EGS4 code system WR Nelson, H Hirayama, DWO Rogers Stanford Linear Accelerator Center, Menlo Park, CA (USA), 1985 | 3884* | 1985 |
EGSnrc toolkit for Monte Carlo simulation of ionizing radiation transport I Kawrakow, DWO Rogers, E Mainegra-Hing, F Tessier, RW Townson, ... EGSnrc toolkit for Monte Carlo simulation of ionizing radiation transport, 2000 | 2412* | 2000 |
AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beams PR Almond, PJ Biggs, BM Coursey, WF Hanson, MS Huq, R Nath, ... Medical physics 26 (9), 1847-1870, 1999 | 2028 | 1999 |
BEAM: a Monte Carlo code to simulate radiotherapy treatment units DWO Rogers, BA Faddegon, GX Ding, CM Ma, J We, TR Mackie Medical physics 22 (5), 503-524, 1995 | 1894 | 1995 |
BEAMnrc users manual DWO Rogers, B Walters, I Kawrakow Nrc Report Pirs 509, 12, 2009 | 913 | 2009 |
Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning IJ Chetty, B Curran, JE Cygler, JJ DeMarco, G Ezzell, BA Faddegon, ... Medical physics 34 (12), 4818-4853, 2007 | 874 | 2007 |
DOSXYZnrc users manual B Walters, I Kawrakow, DWO Rogers NRC Report PIRS 794, 2005 | 822 | 2005 |
Fifty years of Monte Carlo simulations for medical physics DWO Rogers Physics in Medicine & Biology 51 (13), R287, 2006 | 734 | 2006 |
Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code D Sheikh‐Bagheri, DWO Rogers Medical physics 29 (3), 391-402, 2002 | 683 | 2002 |
PRESTA: the parameter reduced electron-step transport algorithm for electron Monte Carlo transport AF Bielajew, DWO Rogers Nuclear Instruments and Methods in Physics Research Section B: Beam …, 1986 | 672 | 1986 |
NRC user codes for EGSnrc DWO Rogers, I Kawrakow, JP Seuntjens, BRB Walters, E Mainegra-Hing NRCC Report PIRS-702 (Rev. B), 2003 | 442 | 2003 |
Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters D Sheikh‐Bagheri, DWO Rogers Medical physics 29 (3), 379-390, 2002 | 407 | 2002 |
Generation of photon energy deposition kernels using the EGS Monte Carlo code TR Mackie, AF Bielajew, DWO Rogers, JJ Battista Physics in medicine and biology 33 (1), 1, 1988 | 378 | 1988 |
Addendum to the AAPMˈs TG‐51 protocol for clinical reference dosimetry of high‐energy photon beams M McEwen, L DeWerd, G Ibbott, D Followill, DWO Rogers, S Seltzer, ... Medical physics 41 (4), 041501, 2014 | 326 | 2014 |
Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting: directional bremsstrahlung splitting I Kawrakow, DWO Rogers, BRB Walters Medical physics 31 (10), 2883-2898, 2004 | 319 | 2004 |
Monte Carlo techniques of electron and photon transport for radiation dosimetry DWO Rogers, AF Bielajew The dosimetry of ionizing radiation 3, 427-539, 1990 | 305 | 1990 |
History by history statistical estimators in the BEAM code system BRB Walters, I Kawrakow, DWO Rogers Medical physics 29 (12), 2745-2752, 2002 | 284 | 2002 |
Monte Carlo simulation of a typical therapy source GM Mora, A Maio, DWO Rogers Medical physics 26 (11), 2494-2502, 1999 | 251 | 1999 |
RECORDS: improved reporting of montE CarlO RaDiation transport studies: report of the AAPM Research Committee Task Group 268 I Sechopoulos, DWO Rogers, M Bazalova‐Carter, WE Bolch, EC Heath, ... Medical physics 45 (1), e1-e5, 2018 | 229 | 2018 |
Dosimetry of 125I and 103Pd COMS eye plaques for intraocular tumors: Report of Task Group 129 by the AAPM and ABS ST Chiu‐Tsao, MA Astrahan, PT Finger, DS Followill, AS Meigooni, ... Medical physics 39 (10), 6161-6184, 2012 | 217 | 2012 |