关注
J Webster Stayman
J Webster Stayman
Associate Professor of Biomedical Engineering, Johns Hopkins University
在 jhu.edu 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Dedicated cone-beam CT system for extremity imaging
JA Carrino, A Al Muhit, W Zbijewski, GK Thawait, JW Stayman, N Packard, ...
Radiology 270 (3), 816-824, 2014
2282014
Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction
JW Stayman, JA Fessler
IEEE transactions on medical imaging 19 (6), 601-615, 2000
2252000
A dedicated cone‐beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization
W Zbijewski, P De Jean, P Prakash, Y Ding, JW Stayman, N Packard, ...
Medical physics 38 (8), 4700-4713, 2011
1792011
Analysis of Fourier‐domain task‐based detectability index in tomosynthesis and cone‐beam CT in relation to human observer performance
GJ Gang, J Lee, JW Stayman, DJ Tward, W Zbijewski, JL Prince, ...
Medical physics 38 (4), 1754-1768, 2011
1652011
Monte Carlo study of the effects of system geometry and antiscatter grids on cone‐beam CT scatter distributions
A Sisniega, W Zbijewski, A Badal, IS Kyprianou, JW Stayman, JJ Vaquero, ...
Medical physics 40 (5), 051915, 2013
1462013
Mobile C‐arm cone‐beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance
S Schafer, S Nithiananthan, DJ Mirota, A Uneri, JW Stayman, W Zbijewski, ...
Medical physics 38 (8), 4563-4574, 2011
1442011
Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems
JW Stayman, JA Fessler
IEEE transactions on medical imaging 23 (3), 269-284, 2004
1302004
Demons deformable registration of CT and cone‐beam CT using an iterative intensity matching approach
S Nithiananthan, S Schafer, A Uneri, DJ Mirota, JW Stayman, W Zbijewski, ...
Medical physics 38 (4), 1785-1798, 2011
1142011
High-fidelity artifact correction for cone-beam CT imaging of the brain
A Sisniega, W Zbijewski, J Xu, H Dang, JW Stayman, J Yorkston, N Aygun, ...
Physics in Medicine & Biology 60 (4), 1415, 2015
1102015
Task‐based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation
GJ Gang, JW Stayman, W Zbijewski, JH Siewerdsen
Medical physics 41 (8Part1), 081902, 2014
1042014
Model-based tomographic reconstruction of objects containing known components
JW Stayman, Y Otake, JL Prince, AJ Khanna, JH Siewerdsen
IEEE transactions on medical imaging 31 (10), 1837-1848, 2012
1032012
Robust 3D–2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation
Y Otake, AS Wang, JW Stayman, A Uneri, G Kleinszig, S Vogt, AJ Khanna, ...
Physics in medicine & biology 58 (23), 8535, 2013
952013
Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system
S Demehri, A Muhit, W Zbijewski, JW Stayman, J Yorkston, N Packard, ...
European radiology 25, 1742-1751, 2015
932015
Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion
A Sisniega, JW Stayman, J Yorkston, JH Siewerdsen, W Zbijewski
Physics in Medicine & Biology 62 (9), 3712, 2017
912017
Self-calibration of cone-beam CT geometry using 3D–2D image registration
S Ouadah, JW Stayman, GJ Gang, T Ehtiati, JH Siewerdsen
Physics in Medicine & Biology 61 (7), 2613, 2016
892016
Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery
Y Otake, S Schafer, JW Stayman, W Zbijewski, G Kleinszig, R Graumann, ...
Physics in Medicine & Biology 57 (17), 5485, 2012
842012
Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction
AS Wang, JW Stayman, Y Otake, G Kleinszig, S Vogt, GL Gallia, ...
Physics in Medicine & Biology 59 (4), 1005, 2014
772014
Extra‐dimensional Demons: a method for incorporating missing tissue in deformable image registration
S Nithiananthan, S Schafer, DJ Mirota, JW Stayman, W Zbijewski, DD Reh, ...
Medical physics 39 (9), 5718-5731, 2012
732012
PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction
JW Stayman, H Dang, Y Ding, JH Siewerdsen
Physics in Medicine & Biology 58 (21), 7563, 2013
712013
Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise
S Tilley, JH Siewerdsen, JW Stayman
Physics in Medicine & Biology 61 (1), 296, 2015
702015
系统目前无法执行此操作,请稍后再试。
文章 1–20