Lipid uptake and skin occlusion following topical application of oils on adult and infant skin GN Stamatas, J de Sterke, M Hauser, O von Stetten, A van der Pol Journal of Dermatological Science 50 (2), 135-142, 2008 | 175 | 2008 |
Studying the effectiveness of penetration enhancers to deliver retinol through the stratum cornum by in vivo confocal Raman spectroscopy M Mélot, PDA Pudney, AM Williamson, PJ Caspers, A Van Der Pol, ... Journal of controlled release 138 (1), 32-39, 2009 | 168 | 2009 |
An In Vivo Confocal Raman Study of the Delivery of Trans Retinol to the Skin PDA Pudney, M Mélot, PJ Caspers, A Van Der Pol, GJ Puppels Applied Spectroscopy 61 (8), 804-811, 2007 | 164 | 2007 |
Pharmaceutical applications of Raman spectroscopy S Ekins John Wiley & Sons, 2007 | 162 | 2007 |
An ab initio intermolecular potential for the carbon monoxide dimer (CO) 2 A Van der Pol, A Van der Avoird, PES Wormer The Journal of Chemical Physics 92 (12), 7498-7504, 1990 | 133 | 1990 |
In vivo Raman spectroscopy detects increased epidermal antioxidative potential with topically applied carotenoids J Lademann, PJ Caspers, A Van Der Pol, H Richter, A Patzelt, L Zastrow, ... Laser Physics Letters 6 (1), 76-79, 2009 | 128 | 2009 |
In vivo distribution of carotenoids in different anatomical locations of human skin: comparative assessment with two different Raman spectroscopy methods ME Darvin, JW Fluhr, P Caspers, A Van Der Pool, H Richter, A Patzelt, ... Experimental dermatology 18 (12), 1060-1063, 2009 | 110 | 2009 |
Assessment of human stratum corneum thickness and its barrier properties by in‐vivo confocal Raman spectroscopy S Bielfeldt, V Schoder, U Ely, A Van Der Pol, J De Sterke, KP Wilhelm International Journal of Cosmetic Science 31 (6), 479-480, 2009 | 87 | 2009 |
Ordering of intercalated water and carbonate anions in hydrotalcite. An NMR study A Van der Pol, BL Mojet, E Van de Ven, E De Boer The Journal of Physical Chemistry 98 (15), 4050-4054, 1994 | 56 | 1994 |
The effect of material defects on the fatigue behaviour and the fracture strain of ABS R Marissen, D Schudy, A Kemp, SMH Coolen, WG Duijzings, ... Journal of materials science 36, 4167-4180, 2001 | 42 | 2001 |
Kinetics of carotenoid distribution in human skin in vivo after exogenous stress: disinfectant and wIRA-induced carotenoid depletion recovers from outside to inside JW Fluhr, P Caspers, JA van der Pol, H Richter, W Sterry, J Lademann, ... Journal of Biomedical Optics 16 (3), 035002-035002-7, 2011 | 38 | 2011 |
A study of the phase behaviour of polyethylene blends using micro-Raman imaging RL Morgan, MJ Hill, PJ Barham, A Van der Pol, BJ Kip, R Ottjes, ... Polymer 42 (5), 2121-2135, 2001 | 37 | 2001 |
On the use of recent developments in vibrational spectroscopic instrumentation in an industrial environment: quicker, smaller and more robust BJ Kip, T Berghmans, P Palmen, A van der Pol, M Huys, H Hartwig, ... Vibrational spectroscopy 24 (1), 75-92, 2000 | 30 | 2000 |
The electron paramagnetic resonance spectrum of Ag2+ 3 A Van Der Pol, EJ Reijersen, E De Boer, T Wasowicz, J Michalik Molecular Physics 75 (1), 37-42, 1992 | 30 | 1992 |
In vivo Monitoring of epidermal absorption of hazardous substances by confocal Raman micro‐spectroscopy HC Broding, A van der Pol, J de Sterke, C Monsé, M Fartasch, T Brüning JDDG: Journal der Deutschen Dermatologischen Gesellschaft 9 (8), 618-627, 2011 | 24 | 2011 |
Magnetic resonance studies on porous alumina doped with iron and chromium AÚ der Pol, PM Arno, GJMP ávan Moorsel, E Boer Journal of the Chemical Society, Faraday Transactions 91 (10), 1519-1522, 1995 | 23 | 1995 |
EPR and NMR studies of amorphous aluminium borates A der Pol, PM Arno, GJ ávan Moorsel, E Boer Journal of the Chemical Society, Faraday Transactions 90 (18), 2663-2670, 1994 | 21 | 1994 |
A combined Raman imaging and transmission electron microscopy study of blends of a deuterated linear polyethylene and a low-density polyethylene RL Morgan, MJ Hill, PJ Barham, A Van Der Pol, B Kip, J Van Ruiten, ... Journal of Macromolecular Science, Part B: Physics 38 (4), 419-437, 1999 | 16 | 1999 |
Paramagnetic silver species in irradiated Ag− NaA zeolites. An EPR and ESEEM study J Michalik, A Van der Pol, EJ Reijerse, T Wasowicz, E De Boer Applied Magnetic Resonance 3, 19-35, 1992 | 15 | 1992 |
14 Confocal Raman Spectroscopy for In Vivo Skin Hydration Measurement A van der Pol, PJ Caspers Cosmetic Science and Technology, 151, 2009 | 11* | 2009 |