Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans
YS Soliman, MI El Gohary, MHA Gawad, EA Amin, OS Desouky
Applied Radiation and Isotopes 120, 126-132, 2017
532017
Effect of perchloric acid on the performance of the Fricke xylenol gel dosimeter
MI El Gohary, YS Soliman, EA Amin, MHA Gawad, OS Desouky
Applied Radiation and Isotopes 113, 66-69, 2016
242016
Pergascript orange-based polymeric solution as a dosimeter for radiotherapy dosimetric validation
YS Soliman, WB Beshir, MH Abdelgawad, E Bräuer-Krisch, ...
Physica Medica 57, 169-176, 2019
202019
Assessment of chronic exposure effects and radioadaptive response of natural occurring radioactive materials (NORM)
SM El-Marakby, MM Awad, KM Eraba, MH Abdelgawad, OS Desouky
Radiation Physics and Chemistry 166, 108502, 2020
92020
Measurements of radiotherapy dosimetric parameters using Fricke gel dosimeter
MH Abdelgawad, YS Soliman, MI ElGohry, AA Eldib, CMC Ma, ...
Biomedical Physics & Engineering Express 3 (2), 025021, 2017
92017
Correlation of texture feature analysis with bone marrow infiltration in initial staging of patients with lymphoma using 18F-fluorodeoxyglucose positron emission tomography …
MA Kenawy, MM Khalil, MH Abdelgawad, HH El-Bahnasawy
Polish Journal of Radiology 85 (1), 586-594, 2020
72020
Dosimetric evaluation of the capabilities of two clinical treatment planning systems for prostate cancer
A Eldib, D Zhang, MH Abdelgawad, M Hossain, CMC Ma
Radiation Physics and Chemistry 188, 109642, 2021
42021
Investigating a correlation between MLC positional errors and IMRT QA passing rate
AE Yousif, MH Abdelgawad, AA Eldib, SM El-Sayed, MS Talaat
Radiation Physics and Chemistry 209, 111001, 2023
32023
DNA damage detection after chronic exposure and radio-adaptive response of naturally occurring radioactive materials (NORM)
SM El-Marakby, MH Abdelgawad, KM Eraba, OS Desouky
Arab Journal of Nuclear Sciences and Applications 54 (3), 34-45, 2021
32021
Study of the effects of naturally occurring radioactive materials on blood indices in blood’s rats
MH Abdelgawad, M Awd, KM Tohamy
Egyptian Journal of Biomedical Engineering and Biophysics 20 (1), 1-7, 2019
32019
Evaluation of thermal neutron dose from Am-Be source using gelatinized boron fricke dosimeter
E Aboelezz, MH Abdelgawad, SA Eman, GM Hassan
Radiation Physics and Chemistry 162, 131-135, 2019
22019
EPR dosimetric studies on strontium sulfate rods for possible use in radiotherapy
RA Fahim, YS Soliman, WB Beshir, MH Abdelgawad, AA Abdel-Fattah, ...
Materials Chemistry and Physics 275, 125255, 2022
12022
Dosimetric evaluation of a rotating gamma-ray system for stereotactic body radiation therapy
A Eldib, M Fareed, S Weiss, S Hayes, B Nguyen, G Mora, J Li, O Chibani, ...
Journal of Radiation Oncology 9, 173-184, 2020
12020
Preparation and Characterization of Frick gel dosimeter
MI El Gohary, YS Shabban, EA Amin, MHA Gawad, OS Desouky
1
Dosimetric evaluation of the capabilities of two clinical treatment planning systems for prostate cancerDosimetric evaluation of the capabilities of two clinical treatment …
AHAM CharlieMaa
Radiation physics and chemistry 188, 2021
2021
The Role of Texture Analysis and Radiomics in Prediction of Bone Marrow Infiltration in Patients with Lymphoma
MA Kenawy, M Khalil, MH Abdelgawad, HH El-Bahnasawy
Egyptian Journal of Biomedical Engineering and Biophysics 21 (1), 43-55, 2020
2020
Evaluation of a Treatment Planning System for CyberMat Beam Delivery
A Eldib, L Chen, J Fan, T Giaddui, M Abdelgawad, C Ma
MEDICAL PHYSICS 45 (6), E304-E304, 2018
2018
Investigating Beneficial Capabilities Achievable by a Rotating Gamma Ray System in Stereotactic Body Radiation Therapy
A Eldib, M Fareed, J Fan, J Li, L Chen, M Sherif, MA Gawad, C Ma
MEDICAL PHYSICS 44 (6), 2971-2971, 2017
2017
Investigation of a Novel Radiochromic Film Material for Radiotherapy Applications
MA Gawad, A Eldib, S Lotfy, O Desouky
MEDICAL PHYSICS 44 (6), 2934-2934, 2017
2017
Exploring the Dosimetric Advantage of a Novel Rotating Gamma Machine Equipped with Both MLC and Multiple Cone Colimators
A Eldib, I Veltchev, T Lin, R Price, G Mora, MA Gawad, M Sherif, C Ma
MEDICAL PHYSICS 44 (6), 2971-2972, 2017
2017
系统目前无法执行此操作,请稍后再试。