A new design and rationale for 3D orthogonally oversampled k‐space trajectories JG Pipe, NR Zwart, EA Aboussouan, RK Robison, A Devaraj, KO Johnson Magnetic resonance in medicine 66 (5), 1303-1311, 2011 | 124 | 2011 |
Efficient sample density estimation by combining gridding and an optimized kernel NR Zwart, KO Johnson, JG Pipe Magnetic resonance in medicine 67 (3), 701-710, 2012 | 114 | 2012 |
Turboprop: improved PROPELLER imaging JG Pipe, N Zwart Magnetic Resonance in Medicine: An Official Journal of the International …, 2006 | 113 | 2006 |
ISMRM Raw data format: A proposed standard for MRI raw datasets SJ Inati, JD Naegele, NR Zwart, V Roopchansingh, MJ Lizak, DC Hansen, ... Magnetic resonance in medicine 77 (1), 411-421, 2017 | 112 | 2017 |
Spiral trajectory design: a flexible numerical algorithm and base analytical equations JG Pipe, NR Zwart Magnetic Resonance in Medicine 71 (1), 278-285, 2014 | 78 | 2014 |
Graphical programming interface: a development environment for MRI methods NR Zwart, JG Pipe Magnetic resonance in medicine 74 (5), 1449-1460, 2015 | 75 | 2015 |
Revised motion estimation algorithm for PROPELLER MRI JG Pipe, WN Gibbs, Z Li, JP Karis, M Schar, NR Zwart Magnetic resonance in medicine 72 (2), 430-437, 2014 | 54 | 2014 |
Joint water–fat separation and deblurring for spiral imaging D Wang, NR Zwart, JG Pipe Magnetic Resonance in Medicine 79 (6), 3218-3228, 2018 | 50 | 2018 |
Multidirectional high‐moment encoding in phase contrast MRI NR Zwart, JG Pipe Magnetic resonance in medicine 69 (6), 1553-1563, 2013 | 37 | 2013 |
Arterial spin labeled perfusion imaging using three‐dimensional turbo spin echo with a distributed spiral‐in/out trajectory Z Li, M Schär, D Wang, NR Zwart, AJ Madhuranthakam, JP Karis, JG Pipe Magnetic resonance in medicine 75 (1), 266-273, 2016 | 33 | 2016 |
Analytical three‐point Dixon method: With applications for spiral water–fat imaging D Wang, NR Zwart, Z Li, M Schär, JG Pipe Magnetic resonance in medicine 75 (2), 627-638, 2016 | 30 | 2016 |
Sliding‐slab three‐dimensional TSE imaging with a spiral‐in/out readout Z Li, D Wang, RK Robison, NR Zwart, M Schär, JP Karis, JG Pipe Magnetic resonance in medicine 75 (2), 729-738, 2016 | 28 | 2016 |
Dixon water‐fat separation in PROPELLER MRI acquired with two interleaved echoes M Schär, H Eggers, NR Zwart, Y Chang, A Bakhru, JG Pipe Magnetic resonance in medicine 75 (2), 718-728, 2016 | 27 | 2016 |
The effects of SENSE on PROPELLER imaging Y Chang, JG Pipe, JP Karis, WN Gibbs, NR Zwart, M Schär Magnetic resonance in medicine 74 (6), 1598-1608, 2015 | 27 | 2015 |
Multi-frequency interpolation in spiral magnetic resonance fingerprinting for correction of off-resonance blurring J Ostenson, RK Robison, NR Zwart, EB Welch Magnetic resonance imaging 41, 63-72, 2017 | 24 | 2017 |
Fast, variable system delay correction for spiral MRI PS Bhavsar, NR Zwart, JG Pipe Magnetic Resonance in Medicine 71 (2), 773-782, 2014 | 18 | 2014 |
Spiral T1 spin-echo for routine postcontrast brain MRI exams: a multicenter multireader clinical evaluation MB Ooi, Z Li, RK Robison, D Wang, AG Anderson, NR Zwart, A Bakhru, ... American Journal of Neuroradiology 41 (2), 238-245, 2020 | 17 | 2020 |
Freeing MRI from its Faraday cage with Interference Rejection H Dyvorne, T Rearick, M Poole, C Lazarus, P Weiss, L Sacolick, J Jordan, ... Proceedings of the 29th Annual Meeting of ISMRM 749, 2021 | 9 | 2021 |
Spiral CG deblurring and fat-water separation using a multi-peak fat model NR Zwart, D Wang, JG Pipe Proceedings of the Joint Annual Meeting of ISMRM-ESMRMB, Milan, Italy, 2014 | 7 | 2014 |
Use environments and clinical feasibility of portable point-of-care bedside brain MRI EB Welch, S By, G Chen, H Dyvorne, C Hugon, C McNulty Proceedings of the ISMRM. Virtual, 2020 | 3 | 2020 |