An electronic nose based on solid state sensor arrays for low-cost indoor air quality monitoring applications S Zampolli, I Elmi, F Ahmed, M Passini, GC Cardinali, S Nicoletti, L Dori Sensors and Actuators B: Chemical 101 (1-2), 39-46, 2004 | 291 | 2004 |
Real-time monitoring of sub-ppb concentrations of aromatic volatiles with a MEMS-enabled miniaturized gas-chromatograph S Zampolli, I Elmi, F Mancarella, P Betti, E Dalcanale, GC Cardinali, ... Sensors and Actuators B: Chemical 141 (1), 322-328, 2009 | 255 | 2009 |
Flexible tag microlab development: gas sensors integration in RFID flexible tags for food logistic E Abad, S Zampolli, S Marco, A Scorzoni, B Mazzolai, A Juarros, ... Sensors and Actuators B: Chemical 127 (1), 2-7, 2007 | 201 | 2007 |
Development of ultra-low-power consumption MOX sensors with ppb-level VOC detection capabilities for emerging applications I Elmi, S Zampolli, E Cozzani, F Mancarella, GC Cardinali Sensors and Actuators B: Chemical 135 (1), 342-351, 2008 | 189 | 2008 |
Selectivity enhancement of metal oxide gas sensors using a micromachined gas chromatographic column S Zampolli, I Elmi, J Stürmann, S Nicoletti, L Dori, GC Cardinali Sensors and Actuators B: Chemical 105 (2), 400-406, 2005 | 174 | 2005 |
On the potential of ion mobility spectrometry coupled to GC pre-separation–A tutorial W Vautz, J Franzke, S Zampolli, I Elmi, S Liedtke Analytica chimica acta 1024, 52-64, 2018 | 89 | 2018 |
Ultra-low-power components for an RFID Tag with physical and chemical sensors S Zampolli, I Elmi, E Cozzani, GC Cardinali, A Scorzoni, M Cicioni, ... Microsystem technologies 14, 581-588, 2008 | 69 | 2008 |
Environmental monitoring system compliant with the IEEE 1451 standard and featuring a simplified transducer interface L Bissi, P Placidi, A Scorzoni, I Elmi, S Zampolli Sensors and Actuators A: Physical 137 (1), 175-184, 2007 | 49 | 2007 |
Use of different sensing materials and deposition techniques for thin-film sensors to increase sensitivity and selectivity S Nicoletti, S Zampolli, I Elmi, L Dori, M Severi IEEE Sensors Journal 3 (4), 454-459, 2003 | 48 | 2003 |
A supramolecular approach to sub-ppb aromatic VOC detection in air S Zampolli, P Betti, I Elmi, E Dalcanale Chemical communications, 2790-2792, 2007 | 43 | 2007 |
In search of the ultimate benzene sensor: the EtQxBox solution JW Trzcinski, R Pinalli, N Riboni, A Pedrini, F Bianchi, S Zampolli, I Elmi, ... ACS sensors 2 (4), 590-598, 2017 | 39 | 2017 |
Compact-GC platform: A flexible system integration strategy for a completely microsystems-based gas-chromatograph S Zampolli, I Elmi, GC Cardinali, L Masini, F Bonafè, F Zardi Sensors and Actuators B: Chemical 305, 127444, 2020 | 38 | 2020 |
A programmable interface circuit for an ultralow power gas sensor L Bissi, M Cicioni, P Placidi, S Zampolli, I Elmi, A Scorzoni IEEE Transactions on Instrumentation and Measurement 60 (1), 282-289, 2010 | 34 | 2010 |
Drop-coated sensing layers on ultra low power hotplates for an RFID flexible tag microlab E Espinosa, R Ionescu, S Zampolli, I Elmi, GC Cardinali, E Abad, ... Sensors and Actuators B: Chemical 144 (2), 462-466, 2010 | 34 | 2010 |
Discontinuously operated metal oxide gas sensors for flexible tag microlab applications I Sayhan, A Helwig, T Becker, G Muller, I Elmi, S Zampolli, M Padilla, ... IEEE Sensors Journal 8 (2), 176-181, 2008 | 34 | 2008 |
Thermal conductivity detector for gas chromatography: Very wide gain range acquisition system and experimental measurements F Rastrello, P Placidi, A Scorzoni, E Cozzani, M Messina, I Elmi, ... IEEE Transactions on Instrumentation and Measurement 62 (5), 974-981, 2013 | 31 | 2013 |
Development of ultra low power consumption hotplates for gas sensing applications I Elmi, S Zampolli, E Cozzani, M Passini, GC Cardinali, M Severi SENSORS, 2006 IEEE, 243-246, 2006 | 30 | 2006 |
Conventional and enantioselective gas chromatography with microfabricated planar columns for analysis of real-world samples of plant volatile fraction C Cagliero, S Galli, M Galli, I Elmi, M Belluce, S Zampolli, B Sgorbini, ... Journal of Chromatography A 1429, 329-339, 2016 | 29 | 2016 |
Rapid screening and identification of illicit drugs by IR absorption spectroscopy and gas chromatography S Mengali, N Liberatore, D Luciani, R Viola, GC Cardinali, I Elmi, A Poggi, ... Quantum Sensing and Nanophotonic Devices X 8631, 489-498, 2013 | 24 | 2013 |
Adaptive K-NN for the detection of air pollutants with a sensor array A Roncaglia, I Elmi, L Dori, M Rudan IEEE Sensors Journal 4 (2), 248-256, 2004 | 23 | 2004 |