Stray current control in DC mass transit systems I Cotton, C Charalambous, P Aylott, P Ernst IEEE Transactions on vehicular technology 54 (2), 722-730, 2005 | 212 | 2005 |
Dissolved gas analysis of alternative fluids for power transformers Z Wang, I Cotton, S Northcote IEEE Electrical Insulation Magazine 23 (5), 5-14, 2007 | 163 | 2007 |
Reliability impact of dynamic thermal rating system in wind power integrated network J Teh, I Cotton IEEE Transactions on Reliability 65 (2), 1081-1089, 2015 | 157 | 2015 |
Lightning protection for wind turbine blades and bearings I Cotton, N Jenkins, K Pandiaraj Wind Energy: An International Journal for Progress and Applications in Wind …, 2001 | 150 | 2001 |
Partial discharge control in a power electronic module using high permittivity non-linear dielectrics N Wang, I Cotton, J Robertson, S Follmann, K Evans, D Newcombe IEEE Transactions on Dielectrics and Electrical Insulation 17 (4), 1319-1326, 2010 | 132 | 2010 |
Higher voltage aircraft power systems I Cotton, A Nelms, M Husband IEEE Aerospace and Electronic Systems Magazine 23 (2), 25-32, 2008 | 109 | 2008 |
Choice of optimal voltage for more electric aircraft wiring systems I Christou, A Nelms, I Cotton, M Husband IET Electrical Systems in Transportation 1 (1), 24-30, 2011 | 82 | 2011 |
Critical span identification model for dynamic thermal rating system placement J Teh, I Cotton IET Generation, Transmission & Distribution 9 (16), 2644-2652, 2015 | 76 | 2015 |
Impact of low pressure aerospace environment on machine winding insulation R Rui, I Cotton 2010 IEEE International Symposium on Electrical Insulation, 1-5, 2010 | 70 | 2010 |
A simulation tool to predict the impact of soil topologies on coupling between a light rail system and buried third-party infrastructure CA Charalambous, I Cotton, P Aylott IEEE Transactions on Vehicular Technology 57 (3), 1404-1416, 2008 | 67 | 2008 |
Influence of soil structures on corrosion performance of floating-DC transit systems C Charalambous, I Cotton IET Electric Power Applications 1 (1), 9-16, 2007 | 64 | 2007 |
Induced voltages on long aerial and buried pipelines due to transmission line transients K Kopsidas, I Cotton IEEE Transactions on Power Delivery 23 (3), 1535-1543, 2008 | 60 | 2008 |
A holistic stray current assessment of bored tunnel sections of DC transit systems CA Charalambous, I Cotton, P Aylott, ND Kokkinos IEEE Transactions on Power Delivery 28 (2), 1048-1056, 2012 | 55 | 2012 |
Lightning protection of wind turbines–a comparison of measured data with required protection levels V Peesapati, I Cotton, T Sorensen, T Krogh, N Kokkinos IET renewable power generation 5 (1), 48-57, 2011 | 54 | 2011 |
Modeling for preliminary stray current design assessments: The effect of crosstrack regeneration supply CA Charalambous, I Cotton, P Aylott IEEE transactions on power delivery 28 (3), 1899-1908, 2013 | 50 | 2013 |
Risk informed design modification of dynamic thermal rating system J Teh, I Cotton IET Generation, Transmission & Distribution 9 (16), 2697-2704, 2015 | 48 | 2015 |
The update of IEC 61400-24 lightning protection of wind turbines TS Sorensen, JA Plumer, J Montanyà, TH Krogh, B Hermoso, J Birkl, ... 29th International Conference on Lightning Protection, 23rd–26th June, Sweden, 2008 | 46 | 2008 |
Comparison of transient and power frequency-induced voltages on a pipeline parallel to an overhead transmission line I Cotton, K Kopsidas, Y Zhang IEEE transactions on power delivery 22 (3), 1706-1714, 2007 | 44 | 2007 |
Lightning protection of wind turbines—A comparison of real lightning strike data and finite element lightning attachment analysis V Peesapati, I Cotton 2009 International Conference on Sustainable Power Generation and Supply, 1-8, 2009 | 41 | 2009 |
Windfarm earthing I Cotton, N Jenkins 1999 European Wind Energy Conference, 725-728, 2014 | 40 | 2014 |