Detection of local lung air content by electrical impedance tomography compared with electron beam CT I Frerichs, J Hinz, P Herrmann, G Weisser, G Hahn, T Dudykevych, ... Journal of applied physiology 93 (2), 660-666, 2002 | 383 | 2002 |
Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs J Hinz, P Neumann, T Dudykevych, LG Andersson, H Wrigge, H Burchardi, ... Chest 124 (1), 314-322, 2003 | 203 | 2003 |
Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution? I Frerichs, PA Dargaville, T Dudykevych, PC Rimensberger Intensive care medicine 29, 2312-2316, 2003 | 178 | 2003 |
Gravity effects on regional lung ventilation determined by functional EIT during parabolic flights I Frerichs, T Dudykevych, J Hinz, M Bodenstein, G Hahn, G Hellige Journal of applied physiology 91 (1), 39-50, 2001 | 135 | 2001 |
Imaging pathologic pulmonary air and fluid accumulation by functional and absolute EIT G Hahn, A Just, T Dudykevych, I Frerichs, J Hinz, M Quintel, G Hellige Physiological measurement 27 (5), S187, 2006 | 128 | 2006 |
Distribution of lung ventilation in spontaneously breathing neonates lying in different body positions I Frerichs, H Schiffmann, R Oehler, T Dudykevych, G Hahn, J Hinz, ... Intensive care medicine 29, 787-794, 2003 | 118 | 2003 |
Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography J Hinz, O Moerer, P Neumann, T Dudykevych, I Frerichs, G Hellige, ... Acta anaesthesiologica scandinavica 50 (3), 331-339, 2006 | 66 | 2006 |
Distribution of ventilation in young and elderly adults determined by electrical impedance tomography I Frerichs, P Braun, T Dudykevych, G Hahn, D Genée, G Hellige Respiratory physiology & neurobiology 143 (1), 63-75, 2004 | 64 | 2004 |
Effect of positive end-expiratory-pressure on regional ventilation in patients with acute lung injury evaluated by electrical impedance tomography J Hinz, O Moerer, P Neumann, T Dudykevych, G Hellige, M Quintel European journal of anaesthesiology 22 (11), 817-825, 2005 | 53 | 2005 |
Detection of (reversible) myocardial ischemic injury by means of electrical bioimpedance F Mellert, K Winkler, C Schneider, T Dudykevych, A Welz, M Osypka, ... IEEE Transactions on Biomedical Engineering 58 (6), 1511-1518, 2010 | 51 | 2010 |
Impedance analyser module for EIT and spectroscopy using undersampling T Dudykevych, E Gersing, F Thiel, G Hellige Physiological measurement 22 (1), 19, 2001 | 46 | 2001 |
Quantitative Evaluation of the Performance of Different Electrical Tomography Devices-Quantitative Evaluierung der Systemeigenschaften verschiedener Elektrotomographie-Geräte G Hahn, F Thiel, T Dudykevych, I Frerichs, E Gersing, T Schröder, ... Walter de Gruyter, Berlin/New York 46 (4), 91-95, 2001 | 45 | 2001 |
A simple method to check the dynamic performance of electrical impedance tomography systems G Hahn, M Beer, I Frerichs, T Dudykevych, T Schröder, G Hellige Physiological measurement 21 (1), 53, 2000 | 42 | 2000 |
A high performance electrical impedance tomography (EIT) system for clinical evaluation studies and space application G Hahn, T Dudykevych, I Frerichs, F Thiel, G Hellige Proc. Conf. 2nd European Medical and Biol. Eng. Vienna, Austria, 2002 | 36 | 2002 |
Effect of lower body negative pressure and gravity on regional lung ventilation determined by EIT I Frerichs, M Bodenstein, T Dudykevych, J Hinz, G Hahn, G Hellige Physiological measurement 26 (2), S27, 2005 | 24 | 2005 |
Funktionelle elektrische impedanztomographie I Frerichs, H Schiffmann, G Hahn, T Dudykevych, A Just, G Hellige Intensivmedizin und Notfallmedizin 1 (42), 66-73, 2005 | 18 | 2005 |
A concept for evaluation of clinically relevant pulmonary parameters by high performance electrical impedance tomography (EIT) T Dudykevych, G Hahn, I Frerichs, J Hinz, G Hellige Proceedings of the 2nd European Medical and Biological Engineering …, 2002 | 12 | 2002 |
EIT System for clinical and space applications G Hahn, T Dudykevych, I Frerichs, G Hellige Proc 2nd Eur Med Biol Eng Conf 3, 110-111, 2002 | 9 | 2002 |
Increased Reliability of Gas Turbine Components by Robust Coatings Manufacturing A Sharma, T Dudykevych, D Sansom, R Subramanian Journal of Thermal Spray Technology, Volume 26, Issue 6, pp.1084-1094 26 (6 …, 2017 | 7 | 2017 |
Elektrotomographie-System zur Bestimmung der lokalen Ventilationsverteilung in der Schwerelosigkeit T Dudykevych, G Hahn, F Thiel, I Frerichs, E Gersing, T Schröder, ... Walter de Gruyter, Berlin/New York 45 (s1), 71-72, 2000 | 6 | 2000 |