PET/MR imaging of bone lesions–implications for PET quantification from imperfect attenuation correction A Samarin, C Burger, SD Wollenweber, DW Crook, IA Burger, DT Schmid, ... European journal of nuclear medicine and molecular imaging 39, 1154-1160, 2012 | 263 | 2012 |
Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET S Ahn, SG Ross, E Asma, J Miao, X Jin, L Cheng, SD Wollenweber, ... Physics in Medicine & Biology 60 (15), 5733, 2015 | 152 | 2015 |
Quiescent period respiratory gating for PET/CT C Liu, A Alessio, L Pierce, K Thielemans, S Wollenweber, A Ganin, ... Medical physics 37 (9), 5037-5043, 2010 | 133 | 2010 |
Comparison of 4-class and continuous fat/water methods for whole-body, MR-based PET attenuation correction SD Wollenweber, S Ambwani, AHR Lonn, DD Shanbhag, ... IEEE Transactions on Nuclear Science 60 (5), 3391-3398, 2013 | 114 | 2013 |
Evaluation of an atlas-based PET head attenuation correction using PET/CT & MR patient data SD Wollenweber, S Ambwani, G Delso, AHR Lonn, R Mullick, F Wiesinger, ... IEEE Transactions on Nuclear Science 60 (5), 3383-3390, 2013 | 104 | 2013 |
Comparison of Hotelling observer models and human observers in defect detection from myocardial SPECT imaging SD Wollenweber, BMW Tsui, DS Lalush, EC Frey, KJ LaCroix, ... IEEE Transactions on Nuclear Science 46 (6), 2098-2103, 1999 | 100 | 1999 |
Methods for automatic protocol selection SD Wollenweber, CW Stearns, DM Miesbauer US Patent 7,542,792, 2009 | 70 | 2009 |
Parameterization of a model-based 3-D PET scatter correction SD Wollenweber IEEE Transactions on Nuclear Science 49 (3), 722-727, 2002 | 66 | 2002 |
Methods and systems for assessing patient movement in diagnostic imaging SD Wollenweber US Patent 8,107,695, 2012 | 65 | 2012 |
The QIBA profile for FDG PET/CT as an imaging biomarker measuring response to cancer therapy PE Kinahan, ES Perlman, JJ Sunderland, R Subramaniam, ... Radiology 294 (3), 647-657, 2020 | 58 | 2020 |
Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET/CT studies BR Sah, P Stolzmann, G Delso, SD Wollenweber, M Hüllner, YA Hakami, ... Nuclear medicine communications 38 (1), 57-66, 2017 | 54 | 2017 |
Motion compensation in image processing G Gopalakrishnan, A Ganin, RM Majeshwar, KFJJ Thielemans, ... US Patent 9,129,426, 2015 | 54 | 2015 |
Image enhancement of whole-body oncology [18F]-FDG PET scans using deep neural networks to reduce noise A Mehranian, SD Wollenweber, MD Walker, KM Bradley, PA Fielding, ... European journal of nuclear medicine and molecular imaging 49 (2), 539-549, 2022 | 46 | 2022 |
Systems and methods for correcting a positron emission tomography emission image SD Wollenweber, A Ganin US Patent 7,507,968, 2009 | 46 | 2009 |
Measured count-rate performance of the Discovery STE PET/CT scanner in 2D, 3D and partial collimation acquisition modes LR MacDonald, RE Schmitz, AM Alessio, SD Wollenweber, CW Stearns, ... Physics in Medicine & Biology 53 (14), 3723, 2008 | 46 | 2008 |
Comparison of different methods for data-driven respiratory gating of PET data K Thielemans, P Schleyer, PK Marsden, RM Manjeshwar, ... 2013 IEEE nuclear science symposium and medical imaging conference (2013 NSS …, 2013 | 44 | 2013 |
Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT MA Queiroz, G Delso, S Wollenweber, T Deller, K Zeimpekis, M Huellner, ... PLoS One 10 (7), e0128842, 2015 | 43 | 2015 |
Evaluation of lesion detectability in positron emission tomography when using a convergent penalized likelihood image reconstruction method KA Wangerin, S Ahn, S Wollenweber, SG Ross, PE Kinahan, ... Journal of Medical Imaging 4 (1), 011002-011002, 2017 | 38 | 2017 |
System and method for generating PET-CT images V Shanmugam, MM Hussaini, SD Wollenweber, MG Bonner US Patent 7,447,345, 2008 | 38 | 2008 |
System and method for table/gantry alignment in imaging systems SD Wollenweber US Patent 6,917,666, 2005 | 34 | 2005 |