关注
Daniel Gomez-Cardona, PhD, DABR
Daniel Gomez-Cardona, PhD, DABR
Diagnostic Medical Physicist, Gundersen Health System
在 gundersenhealth.org 的电子邮件经过验证
标题
引用次数
引用次数
年份
Small (< 4 cm) renal masses: differentiation of angiomyolipoma without visible fat from renal cell carcinoma using unenhanced and contrast-enhanced CT
N Takahashi, S Leng, K Kitajima, D Gomez-Cardona, P Thapa, RE Carter, ...
American Journal of Roentgenology 205 (6), 1194-1202, 2015
742015
Small (< 4 cm) renal mass: differentiation of oncocytoma from renal cell carcinoma on biphasic contrast-enhanced CT
K Sasaguri, N Takahashi, D Gomez-Cardona, S Leng, GD Schmit, ...
American Journal of Roentgenology 205 (5), 999-1007, 2015
722015
Subjective and objective heterogeneity scores for differentiating small renal masses using contrast-enhanced CT
S Leng, N Takahashi, DG Cardona, K Kitajima, B McCollough, Z Li, ...
Abdominal Radiology 42 (5), 1485-1492, 2017
432017
MRI radiomics for assessment of molecular subtype, pathological complete response, and residual cancer burden in breast cancer patients treated with neoadjuvant chemotherapy
S Choudhery, D Gomez-Cardona, CP Favazza, TL Hoskin, TC Haddad, ...
Academic radiology, 2020
422020
Hi‐Res scan mode in clinical MDCT systems: Experimental assessment of spatial resolution performance
JP Cruz‐Bastida, D Gomez‐Cardona, K Li, H Sun, J Hsieh, ...
Medical physics 43 (5), 2399-2409, 2016
302016
Quantitative accuracy of CT numbers: Theoretical analyses and experimental studies
R Zhang, JP Cruz‐Bastida, D Gomez‐Cardona, JW Hayes, K Li, GH Chen
Medical physics 45 (10), 4519-4528, 2018
262018
Radiation dose reduction in dual-energy CT: does it affect the accuracy of urinary stone characterization?
M Qu, L Yu, DG Cardona, Y Liu, X Duan, S Ai, S Leng, M Shiung, ...
American Journal of Roentgenology 205 (2), W172-W176, 2015
192015
Low‐dose cone‐beam CT via raw counts domain low‐signal correction schemes: Performance assessment and task‐based parameter optimization (Part I: Assessment of spatial …
JW Hayes, D Gomez‐Cardona, R Zhang, K Li, JP Cruz‐Bastida, GH Chen
Medical physics 45 (5), 1942-1956, 2018
182018
Statistical model based iterative reconstruction in clinical CT systems. Part III. Task‐based kV/mAs optimization for radiation dose reduction
K Li, D Gomez‐Cardona, J Hsieh, MG Lubner, PJ Pickhardt, GH Chen
Medical physics 42 (9), 5209-5221, 2015
172015
Impact of noise reduction schemes on quantitative accuracy of CT numbers
JP Cruz‐Bastida, R Zhang, D Gomez‐Cardona, J Hayes, K Li, GH Chen
Medical physics, 2019
112019
Impact of bowtie filter and object position on the two‐dimensional noise power spectrum of a clinical MDCT system
D Gomez‐Cardona, JP Cruz‐Bastida, K Li, A Budde, J Hsieh, GH Chen
Medical physics 43 (8Part1), 4495-4506, 2016
112016
Low‐dose cone‐beam CT via raw counts domain low‐signal correction schemes: Performance assessment and task‐based parameter optimization (Part II. Task‐based parameter optimization)
D Gomez‐Cardona, JW Hayes, R Zhang, K Li, JP Cruz‐Bastida, GH Chen
Medical physics 45 (5), 1957-1969, 2018
102018
Modified ideal observer model (MIOM) for high‐contrast and high‐spatial resolution CT imaging tasks
JP Cruz‐Bastida, D Gomez‐Cardona, J Garrett, T Szczykutowicz, ...
Medical physics 44 (9), 4496-4505, 2017
102017
Can conclusions drawn from phantom‐based image noise assessments be generalized to in vivo studies for the nonlinear model‐based iterative reconstruction …
D Gomez‐Cardona, K Li, J Hsieh, MG Lubner, PJ Pickhardt, GH Chen
Medical physics 43 (2), 687-695, 2016
102016
Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study
D Gomez‐Cardona, SK Nagle, K Li, TE Robinson, GH Chen
Medical physics 42 (10), 5919-5927, 2015
102015
Unbiased statistical image reconstruction in low-dose CT
J Hayes, R Zhang, C Zhang, D Gomez-Cardona, GH Chen
Medical Imaging 2019: Physics of Medical Imaging 10948, 1094859, 2019
82019
Low signal correction scheme for low dose CBCT: the good, the bad, and the ugly
D Gomez-Cardona, J Hayes, R Zhang, K Li, JP Cruz-Bastida, GH Chen
Medical Imaging 2017: Physics of Medical Imaging 10132, 101320Z, 2017
72017
Noise performance studies of model-based iterative reconstruction (MBIR) as a function of kV, mA and exposure level: Impact on radiation dose reduction and image quality
D Gomez-Cardona, K Li, MG Lubner, PJ Pickhardt, GH Chen
Medical Imaging 2015: Physics of Medical Imaging 9412, 941238, 2015
62015
Impact of radiation dose level on CT number accuracy in photon counting CT
R Zhang, JP Cruz-Bastida, D Gomez-Cardona, J Hayes, K Li, GH Chen
Medical Imaging 2018: Physics of Medical Imaging 10573, 105734T, 2018
42018
Quantitative low-dose CT: potential value of low signal correction methods
JP Cruz-Bastida, R Zhang, D Gomez-Cardona, GH Chen
Medical Imaging 2019: Physics of Medical Imaging 10948, 1094830, 2019
32019
系统目前无法执行此操作,请稍后再试。
文章 1–20