Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic‐on‐ceramic total hip replacement M Al‐Hajjar, IJ Leslie, J Tipper, S Williams, J Fisher, LM Jennings Journal of Biomedical Materials Research Part B: Applied Biomaterials 95 (2 …, 2010 | 103 | 2010 |
Wear of 36-mm BIOLOX® delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions M Al-Hajjar, J Fisher, JL Tipper, S Williams, LM Jennings Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2013 | 95 | 2013 |
Wear of novel ceramic‐on‐ceramic bearings under adverse and clinically relevant hip simulator conditions M Al‐Hajjar, LM Jennings, S Begand, T Oberbach, D Delfosse, J Fisher Journal of Biomedical Materials Research Part B: Applied Biomaterials 101 (8 …, 2013 | 69 | 2013 |
Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge‐loading conditions M Al‐Hajjar, J Fisher, S Williams, JL Tipper, LM Jennings Journal of Biomedical Materials Research Part B: Applied Biomaterials 101 (2 …, 2013 | 59 | 2013 |
Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings M Ali, M Al-Hajjar, S Partridge, S Williams, J Fisher, LM Jennings Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2016 | 35 | 2016 |
Comparison of ceramic‐on‐metal and metal‐on‐metal hip prostheses under adverse conditions S Williams, M Al‐Hajjar, GH Isaac, J Fisher Journal of Biomedical Materials Research Part B: Applied Biomaterials 101 (5 …, 2013 | 35 | 2013 |
(iv) Enhancing the safety and reliability of joint replacement implants LM Jennings, M Al-Hajjar, CL Brockett, S Williams, JL Tipper, E Ingham, ... Orthopaedics and trauma 26 (4), 246-252, 2012 | 29 | 2012 |
An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements O O'Dwyer Lancaster‐Jones, S Williams, LM Jennings, J Thompson, ... Journal of Biomedical Materials Research Part B: Applied Biomaterials 106 (5 …, 2018 | 28 | 2018 |
Experimental validation of finite element modelling of a modular metal-on-polyethylene total hip replacement X Hua, L Wang, M Al-Hajjar, Z Jin, RK Wilcox, J Fisher Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2014 | 28 | 2014 |
Wear of composite ceramics in mixed‐material combinations in total hip replacement under adverse edge loading conditions M Al‐Hajjar, S Carbone, LM Jennings, S Begand, T Oberbach, D Delfosse, ... Journal of Biomedical Materials Research Part B: Applied Biomaterials 105 (6 …, 2017 | 27 | 2017 |
Evaluation of a new methodology to simulate damage and wear of polyethylene hip replacements subjected to edge loading in hip simulator testing S Partridge, JL Tipper, M Al‐Hajjar, GH Isaac, J Fisher, S Williams Journal of Biomedical Materials Research Part B: Applied Biomaterials 106 (4 …, 2018 | 20 | 2018 |
In vitro measurement of wear in joint replacements: a stratified approach for enhanced reliability “SAFER” pre-clinical simulation testing J Fisher, M Al-Hajjar, S Williams, LM Jennings, E Ingham Seminars in arthroplasty 23 (4), 286-288, 2012 | 13 | 2012 |
Combined wear and ageing of ceramic-on-ceramic bearings in total hip replacement under edge loading conditions M Al-Hajjar, L Gremillard, S Begand, T Oberbach, K Hans, D Delfosse, ... Journal of the mechanical behavior of biomedical materials 98, 40-47, 2019 | 12 | 2019 |
An investigation into the hydrodynamic analysis of vessels with a zero or forward speed SX Du, DA Hudson, WG Price, P Temarel Proceedings of the Institution of Mechanical Engineers, Part M: Journal of …, 2012 | 11 | 2012 |
(v) Simulation and measurement of wear in metal-on-metal bearings in vitro-understanding the reasons for increased wear J Fisher, M Al Hajjar, S Williams, J Tipper, E Ingham, L Jennings Orthopaedics and Trauma 26 (4), 253-258, 2012 | 10 | 2012 |
Impingement in total hip arthroplasty: a geometric model GM Pryce, B Sabu, M Al-Hajjar, RK Wilcox, J Thompson, GH Isaac, ... Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2022 | 8 | 2022 |
Dynamic virtual simulation of the occurrence and severity of edge loading in hip replacements associated with variation in the rotational and translational surgical position J Leng, M Al-Hajjar, R Wilcox, A Jones, D Barton, J Fisher Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2017 | 8 | 2017 |
Wear of hard-on-hard hip prostheses: influence of head size, surgical position, material and function M Al-Hajjar University of Leeds, 2012 | 7 | 2012 |
Computationally efficient modelling of hip replacement separation due to small mismatches in component centres of rotation L Etchels, L Wang, M Al-Hajjar, S Williams, J Thompson, G Isaac, ... Journal of Biomechanics 95, 109296, 2019 | 6 | 2019 |
Wear and deformation of metal-on-polyethylene hip replacements under edge loading conditions due to variations in surgical positioning M Ali, M Al-Hajjar, LM Jennings, J Fisher Orthopaedic Proceedings 99 (SUPP_3), 12-12, 2017 | 5 | 2017 |