Polymeric composite materials for radiation shielding: a review CV More, Z Alsayed, MS Badawi, AA Thabet, PP Pawar Environmental chemistry letters 19, 2057-2090, 2021 | 376 | 2021 |
Fabrication, characterization and gamma rays shielding properties of nano and micro lead oxide-dispersed-high density polyethylene composites ME Mahmoud, AM El-Khatib, MS Badawi, AR Rashad, RM El-Sharkawy, ... Radiation Physics and Chemistry 145, 160-173, 2018 | 202 | 2018 |
Recycled high-density polyethylene plastics added with lead oxide nanoparticles as sustainable radiation shielding materials ME Mahmoud, AM El-Khatib, MS Badawi, AR Rashad, RM El-Sharkawy, ... Journal of cleaner production 176, 276-287, 2018 | 143 | 2018 |
Investigation of γ-ray attenuation coefficients, effective atomic number and electron density for ZnO/HDPE composite Z Alsayed, MS Badawi, R Awad, AM El-Khatib, AA Thabet Physica Scripta 95 (8), 085301, 2020 | 52 | 2020 |
An empirical formula to calculate the full energy peak efficiency of scintillation detectors MS Badawi, M Abd-Elzaher, AA Thabet, AM El-khatib Applied Radiation and Isotopes 74, 46-49, 2013 | 40 | 2013 |
Study of some γ-ray attenuation parameters for new shielding materials composed of nano ZnO blended with high density polyethylene Z Alsayed, MS Badawi, R Awad, AA Thabet, AM El-Khatib Nuclear Technology and Radiation Protection 34 (4), 342-352, 2019 | 38 | 2019 |
Characterization of the efficiency of a cubic NaI detector with rectangular cavity for axially positioned sources MS Badawi, S Noureddine, YN Kopatch, MI Abbas, IN Ruskov, ... Journal of Instrumentation 15 (02), P02013, 2020 | 37 | 2020 |
Full-Energy peak efficiency of an NaI (Tl) detector with coincidence summing correction showing the effect of the source-to-detector distance AM El-Khatib, BA Salem, MS Badawi, MM Gouda, AA Thabet, MI Abbas Chinese journal of Physics 55 (2), 478-489, 2017 | 36 | 2017 |
Efficiency of a cubic NaI (Tl) detector with rectangular cavity using standard radioactive point sources placed at non-axial position MI Abbas, MS Badawi, AA Thabet, YN Kopatch, IN Ruskov, ... Applied Radiation and Isotopes 163, 109139, 2020 | 33 | 2020 |
Study on the effect of the self-attenuation coefficient on γ-ray detector efficiency calculated at low and high energy regions AM El-Khatib, AA Thabet, MA Elzaher, MS Badawi, BA Salem Nuclear Engineering and Technology 46 (2), 217-224, 2014 | 33 | 2014 |
Calibration of well-type NaI (Tl) detector using a point sources measured out the detector well at different axial distances MM Gouda, MS Badawi, AM El-Khatib, MM Mohamed, AA Thabet, ... Journal of Instrumentation 10 (03), P03022, 2015 | 32 | 2015 |
A numerical approach to calculate the full-energy peak efficiency of HPGe well-type detectors using the effective solid angle ratio MS Badawi, I Ruskov, MM Gouda, AM El-Khatib, MF Alotiby, ... Journal of Instrumentation 9 (07), P07030, 2014 | 32 | 2014 |
Calibration of а single hexagonal NaI (Tl) detector using a new numerical method based on the efficiency transfer method MI Abbas, MS Badawi, IN Ruskov, AM El-Khatib, DN Grozdanov, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2015 | 31 | 2015 |
Extensive theoretical study of gamma-ray shielding parameters using epoxy resin-metal chloride mixtures CV More, PP Pawar, MS Badawi, AA Thabet Nuclear Technology and Radiation Protection 35 (2), 138-149, 2020 | 30 | 2020 |
Mathematical method to calculate full-energy peak efficiency of detectors based on transfer technique MM Gouda, A Hamzawy, MS Badawi, AM El-Khatib, AA Thabet, MI Abbas Indian Journal of Physics 90, 201-210, 2016 | 30 | 2016 |
Determination of full energy peak efficiency of NaI (Tl) detector depending on efficiency transfer principle for conversion form experimental values M Abd-Elzaher, MS Badawi, A El-Khatib, AA Thabet Scientific Research Publishing, 2012 | 28 | 2012 |
Calibration of 4π NaI (Tl) detectors with coincidence summing correction using new numerical procedure and ANGLE4 software MS Badawi, SI Jovanovic, AA Thabet, AM El-Khatib, AD Dlabac, ... AIP Advances 7 (3), 2017 | 27 | 2017 |
Experimental verification of gamma-efficiency calculations for scintillation detectors in ANGLE 4 software AA Thabet, AD Dlabac, SI Jovanovic, MS Badawi, NN Mihaljevic, ... Nuclear Technology and Radiation Protection 30 (1), 35-46, 2015 | 27 | 2015 |
NaI cubic detector full-energy peak efficiency, including coincidence and self-absorption corrections for rectangular sources using analytical method MI Abbas, M Elsafi, MM Gouda, M Abd-Elzaher, A Hamzawy, MS Badawi, ... Journal of Radioanalytical and Nuclear Chemistry 327, 251-258, 2021 | 23 | 2021 |
Well-type NaI (Tl) detector efficiency using analytical technique and ANGLE 4 software based on radioactive point sources located out the well cavity AM El-Khatib, MS Badawi, AA Thabet, SI Jovanovic, MM Gouda, ... Chinese Journal of Physics 54 (3), 338-346, 2016 | 23 | 2016 |