bone conduction implant AC Persson, S Reinfeldt, B Håkansson, C Rigato, KJ Fredén Jansson, ... Audiology and Neurotology 25 (5), 263-275, 2020 | 9 | 2020 |
Long-term follow-up and review of the Bone Conduction Implant S Reinfeldt, M Eeg-Olofsson, KJF Jansson, AC Persson, B Håkansson Hearing Research 421, 108503, 2022 | 6 | 2022 |
Robustness and lifetime of the bone conduction implant–a pilot study KJ Fredén Jansson, B Håkansson, C Rigato, M Eeg-Olofsson, S Reinfeldt Medical Devices: Evidence and Research, 89-100, 2019 | 6 | 2019 |
Evaluation of Bone Tissue Formation in a Flat Surface Attachment of a Bone Conduction Implant: A Pilot Study in a Sheep Model M Eeg-Olofsson, A Lith, B Håkansson, S Reinfeldt, H Taghavi, ... Audiology and Neurotology Extra 4 (3), 62-76, 2014 | 4 | 2014 |