Comparative analysis of multi‐criteria decision‐making methods for seismic structural retrofitting N Caterino, I Iervolino, G Manfredi, E Cosenza Computer‐Aided Civil and Infrastructure Engineering 24 (6), 432-445, 2009 | 192 | 2009 |
Multi-criteria decision making for seismic retrofitting of RC structures N Caterino, I Iervolino, G Manfredi, E Cosenza Journal of Earthquake Engineering 12 (4), 555-583, 2008 | 119 | 2008 |
Semi-active control of a wind turbine via magnetorheological dampers N Caterino Journal of Sound and Vibration 345, 1-17, 2015 | 110 | 2015 |
Experimental and analytical characterization of steel shear links for seismic energy dissipation I Nuzzo, D Losanno, N Caterino, G Serino, LMB Rotondo Engineering Structures 172, 405-418, 2018 | 67 | 2018 |
Seismic design and retrofit of frame structures with hysteretic dampers: a simplified displacement-based procedure I Nuzzo, D Losanno, N Caterino Bulletin of Earthquake Engineering 17, 2787-2819, 2019 | 61 | 2019 |
A comparative analysis of decision making methods for the seismic retrofit of RC buildings N Caterino, I Iervolino, G Manfredi, E Cosenza The 14th world conference on earthquake engineering, 12-17, 2008 | 59 | 2008 |
Seismic assessment and finite element modelling of glazed curtain walls N Caterino, M Del Zoppo, G Maddaloni, A Bonati, G Cavanna, ... Struct. Eng. Mech 61 (1), 77-90, 2017 | 54 | 2017 |
Experimental and numerical investigation of cyclic response of a glass curtain wall for seismic performance assessment C Aiello, N Caterino, G Maddaloni, A Bonati, A Franco, A Occhiuzzi Construction and Building Materials 187, 596-609, 2018 | 48 | 2018 |
Understanding and modelling the physical behaviour of magnetorheological dampers for seismic structural control N Caterino, M Spizzuoco, A Occhiuzzi Smart Materials and Structures 20 (6), 065013, 2011 | 47 | 2011 |
Semi-active control of the benchmark highway bridge based on seismic early warning systems G Maddaloni, N Caterino, A Occhiuzzi Bulletin of Earthquake Engineering 9, 1703-1715, 2011 | 44 | 2011 |
Numerical investigation on the seismic dissipation of glazed curtain wall equipped on high-rise buildings L Casagrande, A Bonati, A Occhiuzzi, N Caterino, F Auricchio Engineering Structures 179, 225-245, 2019 | 33 | 2019 |
Promptness and dissipative capacity of MR dampers: experimental investigations N Caterino, M Spizzuoco, A Occhiuzzi Structural Control and Health Monitoring 20 (12), 1424-1440, 2013 | 31 | 2013 |
A multi-criteria approach for selecting the seismic retrofit intervention for an existing structure accounting for expected losses and tax incentives in Italy N Caterino, E Cosenza Engineering Structures 174, 840-850, 2018 | 29 | 2018 |
Shake table investigation of a structure isolated by recycled rubber devices and magnetorheological dampers G Maddaloni, N Caterino, A Occhiuzzi Structural Control and Health Monitoring 24 (5), e1906, 2017 | 29 | 2017 |
Approximate methods to evaluate storey stiffness and interstory drift of RC buildings in seismic area N Caterino, E Cosenza, BM Azmoodeh Structural engineering and mechanics 46 (2), 245-267, 2013 | 29 | 2013 |
A BIM-based decision-making framework for optimal seismic retrofit of existing buildings N Caterino, I Nuzzo, A Ianniello, G Varchetta, E Cosenza Engineering Structures 242, 112544, 2021 | 27 | 2021 |
Use of seismic early warning information to calibrate variable dampers for structural control of a highway bridge: evaluation of the system robustness G Maddaloni, N Caterino, G Nestovito, A Occhiuzzi Bulletin of Earthquake Engineering 11, 2407-2428, 2013 | 26 | 2013 |
Medium to long term behavior of MR dampers for structural control N Caterino, BM Azmoodeh, A Occhiuzzi Smart Materials and Structures 23 (11), 117005, 2014 | 24 | 2014 |
Shaking table testing of a steel frame structure equipped with semi-active MR dampers: comparison of control algorithms N Caterino, M Spizzuoco, A Occhiuzzi Smart Structures and Systems 15 (4), 963-995, 2015 | 19 | 2015 |
A semi-active control system for wind turbines N Caterino, CT Georgakis, F Trinchillo, A Occhiuzzi Wind Turbine Control and Monitoring, 375-407, 2014 | 17 | 2014 |