Magnetic resonance imaging: physical principles and sequence design RW Brown, YCN Cheng, EM Haacke, MR Thompson, R Venkatesan John Wiley & Sons, 2014 | 5532 | 2014 |
Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent. JR Reichenbach, R Venkatesan, DJ Schillinger, DK Kido, EM Haacke Radiology 204 (1), 272-277, 1997 | 815 | 1997 |
Theory and application of static field inhomogeneity effects in gradient‐echo imaging JR Reichenbach, R Venkatesan, DA Yablonskiy, MR Thompson, S Lai, ... Journal of Magnetic Resonance Imaging 7 (2), 266-279, 1997 | 363 | 1997 |
Accurate determination of spin‐density and T1 in the presence of RF‐field inhomogeneities and flip‐angle miscalibration R Venkatesan, W Lin, EM Haacke Magnetic resonance in medicine 40 (4), 592-602, 1998 | 188 | 1998 |
Evaluation of polymer gels and MRI as a 3‐D dosimeter for intensity‐modulated radiation therapy DA Low, JF Dempsey, R Venkatesan, S Mutic, J Markman, EM Haacke, ... Medical physics 26 (8), 1542-1551, 1999 | 167 | 1999 |
Compressed sensing MRI: a review S Geethanath, R Reddy, AS Konar, S Imam, R Sundaresan, RB DR, ... Critical Reviews™ in Biomedical Engineering 41 (3), 2013 | 152 | 2013 |
Detection of BOLD changes by means of a frequency‐sensitive trueFISP technique: preliminary results K Scheffler, E Seifritz, D Bilecen, R Venkatesan, J Hennig, M Deimling, ... NMR in Biomedicine: An International Journal Devoted to the Development and …, 2001 | 125 | 2001 |
High-resolution, multiple gradient-echo functional MRI at 1.5 T M Barth, JR Reichenbach, R Venkatesan, E Moser, EM Haacke Magnetic resonance imaging 17 (3), 321-329, 1999 | 80 | 1999 |
Absolute measurements of water content using magnetic resonance imaging: preliminary findings in an in vivo focal ischemic rat model R Venkatesan, W Lin, K Gurleyik, YY He, RP Paczynski, WJ Powers, ... Magnetic Resonance in Medicine: An Official Journal of the International …, 2000 | 77 | 2000 |
An absolute measurement of brain water content using magnetic resonance imaging in two focal cerebral ischemic rat models W Lin, R Venkatesan, K Gurleyik, YY He, WJ Powers, CY Hsu Journal of Cerebral Blood Flow & Metabolism 20 (1), 37-44, 2000 | 60 | 2000 |
Effects of fluid management on edema volume and midline shift in a rat model of ischemic stroke RP Paczynski, R Venkatesan, MN Diringer, YY He, CY Hsu, W Lin Stroke 31 (7), 1702-1708, 2000 | 50 | 2000 |
Quantitative regional brain water measurement with magnetic resonance imaging in a focal ischemia model W Lin, RP Paczynski, R Venkatesan, YY He, WJ Powers, CY Hsu, ... Magnetic resonance in medicine 38 (2), 303-310, 1997 | 45 | 1997 |
Role of high resolution in magnetic resonance (MR) imaging: Applications to MR angiography, intracranial T1‐weighted imaging, and image interpolation R Venkatesan, EM Haacke International journal of imaging systems and technology 8 (6), 529-543, 1997 | 45 | 1997 |
Magnetic resonance imaging of the brain with gadopentetate dimeglumine‐DTPA: Comparison of T1‐weighted spin‐echo and 3D gradient‐echo sequences D Li, EM Haacke, RW Tarr, R Venkatesan, W Lin, P Wielopolski Journal of Magnetic Resonance Imaging 6 (3), 415-424, 1996 | 45 | 1996 |
Pulseq-Graphical Programming Interface: Open source visual environment for prototyping pulse sequences and integrated magnetic resonance imaging algorithm development KS Ravi, S Potdar, P Poojar, AK Reddy, S Kroboth, JF Nielsen, M Zaitsev, ... Magnetic resonance imaging 52, 9-15, 2018 | 42 | 2018 |
Signal, contrast and noise EM Haacke, RW Brown, MR Thompson, R Venkatesan Magnetic resonance imaging: physical principles and sequence design, 331-380, 1999 | 42 | 1999 |
Accuracy of T1 measurements at high temporal resolution: feasibility of dynamic measurement of blood T1 after contrast administration J Zheng, R Venkatesan, EM Haacke, FM Cavagna, PJ Finn, D Li Journal of Magnetic Resonance Imaging 10 (4), 576-581, 1999 | 36 | 1999 |
Noise in polymer gel measurements using MRI DA Low, J Markman, JF Dempsey, S Mutic, M Oldham, R Venkatesan, ... Medical physics 27 (8), 1814-1817, 2000 | 32 | 2000 |
Correlation of phase values with CT Hounsfield and R2* values in calcified neurocysticercosis B Roy, S Verma, R Awasthi, RK Rathore, R Venkatesan, SA Yoganathan, ... Journal of Magnetic Resonance Imaging 34 (5), 1060-1064, 2011 | 23 | 2011 |
Method and apparatus for generating T2* weighted magnetic resonance images R Bhardwaj, AT Vu, R Venkatesan US Patent 7,800,367, 2010 | 20 | 2010 |