Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning IJ Chetty, B Curran, JE Cygler, JJ DeMarco, G Ezzell, BA Faddegon, ... Medical physics 34 (12), 4818-4853, 2007 | 881 | 2007 |
Commissioning and quality assurance of treatment planning computers J Van Dyk, RB Barnett, JE Cygler, PC Shragge International Journal of Radiation Oncology* Biology* Physics 26 (2), 261-273, 1993 | 824 | 1993 |
Evaluation of a dual bias dual metal oxide‐silicon semiconductor field effect transistor detector as radiation dosimeter M Soubra, J Cygler, G Mackay Medical physics 21 (4), 567-572, 1994 | 335 | 1994 |
GafChromic MD‐55: Investigated as a precision dosimeter NV Klassen, L Van Der Zwan, J Cygler Medical Physics 24 (12), 1924-1934, 1997 | 246 | 1997 |
In vivo dosimetry in brachytherapy K Tanderup, S Beddar, CE Andersen, G Kertzscher, JE Cygler Medical physics 40 (7), 070902, 2013 | 213 | 2013 |
Radiotherapy dosimetry using a commercial OSL system A Viamonte, LAR Da Rosa, LA Buckley, A Cherpak, JE Cygler Medical physics 35 (4), 1261-1266, 2008 | 195 | 2008 |
AAPM TG 191: Clinical use of luminescent dosimeters: TLDs and OSLDs SF Kry, P Alvarez, JE Cygler, LA DeWerd, RM Howell, S Meeks, ... Medical physics 47 (2), e19-e51, 2020 | 179 | 2020 |
Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning JE Cygler, GM Daskalov, GH Chan, GX Ding Medical physics 31 (1), 142-153, 2004 | 153 | 2004 |
A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm GX Ding, JE Cygler, WY Christine, NI Kalach, G Daskalov International Journal of Radiation Oncology* Biology* Physics 63 (2), 622-633, 2005 | 110 | 2005 |
Electron dose distributions in experimental phantoms: a comparison with 2D pencil beam calculations J Cygler, JJ Battista, JW Scrimger, E Mah, J Antolak Physics in Medicine & Biology 32 (9), 1073, 1987 | 107 | 1987 |
In vivo dosimetry: trends and prospects for brachytherapy G Kertzscher, A Rosenfeld, S Beddar, K Tanderup, JE Cygler The British journal of radiology 87 (1041), 20140206, 2014 | 102 | 2014 |
Monte Carlo investigation of electron beam output factors versus size of square cutout GG Zhang, DWO Rogers, JE Cygler, TR Mackie Medical physics 26 (5), 743-750, 1999 | 94 | 1999 |
First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning—new issues for clinical consideration GX Ding, DM Duggan, CW Coffey, P Shokrani, JE Cygler Physics in Medicine & Biology 51 (11), 2781, 2006 | 82 | 2006 |
Two-stage cell shrinkage and the OER for radiation-induced apoptosis of rat thymocytes NV Klassen, PR Walker, CK Ross, J Cygler, B Lach International journal of radiation biology 64 (5), 571-581, 1993 | 81 | 1993 |
The effect of dose rate dependence of p‐type silicon detectors on linac relative dosimetry D Wilkins, XA Li, J Cygler, L Gerig Medical physics 24 (6), 879-881, 1997 | 75 | 1997 |
Clinical use of a commercial Monte Carlo treatment planning system for electron beams JE Cygler, C Lochrin, GM Daskalov, M Howard, R Zohr, B Esche, L Eapen, ... Physics in Medicine & Biology 50 (5), 1029, 2005 | 67 | 2005 |
Penile brachytherapy: technical aspects and postimplant issues J Crook, J Jezioranski, JE Cygler Brachytherapy 9 (2), 151-158, 2010 | 63 | 2010 |
Feasibility study of using MOSFET detectors for in vivo dosimetry during permanent low-dose-rate prostate implants JE Cygler, A Saoudi, G Perry, C Morash, E Choan Radiotherapy and oncology 80 (3), 296-301, 2006 | 61 | 2006 |
Clinical dosimetry measurements in radiotherapy DWO Rogers, JE Cygler (No Title), 2009 | 60 | 2009 |
Correlating the degree of needle trauma during prostate brachytherapy and the development of acute urinary toxicity L Eapen, C Kayser, Y Deshaies, G Perry, E Choan, C Morash, JE Cygler, ... International Journal of Radiation Oncology* Biology* Physics 59 (5), 1392-1394, 2004 | 60 | 2004 |