TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow maps AM Mendrik, E Vonken, B van Ginneken, HW de Jong, A Riordan, ... Physics in Medicine & Biology 56 (13), 3857, 2011 | 104 | 2011 |
Validation of CT brain perfusion methods using a realistic dynamic head phantom AJ Riordan, M Prokop, MA Viergever, JW Dankbaar, EJ Smit, ... Medical physics 38 (6Part1), 3212-3221, 2011 | 62 | 2011 |
Head movement during CT brain perfusion acquisition of patients with suspected acute ischemic stroke F Fahmi, LFM Beenen, GJ Streekstra, NY Janssen, HW de Jong, ... European journal of radiology 82 (12), 2334-2341, 2013 | 51 | 2013 |
Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction JM Niesten, IC van der Schaaf, AJ Riordan, HWAM de Jong, AD Horsch, ... European radiology 24, 484-493, 2014 | 50 | 2014 |
Effect of extended CT perfusion acquisition time on ischemic core and penumbra volume estimation in patients with acute ischemic stroke due to a large vessel occlusion J Borst, HA Marquering, LFM Beenen, OA Berkhemer, JW Dankbaar, ... PLoS One 10 (3), e0119409, 2015 | 41 | 2015 |
A fast nonlinear regression method for estimating permeability in CT perfusion imaging E Bennink, AJ Riordan, AD Horsch, JW Dankbaar, BK Velthuis, ... Journal of Cerebral Blood Flow & Metabolism 33 (11), 1743-1751, 2013 | 34 | 2013 |
The effect of head movement on CT perfusion summary maps: simulations with CT hybrid phantom data F Fahmi, A Riordan, LFM Beenen, GJ Streekstra, NY Janssen, ... Medical & biological engineering & computing 52, 141-147, 2014 | 19 | 2014 |
CT brain perfusion protocol to eliminate the need for selecting a venous output function AJ Riordan, E Bennink, MA Viergever, BK Velthuis, JW Dankbaar, ... American Journal of Neuroradiology 34 (7), 1353-1358, 2013 | 12 | 2013 |
Optimisation of vascular input and output functions in CT-perfusion imaging using 256 (or more)-slice multidetector CT JM Niesten, IC van der Schaaf, AJ Riordan, HWAM de Jong, WPTM Mali, ... European radiology 23, 1242-1249, 2013 | 10 | 2013 |
Comparison of partial volume effects in arterial and venous contrast curves in CT brain perfusion imaging AJ Riordan, E Bennink, JW Dankbaar, MA Viergever, BK Velthuis, EJ Smit, ... Plos one 9 (5), e97586, 2014 | 3 | 2014 |
Computed tomography perfusion evaluation after extracranial–intracranial bypass surgery PC Vos, AJ Riordan, EJ Smit, HWAM de Jong, A van der Zwan, ... Clinical Neurology and Neurosurgery 136, 139-146, 2015 | 1 | 2015 |
Automatic selection of CT perfusion datasets unsuitable for CTP analysis due to head movement F Fahmi, HA Marquering, GJ Streekstra, LFM Beenen, NY Janssen, ... XIII Mediterranean Conference on Medical and Biological Engineering and …, 2014 | 1 | 2014 |
nieuw licht op de vochtbalans tijdens inspanning C Bongers, A Riordan, M Hopman, T Eijsvogels, T van Leeuwen Sportgericht 70 (3), 56-60, 2016 | | 2016 |
Development and evaluation of CT acquisition and analysis methods of brain perfusion AJ Riordan Brain Center Rudolf Magnus 59, 2014 | | 2014 |
Ischemic core estimation in patients with acute ischemic stroke: Effect of extended CT perfusion acquisition time J Borst, HA Marquering, LFM Beenen, OA Berkhemer, JW Dankbaar, ... INTERNATIONAL JOURNAL OF STROKE 9, 43-43, 2014 | | 2014 |
The Effect of Head Movement on CT Perfusion Summary Maps: Simulations with CT Hybrid Phantom Data A Riordan, LFM Beenen, GJ Streekstra, NY Janssen, HW de Jong, ... Universitas Sumatera Utara, 2014 | | 2014 |
IMPROVEMENTS IN ACCURACY AND DOSE EFFICIENCY OF CTP BY APPLICATION OF A REALISTIC DIGITAL PHANTOM AJ Riordan, E Bennink, MA Viergever, HWAM de Jong Development and evaluation of CT acquisition and analysis methods of brain …, 2014 | | 2014 |
Two-Step Clustering Technique Can Halve Radiation Dose in CT Brain Perfusion Measurements H de Jong, A Riordan, JW Dankbaar, EJ Smit, BK Velthuis, M Prokop RSNA}}, 0 | | |