Dedicated cone-beam CT system for extremity imaging JA Carrino, A Al Muhit, W Zbijewski, GK Thawait, JW Stayman, N Packard, ... Radiology 270 (3), 816-824, 2014 | 228 | 2014 |
Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction JW Stayman, JA Fessler IEEE transactions on medical imaging 19 (6), 601-615, 2000 | 225 | 2000 |
A dedicated cone‐beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization W Zbijewski, P De Jean, P Prakash, Y Ding, JW Stayman, N Packard, ... Medical physics 38 (8), 4700-4713, 2011 | 179 | 2011 |
Analysis of Fourier‐domain task‐based detectability index in tomosynthesis and cone‐beam CT in relation to human observer performance GJ Gang, J Lee, JW Stayman, DJ Tward, W Zbijewski, JL Prince, ... Medical physics 38 (4), 1754-1768, 2011 | 165 | 2011 |
Monte Carlo study of the effects of system geometry and antiscatter grids on cone‐beam CT scatter distributions A Sisniega, W Zbijewski, A Badal, IS Kyprianou, JW Stayman, JJ Vaquero, ... Medical physics 40 (5), 051915, 2013 | 146 | 2013 |
Mobile C‐arm cone‐beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance S Schafer, S Nithiananthan, DJ Mirota, A Uneri, JW Stayman, W Zbijewski, ... Medical physics 38 (8), 4563-4574, 2011 | 144 | 2011 |
Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems JW Stayman, JA Fessler IEEE transactions on medical imaging 23 (3), 269-284, 2004 | 130 | 2004 |
Demons deformable registration of CT and cone‐beam CT using an iterative intensity matching approach S Nithiananthan, S Schafer, A Uneri, DJ Mirota, JW Stayman, W Zbijewski, ... Medical physics 38 (4), 1785-1798, 2011 | 114 | 2011 |
High-fidelity artifact correction for cone-beam CT imaging of the brain A Sisniega, W Zbijewski, J Xu, H Dang, JW Stayman, J Yorkston, N Aygun, ... Physics in Medicine & Biology 60 (4), 1415, 2015 | 110 | 2015 |
Task‐based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation GJ Gang, JW Stayman, W Zbijewski, JH Siewerdsen Medical physics 41 (8Part1), 081902, 2014 | 104 | 2014 |
Model-based tomographic reconstruction of objects containing known components JW Stayman, Y Otake, JL Prince, AJ Khanna, JH Siewerdsen IEEE transactions on medical imaging 31 (10), 1837-1848, 2012 | 103 | 2012 |
Robust 3D–2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation Y Otake, AS Wang, JW Stayman, A Uneri, G Kleinszig, S Vogt, AJ Khanna, ... Physics in medicine & biology 58 (23), 8535, 2013 | 95 | 2013 |
Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system S Demehri, A Muhit, W Zbijewski, JW Stayman, J Yorkston, N Packard, ... European radiology 25, 1742-1751, 2015 | 93 | 2015 |
Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion A Sisniega, JW Stayman, J Yorkston, JH Siewerdsen, W Zbijewski Physics in Medicine & Biology 62 (9), 3712, 2017 | 91 | 2017 |
Self-calibration of cone-beam CT geometry using 3D–2D image registration S Ouadah, JW Stayman, GJ Gang, T Ehtiati, JH Siewerdsen Physics in Medicine & Biology 61 (7), 2613, 2016 | 89 | 2016 |
Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery Y Otake, S Schafer, JW Stayman, W Zbijewski, G Kleinszig, R Graumann, ... Physics in Medicine & Biology 57 (17), 5485, 2012 | 84 | 2012 |
Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction AS Wang, JW Stayman, Y Otake, G Kleinszig, S Vogt, GL Gallia, ... Physics in Medicine & Biology 59 (4), 1005, 2014 | 77 | 2014 |
Extra‐dimensional Demons: a method for incorporating missing tissue in deformable image registration S Nithiananthan, S Schafer, DJ Mirota, JW Stayman, W Zbijewski, DD Reh, ... Medical physics 39 (9), 5718-5731, 2012 | 73 | 2012 |
PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction JW Stayman, H Dang, Y Ding, JH Siewerdsen Physics in Medicine & Biology 58 (21), 7563, 2013 | 71 | 2013 |
Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise S Tilley, JH Siewerdsen, JW Stayman Physics in Medicine & Biology 61 (1), 296, 2015 | 70 | 2015 |