关注
Humberto R Gamba
Humberto R Gamba
在 utfpr.edu.br 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Using dynamic pupillometry as a simple screening tool to detect autonomic neuropathy in patients with diabetes: a pilot study
GL Ferrari, JLB Marques, RA Gandhi, SR Heller, FK Schneider, S Tesfaye, ...
Biomedical engineering online 9, 1-16, 2010
1112010
Multiple testing correction over contrasts for brain imaging
BAV Alberton, TE Nichols, HR Gamba, AM Winkler
NeuroImage 216, 116760, 2020
812020
Interaction of brain areas of visual and vestibular simultaneous activity with fMRI
HM Della-Justina, HR Gamba, K Lukasova, MP Nucci-da-Silva, ...
Experimental brain research 233, 237-252, 2015
742015
The influence of inspiratory muscle training combined with the Pilates method on lung function in elderly women: A randomized controlled trial
GM Alvarenga, SA Charkovski, LK Santos, MAB Silva, GO Tomaz, ...
Clinics 73, e356, 2018
732018
Measurement of electrical current density distribution within the tissues of the head by magnetic resonance imaging
HR Gamba, DT Delpy
Medical and Biological Engineering and Computing 36, 165-170, 1998
601998
Using visual attention to extract regions of interest in the context of image retrieval
O Marques, LM Mayron, GB Borba, HR Gamba
Proceedings of the 44th annual Southeast regional conference, 638-643, 2006
592006
An attention-driven model for grouping similar images with image retrieval applications
O Marques, LM Mayron, GB Borba, HR Gamba
EURASIP Journal on Advances in Signal Processing 2007, 1-17, 2006
482006
A computer tool for the fusion and visualization of thermal and magnetic resonance images
GL Bichinho, MA Gariba, IJ Sanches, HR Gamba, FPF Cruz, P Nohama
Journal of Digital Imaging 22, 527-534, 2009
462009
An approach to the assessment of diabetic neuropathy based on dynamic pupillometry
GL Ferrari, JLB Marques, RA Gandhi, CJ Emery, S Tesfaye, SR Heller, ...
2007 29th Annual International Conference of the IEEE Engineering in …, 2007
422007
Fusão 3D de imagens de MRI/CT e termografia
IJ Sanches, HR Gamba, MA Souza, EB Neves, P Nohama
Revista Brasileira de Engenharia Biomédica 29, 298-308, 2013
342013
Measurement of electrical current density distribution in a simple head phantom with magnetic resonance imaging
HR Gamba, R Bayford, D Holder
Physics in Medicine & Biology 44 (1), 281, 1999
311999
Pulmonary crackle characterization: approaches in the use of discrete wavelet transform regarding border effect, mother-wavelet selection, and subband reduction
VI Quandt, ER Pacola, SF Pichorim, HR Gamba, MA Sovierzoski
Research on Biomedical Engineering 31 (2), 148-159, 2015
252015
Physiotherapy intervention during level I of pulmonary rehabilitation on chronic obstructive pulmonary disease: a systematic review
GM de Alvarenga, HR Gamba, LE Hellman, VG Ferrari, RM de Macedo
The open respiratory medicine journal 10, 12, 2016
212016
Bone mineral content of the third metacarpal bone in quarter horse foals from birth to one year of age
P Reichmann, A Moure, HR Gamba
Journal of Equine Veterinary Science 24 (9), 391-396, 2004
182004
Sistema automático para contagem de colônias em placas de Petri
J Osowsky, HR Gamba
Revista Brasileira de Engenharia Biomédica 17 (3), 131-139, 2001
172001
Galvanic vestibular stimulator for fMRI studies
HM Della-Justina, T Manczak, AM Winkler, DB Araújo, MA Souza, ...
Revista Brasileira de Engenharia Biomédica 30, 70-82, 2014
142014
An unsupervised method for clustering images based on their salient regions of interest
GB Borba, HR Gamba, O Marques, LM Mayron
Proceedings of the 14th ACM international conference on Multimedia, 145-148, 2006
142006
Development and evaluation of a customized wrist-hand orthosis using 3D technology for a child with cerebral palsy-a case study
C Schmitz, YT Mori, HR Gamba, P Nohama, MA de Souza
2019 41st annual international conference of the IEEE engineering in …, 2019
132019
Pupil and iris detection in dynamic pupillometry using the OpenCV library
L Schwarz, HR Gamba, F Pacheco, RB Ramos, MA Sovierzoski
2012 5th International Congress on Image and Signal Processing, 211-215, 2012
132012
In vivo assessment of the impedance ratio method used in electronic foramen locators
MVH Rambo, HR Gamba, GB Borba, JM Maia, CAS Ramos
Biomedical engineering online 9, 1-12, 2010
132010
系统目前无法执行此操作,请稍后再试。
文章 1–20