关注
Michael Crichton
Michael Crichton
Institute of Mechanical, Process and Energy Engineering, Heriot-Watt University, Edinburgh, UK
在 hw.ac.uk 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Allometric scaling of skin thickness, elasticity, viscoelasticity to mass for micro-medical device translation: from mice, rats, rabbits, pigs to humans
JCJ Wei, GA Edwards, DJ Martin, H Huang, ML Crichton, MAF Kendall
Scientific reports 7 (1), 15885, 2017
2632017
Dry-coated microprojection array patches for targeted delivery of immunotherapeutics to the skin
X Chen, TW Prow, ML Crichton, DWK Jenkins, MS Roberts, IH Frazer, ...
Journal of controlled release 139 (3), 212-220, 2009
2222009
Nanopatch‐targeted skin vaccination against West Nile virus and chikungunya virus in mice
TW Prow, X Chen, NA Prow, GJP Fernando, CSE Tan, AP Raphael, ...
Small 6 (16), 1776-1784, 2010
2142010
Improving the reach of vaccines to low-resource regions, with a needle-free vaccine delivery device and long-term thermostabilization
X Chen, GJP Fernando, ML Crichton, C Flaim, SR Yukiko, EJ Fairmaid, ...
Journal of controlled release 152 (3), 349-355, 2011
2032011
Potent immunity to low doses of influenza vaccine by probabilistic guided micro-targeted skin delivery in a mouse model
GJP Fernando, X Chen, TW Prow, ML Crichton, EJ Fairmaid, MS Roberts, ...
PloS one 5 (4), e10266, 2010
1902010
Targeted, needle‐free vaccinations in skin using multilayered, densely‐packed dissolving microprojection arrays
AP Raphael, TW Prow, ML Crichton, X Chen, GJP Fernando, ...
Small 6 (16), 1785-1793, 2010
1802010
The viscoelastic, hyperelastic and scale dependent behaviour of freshly excised individual skin layers
ML Crichton, BC Donose, X Chen, AP Raphael, H Huang, MAF Kendall
Biomaterials 32 (20), 4670-4681, 2011
1742011
The effect of strain rate on the precision of penetration of short densely-packed microprojection array patches coated with vaccine
ML Crichton, A Ansaldo, X Chen, TW Prow, GJP Fernando, MAF Kendall
Biomaterials 31 (16), 4562-4572, 2010
1452010
Improved DNA vaccination by skin-targeted delivery using dry-coated densely-packed microprojection arrays
X Chen, AS Kask, ML Crichton, C McNeilly, S Yukiko, L Dong, ...
Journal of controlled release 148 (3), 327-333, 2010
1022010
Formulations for microprojection/microneedle vaccine delivery: Structure, strength and release profiles
AP Raphael, ML Crichton, RJ Falconer, S Meliga, X Chen, GJP Fernando, ...
Journal of controlled release 225, 40-52, 2016
912016
Elastic modulus and viscoelastic properties of full thickness skin characterised at micro scales
ML Crichton, X Chen, H Huang, MAF Kendall
Biomaterials 34 (8), 2087-2097, 2013
892013
Surface-modified microprojection arrays for intradermal biomarker capture, with low non-specific protein binding
SR Corrie, GJP Fernando, ML Crichton, MEG Brunck, CD Anderson, ...
Lab on a Chip 10 (20), 2655-2658, 2010
822010
Dry-coated live viral vector vaccines delivered by nanopatch microprojections retain long-term thermostability and induce transgene-specific T cell responses in mice
FE Pearson, CL McNeilly, ML Crichton, CA Primiero, SR Yukiko, ...
PloS one 8 (7), e67888, 2013
782013
Inactivated poliovirus type 2 vaccine delivered to rat skin via high density microprojection array elicits potent neutralising antibody responses
DA Muller, FE Pearson, GJP Fernando, C Agyei-Yeboah, NS Owens, ...
Scientific reports 6 (1), 22094, 2016
462016
Space-and time-resolved investigation on diffusion kinetics of human skin following macromolecule delivery by microneedle arrays
JCJ Wei, IN Haridass, ML Crichton, YH Mohammed, SC Meliga, ...
Scientific Reports 8 (1), 17759, 2018
412018
The hyperelastic and failure behaviors of skin in relation to the dynamic application of microscopic penetrators in a murine model
SC Meliga, JW Coffey, ML Crichton, C Flaim, M Veidt, MAF Kendall
Acta biomaterialia 48, 341-356, 2017
412017
Delivery device
MAF Kendall, S Meliga, ACI Depelsenaire, ML Crichton, C Flaim
US Patent 11,179,553, 2021
402021
The developmental basis of fingerprint pattern formation and variation
JD Glover, ZR Sudderick, BBJ Shih, C Batho-Samblas, L Charlton, ...
Cell 186 (5), 940-956. e20, 2023
382023
Microprojection arrays to immunise at mucosal surfaces
CL McNeilly, ML Crichton, CA Primiero, IH Frazer, MS Roberts, ...
Journal of Controlled Release 196, 252-260, 2014
372014
Sensors for fetal hypoxia and metabolic acidosis: a review
G Cummins, J Kremer, A Bernassau, A Brown, HL Bridle, H Schulze, ...
Sensors 18 (8), 2648, 2018
332018
系统目前无法执行此操作,请稍后再试。
文章 1–20