Ambient desorption ionization mass spectrometry A Venter, M Nefliu, RG Cooks TrAC Trends in Analytical Chemistry 27 (4), 284-290, 2008 | 662 | 2008 |
Extractive electrospray ionization for direct analysis of undiluted urine, milk and other complex mixtures without sample preparation H Chen, A Venter, RG Cooks Chemical Communications, 2042-2044, 2006 | 482 | 2006 |
Droplet dynamics and ionization mechanisms in desorption electrospray ionization mass spectrometry A Venter, PE Sojka, RG Cooks Analytical Chemistry 78 (24), 8549-8555, 2006 | 403 | 2006 |
Ambient molecular imaging by desorption electrospray ionization mass spectrometry JM Wiseman, DR Ifa, A Venter, RG Cooks Nature Protocols 3 (3), 517-524, 2008 | 216 | 2008 |
Mechanisms of real-time, proximal sample processing during ambient ionization mass spectrometry AR Venter, KA Douglass, JT Shelley, G Hasman Jr, E Honarvar Analytical chemistry 86 (1), 233-249, 2014 | 168 | 2014 |
Internal energy distributions in desorption electrospray ionization (DESI) M Nefliu, JN Smith, A Venter, RG Cooks Journal of the American Society for Mass Spectrometry 19 (3), 420-427, 2008 | 124 | 2008 |
Ambient ionization mass spectrometry: real-time, proximal sample processing and ionization R Javanshad, AR Venter Analytical Methods 9, 4896-4907, 2017 | 112 | 2017 |
Desorption electrospray ionization in a small pressure-tight enclosure A Venter, RG Cooks Analytical chemistry 79 (16), 6398-6403, 2007 | 110 | 2007 |
Enclosed desorption electrospray ionization A Venter, RG Cooks US Patent 7,847,244, 2010 | 89 | 2010 |
Surface effects and electrochemical cell capacitance in desorption electrospray ionization M Volný, A Venter, SA Smith, M Pazzi, RG Cooks Analyst 133 (4), 525-531, 2008 | 87 | 2008 |
Reaction kinetics and efficiencies for the hydroxyl and sulfate radical based oxidation of artificial sweeteners in water JE Toth, KA Rickman, AR Venter, JJ Kiddle, SP Mezyk The Journal of Physical Chemistry A 116 (40), 9819-9824, 2012 | 83 | 2012 |
Desorption electrospray ionization and electrosonic spray ionization for solid-and solution-phase analysis of industrial polymers M Nefliu, A Venter, RG Cooks Chemical communications, 888-890, 2006 | 80 | 2006 |
Investigating the role of adducts in protein supercharging with sulfolane KA Douglass, AR Venter Journal of The American Society for Mass Spectrometry 23 (3), 489-497, 2012 | 73 | 2012 |
Protein analysis by desorption electrospray ionization mass spectrometry and related methods KA Douglass, AR Venter Journal of mass spectrometry 48 (5), 553-560, 2013 | 60 | 2013 |
Microspray liquid-liquid extractive ionization device H Chen, H Chen, A Venter, RG Cooks US Patent App. 11/751,718, 2008 | 43 | 2008 |
Deconstructing desorption electrospray ionization: independent optimization of desorption and ionization by spray desorption collection KA Douglass, S Jain, WR Brandt, AR Venter Journal of The American Society for Mass Spectrometry 23 (11), 1896-1902, 2012 | 42 | 2012 |
Surface sampling by spray-desorption followed by collection for chemical analysis AR Venter, A Kamali, S Jain, S Bairu Analytical chemistry 82 (5), 1674-1679, 2010 | 35 | 2010 |
Rhodamine Based Turn-On Sensors for Ni2+ and Cr3+ in Organic Media: Detecting CN− via the Metal Displacement Approach AJ Weerasinghe, AN Oyeamalu, FA Abebe, AR Venter, E Sinn Journal of fluorescence 26, 891-898, 2016 | 32 | 2016 |
Comprehensive two-dimensional supercritical fluid and gas chromatography with independent fast programmed heating of the gas chromatographic column A Venter, ER Rohwer Analytical chemistry 76 (13), 3699-3706, 2004 | 32 | 2004 |
Ammonium bicarbonate addition improves the detection of proteins by desorption electrospray ionization mass spectrometry E Honarvar, AR Venter Journal of The American Society for Mass Spectrometry 28 (6), 1109-1117, 2017 | 31 | 2017 |