Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. D Li, S Kaushikkar, EM Haacke, PK Woodard, PJ Dhawale, RM Kroeker, ... Radiology 201 (3), 857-863, 1996 | 286 | 1996 |
Myocardial signal response to dipyridamole and dobutamine: demonstration of the BOLD effect using a double‐echo gradient‐echo sequence D Li, P Dhawale, PJ Rubin, EM Haacke, RJ Gropler Magnetic resonance in medicine 36 (1), 16-20, 1996 | 148 | 1996 |
Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: preliminary experience. PK Woodard, D Li, EM Haacke, PJ Dhawale, S Kaushikkar, B Barzilai, ... AJR. American journal of roentgenology 170 (4), 883-888, 1998 | 140 | 1998 |
Intracoronary ultrasound—defined plaque composition: Computer-aided plaque characterization and correlation with histologic samples obtained during directional coronary … Q Rasheed, PJ Dhawale, J Anderson, JMB Hodgson American heart journal 129 (4), 631-637, 1995 | 128 | 1995 |
MR lymphangiography: imaging strategies to optimize the imaging of lymph nodes with ferumoxtran-10 MG Harisinghani, WT Dixon, MA Saksena, E Brachtel, DJ Blezek, ... Radiographics 24 (3), 867-878, 2004 | 108 | 2004 |
Systems, methods and apparatus for preparation, delivery and monitoring of radioisotopes in positron emission tomography PJ Dhawale, MA Jackson, HR Lara, M Brussermann, U Ketzscher US Patent 7,734,331, 2010 | 79 | 2010 |
Systems, methods and apparatus for infusion of radiopharmaceuticals MA Jackson, PJ Dhawale, HR Lara, M Brussermann, U Ketzscher US Patent 9,627,097, 2017 | 68 | 2017 |
Measurement by intracoronary ultrasound of in vivo arterial distensibility within atherosclerotic lesions KG Reddy, R Suneja, RN Nair, P Dhawale, JMB Hodgson The American journal of cardiology 72 (17), 1232-1237, 1993 | 36 | 1993 |
Method and apparatus for performing fluoroscopic noise reduction PJ Dhawale, T Lebihen, GM Kautz US Patent 6,314,160, 2001 | 30 | 2001 |
Optimal data acquisition for volumetric intracoronary ultrasound PJ Dhawale, DL Wilson, JMB Hodgson Catheterization and cardiovascular diagnosis 32 (3), 288-299, 1994 | 27 | 1994 |
Fat/water separation and fat minimization magnetic resonance imaging systems and methods D Blezek, P Dhawale, W Dixon US Patent 7,099,499, 2006 | 24 | 2006 |
Volumetric intracoronary ultrasound: methods and validation PJ Dhawale, DL Wilson, JMB Hodgson Catheterization and cardiovascular diagnosis 33 (4), 296-307, 1994 | 19 | 1994 |
Systems and methods for high-resolution in vivo imaging of biochemical activity in a living organism I Hancu, MM Amaratunga, DK Wicht, P Dhawale, N Ishaque, FA Syud, ... US Patent 7,303,741, 2007 | 15 | 2007 |
Intracoronary ultrasound plaque volume quantification PJ Dhawale, Q Rasheed, N Griffin, DL Wilson, JMB Hodgson Proceedings of Computers in Cardiology Conference, 121-124, 1993 | 13 | 1993 |
Calibrated 3-D reconstruction of intracoronary ultrasound images with cardiac gating and catheter motion compensation PJ Dhawale, N Griffin, DL Wilson, JM Hodgson Proceedings Computers in Cardiology, 31-34, 1992 | 11 | 1992 |
Method and apparatus for reducing spectrally-sensitive artifacts PJ Dhawale, D Albagli US Patent 6,879,660, 2005 | 10 | 2005 |
Three-dimensional MRI of coronary arteries (abstr) D Li, S Kaushikkar, P Woodard, P Dhawale, EM Haacke Book of Abstracts of Seventh International Workshop on Magnetic Resonance …, 1995 | 10 | 1995 |
ANALYSIS OF PLAQUE VOLUME DURING DCA USING A VOLUMETRICALLY ACCURATE 3-DIMENSIONAL ULTRASOUND TECHNIQUE PJ Dhawale, Q Rasheed, W Mecca, R Nair, JM Hodgson Circulation 88 (4), 550-550, 1993 | 10 | 1993 |
Three-dimensional imaging of coronary arteries with retrospective respiratory gating D Li, S Kaushikkar, EM Haacke, PK Woodard, P Dhawale, RM Kroeker, ... Radiology 201, 857-863, 1996 | 9 | 1996 |
Estimation of hypoxic ventilatory dynamics using pseudorandom inputs P Dhawale, EN Bruce Respiration physiology 101 (3), 267-278, 1995 | 9 | 1995 |